Dell OpenManage Server Administrator Version 7.4 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Cartes mères Dell OpenManage Server Administrator Version 7.4. Dell OpenManage Server Administrator Version 7.4 SNMP Reference Guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 557
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Dell OpenManage
SNMP Reference Guide Version 7.4
Vue de la page 0
1 2 3 4 5 6 ... 556 557

Résumé du contenu

Page 1 - Dell OpenManage

Dell OpenManageSNMP Reference Guide Version 7.4

Page 2 - Notes, Cautions, and Warnings

See Physical Memory Array Table for more information.– Added the following new varbind for:Baseboard Management Controller Group * Added new MIB varbi

Page 3 - Contents

Description Defines the share disposition of the system resource DMA.Syntax DellResourceShareDisposition (Resource Share Disposition)Access Read-on

Page 4

Table 326. Resource Owner Interface TypeVariable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value ty

Page 5

memoryIsF24(16)The resource memory is F24.Table 329. Resource Interrupt TypeVariable Name: DellResourceInterruptType Data Type: Integer Possible Data

Page 6

dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits.dmaTransferWidthIs64Bits(6

Page 7

Access Read-onlyIndex powerUnitchassisIndex, powerUnitIndexTable 335. Power Unit Chassis IndexName powerUnitchassisIndexObject ID 1.3.6.1.4.1.674.1

Page 8

Table 340. Power Supply Count for RedundancyName powerSupplyCountForRedundancyObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.6Description Defines the to

Page 9 - Introduction

Table 345. Power Supply Chassis IndexName powerSupplychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.1Description Defines the index (one-base

Page 10 - Supported SNMP Versions

Table 350. Power Supply Output WattsName powerSupplyOutputWattsObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.6Description Defines the maximum sustained

Page 11

Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply.Syntax DellPowerSupply

Page 12

Description Defines the Voltage Probe Table entry.Syntax VoltageProbeTableEntryAccess Not accessibleIndex voltageProbechassisIndex, voltageProbeIn

Page 13

MIB Name Agent / Hardware Supported Purpose of the MIBinstrumentation software. This is the primary MIB for PowerEdge systems.dcs3fru.mib Server Admin

Page 14

Access Read-onlyTable 366. Voltage Probe ReadingName voltageProbeReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.6Description Defines the value o

Page 15

Access Read-onlyTable 371. Voltage Probe Upper Noncritical ThresholdName voltageProbeUpperNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.2

Page 16 - Basic Terminology

Table 376. Voltage Probe Discrete ReadingName voltageProbeDiscreteReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.16Description Defines the readin

Page 17 - Table 12. UUID Type

Description Defines the index of amperage probes in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 381. Amperage Probe State Capabilities

Page 18 - Other Documents You May Need

amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps.When the value for ampera

Page 19

Description Defines the user-assigned value of the amperage probe’s upper critical threshold.Syntax DellSigned32BitRangeAccess Read-onlyTable 390.

Page 20 - SNMP Security

When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperag

Page 21 - SNMP Traps

Table 399. AC Power Switch CapabilitiesName aCPowerSwitchCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.40.1.3Description Defines the capabilitie

Page 22

Description Defines the redundancy mode of this AC power switch.Syntax DellACPowerSwitchRedundancyModeAccess Read-onlyTable 405. AC Power Switch St

Page 23 - Server Administrator Group

Table 409. AC Power Cord IndexName aCPowerCordIndexObject ID 1.3.6.1.4.1.674.10892.1.600.42.1.2Description Defines the index (one-based) of this AC

Page 24

group number>, where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information abou

Page 25 - Systems Management Software

Description Defines the location name of this AC power cord.Syntax DellStringAccess Read-onlyBattery TableTable 415. Battery TableName batteryTable

Page 26

Access Read-onlyTable 420. Battery State SettingsName batteryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.4Description Defines the state

Page 27

Table 425. Power Usage Table EntryName powerUsageTableEntryObject ID 1.3.6.1.4.1.674.10892.1.600.60.1Description Defines the Power Usage Table Entry

Page 28 - System State Group

Table 430. Power Usage StatusName powerUsageStatusObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.5Description Defines the status of the power usage info

Page 29

Table 435. Power Usage Peak Watts Start Date NameName powerUsagePeakWattsStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.10Description Defin

Page 30 - System State Table

Table 440. Power Usage Idle PowerName powerUsageIdlePowerObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.15Description Defines the system idle power (in

