Dell FORCE10 Open Automation Manuel d'utilisateur Page 68

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 98
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 67
68 | Virtual Server Networking CLI
www.dell.com | support.dell.com
type
Set the hypervisor type to which you want to connect.
Syntax
[no] type {vmware | xen-citrix}
Defaults
None
Parameters
Command Modes
HYPERVISOR
Usage
Information
You must configure a hypervisor type in order to enable VSN connections with
virtual servers. Use the
show hypervisor supported command to display the currently
supported hypervisor types.
Command
History
vsn enable
Enable VSN on an interface.
Syntax
[no] vsn enable
Defaults
VSN is disabled by default on switch interfaces.
Command Modes
INTERFACE
Command
History
Usage
Information
Enter the vsn enable command only on hypervisor-facing interfaces. DO NOT enter
this command on an interface used for inter-switch links.
Enter the
no vsn enable command to remove the VSN configuration from the system.
You must reconfigure VSN to re-enable a hypervisor session.
vmware Set the hypervisor type as VMware.
xen-citrix Set the hypervisor type as Xen-Citrix.
Version 8.3.8.0 Introduced on the S4810.
Version 8.3.5.1 Introduced on the S55.
Version 8.3.3.4 Introduced on the S60.
Version 8.3.8.0 Introduced on the S4810.
Version 8.3.5.1 Introduced on the S55.
Version 8.3.3.4 Introduced on the S60.
Vue de la page 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 97 98

Commentaires sur ces manuels

Pas de commentaire