22 M5424 SAN I/O Module Hardware Reference Manual
53-1001082-01
Interpreting LED activity
3
Interpreting LED activity
Each SAN I/O Module uses LEDs to indicate status. These LEDs are shown in Figure 5.
FIGURE 5 LED Locations
TABLE 4 Key to Figure 5
Location Indicator Color Operation
1FC (external)
port status
green/amber Note: LED meanings are not valid during boot, diagnostics,
or POST.
Green:
Off (dark): No signal carrier or unlicensed.
Steady: Online normal active port but no port activity.
Flickering: normal active port (I/O activity).
Slow blink: Online but segmented.
Fast blink: Internal loopback.
Amber
Steady: Signal present but not online.
Slow blink or flash: Disabled port (less than two second
interval).
Fast (rapid) blink or flash: Error or fault with port (less than
1/2 second interval).
2 (status icon)
and 3 (LED)
module
status
green/amber Off:
SAN I/O Module is off or power supplies for the Blade Server
or onboard DCC have failed.
Green:
No errors and all ports are ready for use.
Amber:
Steady: Boot-up state, port(s) offline, or in reset state.
Blinking (green/amber): One or more environmental ranges
are exceeded, or error log contains diagnostic error
messages.
Note: The LED might blink during testing.
4 (icons) and 5
(LED)
module
power
green Off:
SAN I/O Module is off or power supplies for the Blade Server
Enclosure or onboard DCC have failed.
Green: Normal operation and power supply is functioning.
properly. Power is supplied by the Blade Server Enclosure.
6 (icon) 7
(LED)
server
management
blue/amber Controlled by the Blade Server Enclosure's CMC. For details,
refer to the Hardware Owner’s Manual for Blade Server
Enclosure.