Page 31

Table 445. Power Usage Instantaneous HeadroomName powerUsageInstantaneousHeadroomObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.20Description Defines th

Page 32

Table 450. Power Profile IndexName powerProfileIndexObject ID 1.3.6.1.4.1.674.10892.1.600.70.1.2Description Defines the index (one-based) of the pow

Page 33

Table 455. Power Profile Custom Memory Management CapabilitiesName powerProfileCustomMemoryManagementCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.60

Page 34

onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).notReadyCapable(4) The power suppl

Page 35

Section Topics MIB Group Numbers18 Cost of Ownership Group — defines variables for tracking data on the system’s service contract, lease, repair reco

Page 36

powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply.powerSupplyTypeIsBattery(5)The power supply type is a battery.powerSup

Page 37

processorMissing(3)The power supply configuration error type is processor missing.Table 464. Voltage Probe TypeVariable Name: DellVoltageType Data Typ

Page 38

Table 466. Amperage Probe DefinitionsVariable Name: DellAmperageType Data Type: IntegerPossible Data Values Meaning of Data Value amperageProbeTypeIs

Page 39

amperageProbeTypeIsSystemWatts(26) The amperage probe type is system probe with reading in Watts.Table 467. Amperage Probe Discrete ReadingVariable Na

Page 40

nonRedundant(1) The AC power switch is not expecting redundancy.redundant(2)The AC power switch is expecting redundancy.Table 471. AC Power Cord State

Page 41

NOTE: These values are bit masks, so combination values are possible.Possible Data Values Meaning of Data Value none(0) No power cap capabilities are

Page 42

systemDBPM(8) CPU power and performance management type is System Demand Based Power Management.Table 478. Memory Power Performance Management TypeVar

Page 43

• Temperature Probe TableCooling Unit TableTable 480. Cooling Unit TableName coolingUnitTableObject ID 1.3.6.1.4.1.674.10892.1.700.10Description Def

Page 44 - Chassis Information Group

Access Read-onlyTable 485. Cooling Unit State SettingsName coolingUnitStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.4Description Defines

Page 45 - Chassis Information Table

Cooling Device TableTable 490. Cooling Device TableName coolingDeviceTableObject ID 1.3.6.1.4.1.674.10892.1.700.12Description Defines the Cooling De

Page 46 - Table 97. Chassis Type

1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant se

Page 47

Access Read-onlyTable 495. Cooling Device State SettingsName coolingDeviceStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.4Description Defi

Page 48

Access Read-onlyTable 500. Cooling Device Upper Nonrecoverable ThresholdName coolingDeviceUppernonrecoverableThresholdObject ID 1.3.6.1.4.1.674.1089

Page 49

Table 505. Cooling Device Lower Nonrecoverable ThresholdName coolingDeviceLowerNonRecoverableThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.14De

Page 50

Temperature Probe TableTable 510. Temperature Probe TableName temperatureProbeTableObject ID 1.3.6.1.4.1.674.10892.1.700.20Description Defines the T

Page 51

Access Read-onlyTable 515. Temperature Probe State SettingsName temperatureProbeStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.4Description

Page 52

Syntax DellStringAccess Read-onlyTable 520. Temperature Probe Upper Nonrecoverable ThresholdName temperatureProbeUpperNonRecoverableThresholdObject

Page 53

Access Read-onlyTable 525. Temperature Probe Lower Nonrecoverable ThresholdName temperatureProbeLowerNonRecoverableThresholdObject ID 1.3.6.1.4.1.67

Page 54

coolingDeviceTypeIsABlower(4)The cooling device type is a centrifugal blower.coolingDeviceTypeIsAChipFan(5)The cooling device type is a fan on an inte

Page 55 - UUID Table

Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1)The temperature probe subtype is not one of the following:temperatureProbeTy

Page 56 - POST Log Table

Access Not accessibleIndex remoteFlashBIOSchassisIndex, remoteFlashBIOSIndexTable 535. Remote Flash BIOS Chassis IndexName remoteFlashBIOSchassisInd

Page 57 - Table 148. POST Log Table

Table 5. Server Administrator Change Management MIB Sections in This GuideSection Topics MIB Group Number24 Change Management Group - describes the i

Page 58 - Event Log Table

Table 539. Remote Flash BIOS StatusName remoteFlashBIOSStatusObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.5Description Defines the status of the remot

