Dell PowerEdge C6220 II Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel informatique Dell PowerEdge C6220 II. Dell PowerEdge C6220 II User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Management Controller

FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_tp.fmTemplate Last Updated -03/06/2010Dell PowerEdgeC6220 IIUsing the B

Page 2 - ____________________

10FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmPropertiesThe Properties option enables you to view the re

Page 3 - Contents

11FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmChassisThe Chassis option enables you to view a summary ch

Page 4 - 4 Contents

12FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmConfiguration The Configuration option enables you to view

Page 5 - Interface

13FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-4. NetworkItem DescriptionGeneral SettingsMode Sel

Page 6 - Using the Web User Interface

14FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmSecuritySelect the Security submenu to view server certifi

Page 7

15FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmIssuer Information:Country Code (CC) Country that issued t

Page 8

16FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmUsersSelect the Users submenu to view the list of users au

Page 9 - Remote Management Controller

17FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmUser ID Column Displays a list of users who can access thi

Page 10 - Properties

18FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmServicesSelect the Services submenu to view the communicat

Page 11 - Item Description

19FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmIPMISelect the IPMI submenu to view the IPMI-based communi

Page 12 - Configuration

FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_tp.fm NOTE: A NOTE indicates important information that helps you make

Page 13

20FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmSessionsThe Sessions option enables you to view sessions c

Page 14 - Security

21FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmUpdate The Update option enables users with administrator

Page 15

22FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmUpdating the BMC Firmware CAUTION: Before beginning the f

Page 16

23FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm5Click Update. When the update is completed, the remote sy

Page 17

24FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmServer Information The Server Information menu enables use

Page 18 - Services

25FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmVoltagesSelect Voltages from the Sensor Type drop-down men

Page 19 - IPMI settings

26FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-13. Voltages Sensor ReadingsItems DescriptionGener

Page 20 - Sessions

27FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmPower Supplies Select Power Supplies from the Sensor Type

Page 21

28FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmBatteries Select Batteries from the Sensor Type drop-down

Page 22 - Updating the BMC Firmware

29FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmFansSelect Fans from the Sensor Type drop-down menu to vie

Page 23 - Utilities

FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_bk0TOC.fmContents3ContentsIntelligent Platform Management Interface . .

Page 24 - Server Information

30FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTemperaturesSelect Temperatures from the Sensor Type drop-

Page 25 - Voltages

31FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-17. Temperature Sensor ReadingsItems DescriptionGe

Page 26

32FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmPower The Power option enables you to view the server’s po

Page 27 - Power Supplies

33FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmSystem Event LogThe System Event Log menu enables users wi

Page 28 - Batteries

34FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmEvent ManagementThe Event Management option enables users

Page 29

35FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-20. Platform Event FiltersItems DescriptionPlatfor

Page 30 - Temperatures

36FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm NOTE: BMC event log “Processor #0x1c” or “Processor #0x1

Page 31

37FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmEmail SettingsSelect the Email Settings submenu to view em

Page 32

38FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-22. Email SettingsItems DescriptionSender Informat

Page 33 - System Event Log

39FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmSTARTTLS modeSelect a Start Transport Layer Security (Star

Page 34 - Event Management

FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_bk0TOC.fm4 ContentsSerial Over LAN . . . . . . . . . . . . . . . . . .

Page 35

40FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmSerial Over LANThe Serial over LAN menu enables users with

Page 36 - Trap Settings

41FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmvKVM & vMedia The vKVM & vMedia option enables the

Page 37 - Email Settings

42FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmConsole RedirectionThe most powerful feature of the Remote

Page 38

43FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTo start a remote console session from the Virtual KVM and

Page 39

44FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmPreferred Client TypeSelect a client application to use fo

Page 40 - Serial Over LAN

45FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmUsing the Video ViewerThe Video Viewer provides a user int

Page 41

46FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmVideo Viewer MenuThe Video Viewer menu provides access to

Page 42 - Console Redirection

47FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-29. Tools Menu ItemsMenu Option DescriptionSession

Page 43

48FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-31. Help Menu ItemsMenu Option DescriptionContents

Page 44

49FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmIPMI 1.5/2.0 Command Support ListThe IPMItool program prov

Page 45 - Using the Video Viewer

Template Last Updated - 2/7/2007 5Intelligent Platform Management InterfaceThe Intelligent Platform Management Interface (IPMI) defines a set of stand

Page 46 - Video Viewer Menu

50FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-32. IPMI Device Global Commands (NetFn: 0x06H)Comm

Page 47

51FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-33. BMC Device and Messaging Commands (NetFn: 0x06

Page 48 - Menu Option Description

52FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-34. BMC Device and Messaging Commands (NetFn: 06H)

Page 49

53FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-36. Chassis Device Commands (NetFn: 00H)Command Ne

Page 50

54FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-38. Sensory Device Commands (NetFn: 04H)Command Ne

Page 51

55FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm* Support for Partial Add SEL is not required when Add SEL

Page 52 - (continued)

56FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-42. SDR Repository Commands (NetFn: 0AH)Command Ne

Page 53

57FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-44. Serial/Modem Device Commands (NetFn: 0CH)Comma

Page 54

58FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Reset Peripheral Device Controller Byte Order and Field F

Page 55

59FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm Get Peripheral Device Controller Reset Status Command Byt

Page 56

6FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm• Platform Event Filtering (PEF) to take selected action fo

Page 57

60FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmThreshold Settings and Converting FormulasThe following ta

Page 58

61FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmTable 1-50. Threshold Settings and Converting Formulas (co

Page 59

62FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm

Page 60

7FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmLogging in to the Web User InterfaceUsers must enter the Po

Page 61

8FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fm NOTE: The default username and password are in lowercase

Page 62

9FILE LOCATION: D:\Projects\User Guide\Server\Dell\C6220II\BMC\C6220II_BMC_HOM_section1.fmRemote Management Controller The Remote Management Controll

Commentaires sur ces manuels

Pas de commentaire