28 About Your System
Sector not found.
Seek error.
Seek operation
failed.
Faulty hard drive, USB
device or medium.
Replace the USB medium or
device. Ensure that the USB
cables are properly connected.
See "Troubleshooting a USB
Device" on page 106 or
"Troubleshooting a Hard
Drive" on page 117 for the
appropriate drive(s) installed
in your system.
Shutdown
failure.
General system error. See "Getting Help" on
page 129.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed, check
the SEL to determine if single-
bit or multi-bit errors were
detected and replace the faulty
memory module. See
"Troubleshooting System
Memory" on page 113.
Message Causes Corrective Actions