Page 59

unknown(1) The remote flash BIOS’s capabilities are unknown.enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enab

Page 60 - System BIOS Table

completionCodeIsNoExternalPower(10) An external power adapter must be connected.completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set.completi

Page 61 - Table 169. System BIOS Index

Description Defines the Pointing Port Table entry.Syntax PointingPortTableEntryAccess Not accessibleIndexpointingPortchassisIndex,pointingPortIndexTab

Page 62 - Table 173. System BIOS Size

Table 552. Pointing Port StatusNamepointingPortStatusObject ID 1.3.6.1.4.1.674.10892.1.1000.10.5Description Defines the status of the pointing port.Sy

Page 63

Keyboard Port TableTable 557. Keyboard Port TableName keyboardPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.20Description Defines the Keyboard Port

Page 64

Description Defines the capabilities of the keyboard port.Syntax DellStateCapabilitiesAccess Read-onlyTable 562. Keyboard Port State SettingsName keyb

Page 65

Syntax DellStringAccess Read-onlyTable 567. Keyboard Port BIOS Connector TypeName keyboardPortBIOSConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.

Page 66 - Firmware Table

Table 571. Processor Port IndexNameprocessorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2Description Defines the index of the processor ports

Page 67 - Table 189. Firmware Size

Table 576. Processor Port Connector TypeNameprocessorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7Description Defines the connector t

Page 68 - Intrusion Table

Basic TerminologyIt is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all e

Page 69 - Table 198. Intrusion Index

IndexmemoryDevicePortchassisIndex,memoryDevicePortIndexTable 581. Memory Device Port Chassis IndexNamememoryDevicePortchassisIndexObject ID 1.3.6.1.4.

Page 70 - Baseboard Table

Syntax DellStatusAccess Read-onlyTable 586. Memory Device Port Security StateNamememoryDevicePortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.4

Page 71 - Table 208. Baseboard Index

Syntax DellUnsigned32BitRangeAccess Read-onlyTable 591. Memory Device Port Physical Memory Card Index ReferenceNamememoryDevicePortPhysicalMemoryCardI

Page 72

Table 595. Monitor Port IndexName monitorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2Description Defines the index of the monitor ports in t

Page 73

Table 600. Monitor Port Connector TypeName monitorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7Description Defines the connector type

Page 74 - Table 224. Chassis Type

,sCSIPortIndexTable 605. SCSI Port Chassis IndexNamesCSIPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1Description Defines the index (on

Page 75 - Table 225. Connection Status

Access Read-onlyTable 610. SCSI Port Security StateNamesCSIPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6Description Defines the secur

Page 76

Access Not accessibleTable 615. Parallel Port Table EntryNameparallelPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1Description Defines the

Page 77

Description Defines the state and settings of the parallel port.Syntax DellStateSettingsAccess Read-onlyTable 620. Parallel Port StatusNameparallelPor

Page 78

Syntax DellParallelPortConnectorPinoutAccess Read-onlyTable 625. Parallel Port Capabilities UniqueNameparallelPortCapabilitiesUniqueObject ID 1.3.6.1.

Page 79

Table 8. UUID TableName uUIDTableObject ID 1.3.6.1.4.1.674.10892.1.300.20Description Defines the UUID table.Syntax SEQUENCE OF UUIDTableEntryAccess

Page 80

Syntax IntegerSerialPortTableEntryAccess Not accessibleTable 630. Serial Port Table EntryNameserialPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.100

Page 81 - Table 241. System Properties

Table 634. Serial Port State SettingsNameserialPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4Description Defines the state and setting

Page 82 - Table 243. Baseboard Type

Table 639. Serial Port Maximum SpeedNameserialPortMaximumSpeedObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9Description Defines the maximum speed the s

Page 83 - Table 245. Firmware Type

Access Not accessibleTable 644. USB Port Table EntryNameuSBPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1Description Defines the USB Port T

Page 84

Access Read-onlyTable 649. USB Port StatusNameuSBPortStatusObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5Description Defines the state of the USB port.

