MODE SELECT 6 (15h)
The MODE SELECT (6) command provides a means for the host to specify peripheral device parameters
to the media changer. Application clients should issue MODE SENSE prior to each MODE SELECT to
determine supported pages, page lengths, changeable variables and to determine is the page is savable
to NVRAM.
Bit 7 6 5 4 3 2 1 0
Byte
0 Operation Code (15h)
1 LUN PF (1) Reserved SP
2 Reserved
3 Reserved
4 Parameter list length
5 Control
Field descriptions:
PF: A PF bit of one indicates that the MODE SELECT parameters following the header and block
descriptor(s) complies with the SCSI-2 specification. The value must be set to 1.
SP: A Save Pages (SP) bit of zero indicates the media changer shall perform the specified MODE
SELECT operation, and shall not save any pages in nonvolatile ram. An SP bit of one indicates
that the media changer shall perform the specified MODE SELECT operation, and shall save the
current values to a nonvolatile RAM.
When a host has successfully issued the MODE SELECT CDB that changed settings in one of the Mode
pages, the media changer will raise a Unit Attention condition to every other host who has not issued this
CDB. The sense data for these hosts will be set to: Mode Parameters Changed (06/2A/01)
The host provides the parameters through a parameter list to the media changer. The parameter list
consists of the following items:
v Parameter List Header
v Mode Select page(s)
Supported Mode Select pages:
Page
Code
Subpage
Code
Page Name Page
saveable in
NVRAM
Page Description
00h 00h Parity Retry page Yes Provides means to select the maximum number
retries performed on a parity error.
0Ah 01h Control Extension page No Provides a means to read out the capabilities of
the SET TIMESTAMP and REPORT TIMESTAMP
commands.
1Ch 00h Tape Alert page No Provides means to select a specific way to report
a Tape Alert event .
1Dh 00h Element Address
Assignment page
Yes Provides a means to change SCSI element
address assignments and respective element
ranges.
1Eh 00h Transport Geometry
page
No Provides a means to set the specifics about the
Transport Element. (not changeable).
Chapter 3. Supported SCSI Commands 3-21