42 | Specifications
www.dell.com | support.dell.com
DC Power Requirements
IEEE Standards
The S4810 complies with the following IEEE standards:
• 802.3ae 10 Gigabit Ethernet
• 802.3ab 1000Base-T
• 802.1p L2 Prioritization
• 802.1Q VLAN Tagging, Double VLAN Tagging (Q in Q), GVRP
• 802.1s Multiple Spanning Tree Protocol
• 802.1w Rapid Spanning Tree Protocol
• 802.3ad Link Aggregation with LACP
• 802.1D Bridging, GARP, GMRP
• 802.3x Flow Control
• 802.1ac Frame Extension for VLAN Tagging
• 802.1x Port Based Network Access Control
Agency Compliance
Network Equipment Building Systems (NEBS) Compliance
• Use shielded cables for ports 0 - 43. You must ground the shields at both ends.
• Use only reverse airflow configurations in a NEBS-compliant installation. Use only AC supply
S55-PWR-AC-R, DC supply S55-PWR-DC-R and Fan Only S55-FAN-R, Systems S55-44T-AC-R and
S55-44T-DC-R.
• Fit the power supplies and fan modules with filter kits (S55-PWR-FLTR). You must replace the fan
filters on a regular basis.
• Use this equipment with an external, second-level 6kV lightning Surge Protective Device (SPD) at the
AC input of the building.
Parameter Specifications
Nominal input voltage 36 to 72 VDC
Maximum power supply input current 2.8A @ 36 VDC
1.85 A @ 72 VDC
Maximum system power input 360 W