Page 85

connectorPortTypeIsOther(1)The pointing port connector type is not one of the following:connectorPortTypeIsUnknown(2)The pointing port connector type

Page 86

connectorPortTypeIsAccessBusUSB(9)The keyboard port connector type is bus USB.connectorPortTypeIsPC98(10)The keyboard port connector type is PC-98.Tab

Page 87 - System Resource Group

connectorPortTypeIsZIP(7)The memory device port connector type is a ZIP.connectorPortTypeIsAProprietaryCard(8)The memory device port connector type is

Page 88

about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.Device TablesThe following manageme

Page 89 - System Resource Owner Table

Table 661. Pointing Device Chassis IndexNamepointingDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1Description Defines the index (one-

Page 90

Access Read-onlyTable 13. UUID ValueName uUIDValueObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.4Description Defines the value of the UUID for this ch

Page 91

Description Defines the index to the pointing port in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 667. Pointing Device TypeNamepointingDe

Page 92

Table 671. Keyboard Device Chassis IndexNamekeyboardDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1Description Defines the index (one-

Page 93 - System Resource Memory Table

Description Defines the index to the associated the keyboard port in this chassis.Syntax DellStatusAccess Read-onlyTable 677. Keyboard Device Type Nam

Page 94

Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 682. Processor Device IndexNameprocessorDeviceIn

Page 95

Table 687. Processor Device TypeNameprocessorDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7Description Defines the type of processor device.S

Page 96

Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown.Syntax DellUnsigned32BitRangeAcce

Page 97

Description Defines the number of processor cores detected for the processor device.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 698. Processor

Page 98

Table 701. Processor Device Extended CapabilitiesNameprocessorDeviceExtendedCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21Description This

Page 99

Table 704. Processor Device Model NameNameprocessorDeviceModelNameObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24Description Defines the model of the p

Page 100

Table 709. Processor Device Status IndexNameprocessorDeviceStatusIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2Description Defines the index (one-

Page 101

• The Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object f

Page 102

Description Defines the location name of the processor device status probe.Syntax DellStringAccess Read-onlyTable 715. Processor Device Status Port In

Page 103 - Power Group

Table 719. Cache Device IndexNamecacheDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2Description Defines the index of the cache device in thi

Page 104 - Table 336. Power Unit Index

Description Defines the type of cache device.Syntax DellCacheDeviceType (See Cache Device Type)Access Read-onlyTable 725. Cache Device LocationNamecac

Page 105 - Power Supply Table

Access Read-onlyTable 730. Cache Device Current SizeNamecacheDeviceCurrentSizeObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13Description Defines the cu

Page 106 - Table 346. Power Supply Index

Table 735. Cache Device AssociativityNamecacheDeviceAssociativityObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18Description Defines the type of associa

Page 107

,memoryDeviceIndexTable 740. Memory Device Chassis IndexNamememoryDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1Description Defines t

Page 108 - Voltage Probe Table

Table 745. Memory Device Memory Port Index ReferenceNamememoryDeviceMemoryPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6Description D

Page 109

Access Read-onlyTable 750. Memory Device Type DetailsNamememoryDeviceTypeDetailsObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11Description Defines the

Page 110 - Table 367. Voltage Probe Type

Access Read-onlyTable 755. Memory Device Total Bus WidthNamememoryDeviceTotalBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16Description Defines

Page 111

Table 759. Memory Device Failure ModesNamememoryDeviceFailureModesObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20Description Defines the failure modes

Page 112 - Amerage Probe Table

Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates

Page 113

Management Information Base Object IdentifiersEach data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OID

Page 114

Table 764. Memory Device Speed NameNamememoryDeviceSpeedNameObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25Description This attribute defines the speed

Page 115

Access Not accessibleTable 768. Memory Device Mapped Address Table EntryNamememoryDeviceMappedAddressTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.

Page 116 - AC Power Switch Table

Syntax DellStateSettingsAccess Read-onlyTable 773. Memory Device Mapped Address StatusNamememoryDeviceMappedAddressStatusObject ID 1.3.6.1.4.1.674.108

Page 117

Syntax DellUnsigned32BitRangeAccess Read-onlyTable 778. Memory Device Mapped Address Starting AddressNamememoryDeviceMappedAddressStartingAddressObjec

Page 118 - AC Power Cord Table

Table 782. Generic Device Chassis IndexNamegenericDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1Description Defines the index (one-ba

Page 119

Description Defines the index of the system slot into which this generic device is plugged.Syntax DellObjectRangeAccess Read-onlyTable 788. Generic De

Page 120 - Battery Table

Table 792. PCI Device Chassis IndexNamepCIDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1Description Defines the index (one-based) of

Page 121 - Power Usage Table

Description Defines the index number of the system slot that this PCI device is in.Syntax DellObjectRangeAccess Read-onlyTable 798. PCI Device Data Bu

Page 122 - Table 427. Power Usage Index

PCI Device Configuration Space TableTable 803. PCI Device Configuration Space TableNamepCIDeviceConfigurationSpaceTableObject ID 1.3.6.1.4.1.674.10892

Page 123 - Table 430. Power Usage Status

Access Read-onlyTable 808. PCI Device Configuration Space State SettingsNamepCIDeviceConfigurationSpaceStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.

Page 124

system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this securit

Page 125

Table 813. PCI Device Configuration Space Function NumberNamepCIDeviceConfigurationSpaceFunctionNumberObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9Des

Page 126 - Power Profile Table

Access Read-onlyTable 818. Network Device IndexNamenetworkDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2Description Defines the index (one-b

Page 127

Table 823. Network Device Vendor NameNamenetworkDeviceVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7Description Defines the name of the vendo

Page 128 - Power Group Variable Values

Description Defines the IP subnet mask for the IP address currently assigned to the network device.Syntax IpAddressAccess Read-onlyTable 829. Network

Page 129

Syntax DellUnsigned8BitRangeAccess Read-onlyTable 834. Network Device PCI Device NumberNamenetworkDevicePCIDeviceNumberObject ID 1.3.6.1.4.1.674.10892

Page 130

Table 839. Network Device TOE Capability FlagsNamenetworkDeviceTOECapabilityFlagsObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23Description Defines the

Page 131 - Table 464. Voltage Probe Type

Table 844. Network Device iSCSI EnabledNamenetworkDeviceiSCSIEnabledObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28Description Defines if iSCSI is enab

Page 132

Access Read-onlyTable 849. Managed System Services Device StatusNamemanagedSystemServicesDeviceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3Des

Page 133

Access Not accessibleTable 854. SD Card Unit Table EntryNamesdCardUnitTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.110.1Description Defines the SD

Page 134 - Table 473. Battery Reading

Access Read-onlyTable 859. SD Card Unit Redundancy StatusNamesdCardUnitRedundancyStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5Description Defin

Page 136 - Thermal Group

Table 864. SD Card Device Table EntryNamesdCardDeviceTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1Description Defines the SD Card Device Tabl

Page 137 - Cooling Unit Table

Table 869. SD Card Device Config CapabilitiesNamesdCardDeviceConfigCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5Description Defines the c

Page 138 - Table 488. Cooling Unit Name

Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 875. S

Page 139 - Cooling Device Table

deviceTypeIsATrackBall(4)Device type is a track ball.deviceTypeIsATrackPoint(5)Device type is a track point.deviceTypeIsAGlidePoint(6)Device type is a

Page 140

Data Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)The processor device type is not one of the following values:deviceType

Page 141

processorUpgradeIsBySlotM(12)Upgrade is by Slot M.processorUpgradeIsByScoket423(13)Upgrade is by Socket 423.processorUpgradeIsBySocketA(14)Upgrade is

Page 142

deviceFamilyIs80286(4)The processor family is 80286.deviceFamilyIs80386(5)The processor family is 80386.deviceFamilyIs80486(6)The processor family is

Page 143 - Temperature Probe Table

deviceFamilyIsK6(26)The processor family is K6.deviceFamilyIsK6-2(27)The processor family is K6-2.deviceFamilyIsK6-3(28)The processor family is K6-3.d

Page 144

deviceFamilyIsAlpha21164(51) The processor family is Alpha 21164.deviceFamilyIsAlpha21164PC(52)The processor family is Alpha 21164PC.deviceFamilyIsAlp

Page 145

deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II.deviceFamilyIsmicroSPARCIIep (83)The processor family is microSPARC IIep.deviceFa

Page 146 - Thermal Group Variable Values

2Server Administrator GroupThe Server Administrator group comprises of the following sections:• Instrumentation MIB Version Group• Systems Management

Page 147

deviceFamilyIsAMDTurion64Mobile(134) The processor family is AMD Turion 64 Mobile Technology.deviceFamilyIsDualCoreAMDOpter on(135)The processor famil

Page 148 - Remote Flash BIOS Group

deviceFamilyIsQuadCoreIntelXeon3200(161)The processor family is Quad-Core Intel Xeon processor 3200 Series.deviceFamilyIsDualCoreIntelXeon3000(162)The

Page 149

deviceFamilyIsM2(177)The processor family is M2.deviceFamilyIsIntelPentium4HT (179)The processor family is Intel Pentium 4 HT processor.deviceFamilyIs

Page 150

deviceFamilyIsIntelCorei7(198)The processor family is Intel Core i7 processor.deviceFamilyIsDualCoreIntelCel eron(199)The processor family is Dual-Cor

Page 151

deviceFamilyIsDualCoreIntelXeo n7xxx(221)The processor family is Dual-Core Intel Xeon processor 7xxx Series.deviceFamilyIsQuadCoreIntelXeo n7xxx(222)T

Page 152 - Port Group

deviceFamilyIsAMDOpteron4200 (61)The processor family family is AMD Opteron 4200 Series Processor.Table 884. Cache Device TypeVariable Name:DellCacheD

Page 153

deviceWritePolicyIsWriteThrough(4)Device write policy is write through.deviceWritePolicyIsVariesByAddress(5)Device write policy varies by address.devi

Page 154 - Table 555. Pointing Port Name

deviceAssociativityIsOther(1)Device associativity is not one of the following:deviceAssociativityIsUnknown(2)Device associativity is unknown.deviceAss

Page 155 - Keyboard Port Table

deviceLocationIsInternal(3)Device location is internal.deviceLocationIsExternal(4)Device location is external.Table 891. Cache Device Static Random-Ac

Page 156 - Table 566. Keyboard Port Name

deviceFormFactorIsAProprietaryCard(8)Device form factor is a proprietary card.deviceFormFactorIsDIMM(9) Device form factor is DIMM.deviceFormFactorIsT

Page 157 - Processor Port Table

Description Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version

Page 158

deviceTypeIsEPROM(12)Device type is EPROM.deviceTypeIsCDRAM(13)Device type is CDRAM.deviceTypeIs3DRAM(14)Device type is 3DRAM.deviceTypeIsSDRAM(15)Dev

Page 159 - Memory Device Port Table

deviceTypeDetailIsCMOS(256) The detailed device type is CMOS.deviceTypeDetailIsEDO(512) The detailed device type is EDO.deviceTypeDetailIsWindowDRAM (

Page 160

(0)Memory device has no faults.eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate.eccSingleBitC

Page 161

noTeam(1)Device is not part of any team.teamingEnabled(2)Teaming is enabled.adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.loadBala

Page 162 - Monitor Port Table

Table 901. Network Device iSCSI Capability FlagsVariable Name:DellNetworkDeviceiSCSICapabilityFlagsData Type:IntegerNOTE: These values are bit fields,

Page 163 - Table 595. Monitor Port Index

none(0)SD card device has none of the following capabilities.sdCapable(1)SD media can be enabled.vFlashCapable(2)Virtual Flash (vFlash) can be enabled

Page 164 - Table 601. Monitor Port Name

offline(8)Device is offline.failed(16)Device is failed.active(32)Device is active.bootable(64)Device is bootable.writeProtect(128)Device is write-prot

Page 165 - Table 609. SCSI Port Status

Syntax DellObjectRangeAccess Read-onlyTable 911. System Slot IndexName systemSlotIndexObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2Description Def

Page 166 - Parallel Port Table

Access Read-onlyTable 916. System Slot TypeName systemSlotTypeObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7Description Defines the type of the syst

Page 167

Access Read-onlyTable 921. System Slot Hot-Plug Bus WidthName systemSlotHotPlugBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12Description De

Page 168 - Table 623. Parallel Port Name

To manage a system locally using Server Administrator, type the following in the address field of your browser: https://localhost:<1311 or user-spe

Page 169 - Serial Port Table

systemSlotHotPlugCanSignal Attention(8) The system slot attention state (and corresponding LED) can be set.systemSlotHotPlugCanSignal PowerFault(16) P

Page 170 - Table 632. Serial Port Index

systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on.systemSlotHotPlugHasPowerFaulted (16) Power on fault (

Page 171 - Table 638. Serial Port Name

systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA).systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA).syst

Page 172

systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express Gen 2.systemSlotIsPCIExpressGen2X1(172) The system slot type is PCI Express Gen 2

Page 173 - Table 646. USB Port Index

Table 930. Hot-Plug Bus WidthVariable Name: DellSystemSlotHotPlugBusWidth Data Type: IntegerPossible Data Values Meaning of Data Value busWidthIsOthe

Page 174 - Port Group Variable Values

Physical Memory Array TableThe physical memory array is the entire physical memory of a system. The example that follows shows variable values for a s

Page 175

Syntax DellObjectRangeAccess Read-onlyTable 934. Physical Memory Array IndexName physicalMemoryArrayIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.10.

Page 176

Syntax DellPhysicalMemoryArrayUse (See Physical Memory Array ECC Type Definitions)Access Read-onlyTable 939. Physical Memory Array Error Checking an

Page 177 - Device Group

Table 943. Physical Memory Array In Use Number SocketsName physicalMemoryArrayInUseNumberSocketsObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11Descrip

Page 178 - Device Tables

Syntax DellObjectRangeAccess Read-onlyTable 948. Physical Memory Array Extended Maximum SizeNOTE: This attribute replaces the physicalMemoryArrayMax

Page 179

Table 19. Systems Management Software Supported ProtocolName systemManagementSoftwareSupportedProtocolObject ID 1.3.6.1.4.1.674.10892.1.100.5Descript

Page 180 - Keyboard Device Table

Syntax DellObjectRangeAccess Read-onlyTable 952. Physical Memory Array Mapped IndexName physicalMemoryArrayMappedIndexObject ID 1.3.6.1.4.1.674.108

Page 181

Syntax DellObjectRangeAccess Read-onlyTable 957. Physical Memory Array Mapped Starting AddressName physicalMemoryArrayMappedStartingAddressObject ID

Page 182 - Processor Device Table

Access Not accessibleTable 961. Physical Memory Configuration Table EntryName physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.

Page 183

Table 965. Physical Memory Configuration State SettingsName physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4Descriptio

Page 184

Table 970. Physical Memory Configuration MOM SettingsName physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9Description D

Page 185

Description Defines the index (one-based) of the physical memory logging.Syntax DellObjectRangeAccess Read-onlyTable 975. Physical Memory Logging Capa

Page 186

Description Defines the Redundant Memory Unit Table entry.Syntax RedundantMemoryUnitTableEntryAccess Not accessibleIndex redundantMemoryUnitChassis

Page 187

Table 984. Redundant Memory Unit Redundancy StatusName redundantMemoryUnitRedundancyStatusObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5Description D

Page 188 - Processor Device Status Table

Syntax PhysicalMemoryCardTableEntryAccess Not accessibleIndex physicalMemoryCardChassisIndex,physicalMemoryCardIndexTable 989. Physical Memory Card

Page 189

Table 993. Physical Memory Card StatusName physicalMemoryCardStatusObject ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5Description Defines the status of th

Page 190 - Cache Device Table

Table 24. Systems Management Software Global Version NameName systemManagementSoftwareGlobalVersionNameObject ID 1.3.6.1.4.1.674.10892.1.100.10Descri

Page 191

Syntax DellObjectRangeAccess Read-onlyMemory Group Variable ValuesThis section includes definitions for server administrator-specific variable value

Page 192 - Table 728. Cache Device Level

Possible Data Values Meaning of Data ValuememoryArrayECCTypeIsOther(1)There is not one of the following:memoryArrayECCTypeIsUnknown(2)The memory arra

Page 193 - Table 731. Cache Device Speed

If set to 0 (zero)There are no redundant memory capabilities.unknownCapabilities(1)Redundant capabilities are unknown.The redundant capabilities are:s

Page 194 - Memory Device Table

If set to 0 (zero)There are no logging settings enabled. unknownCapabilities(1)Logging capabilities are unknown.The logging settings are:enabled(2)Log

Page 195

Syntax BiosSetUpControlTableEntryAccess Not accessibleIndex biosSetUpControlchassisIndexTable 1008. BIOS Setup Control Chassis IndexName biosSetUpCont

Page 196 - Table 746. Memory Device Type

Syntax DellStringAccess Read-onlyTable 1013. BIOS Setup Control Numeric Lock Control CapabilitiesNamebSUCnumLockControlCapabilitiesObject ID 1.3.6.1.4

Page 197 - Table 753. Memory Device Size

Access Read-onlyTable 1018. BIOS Setup Control Processor Serial Number Control SettingsName bSUCprocessorSerialNumberControlSettingsObject ID 1.3.6.

Page 198

Access Read-onlyTable 1023. BIOS Setup Control Speaker Control StatusName bSUCspeakerControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16Desc

Page 199

Syntax DellStatusAccess Read-onlyTable 1028. BIOS Setup Control NIF Wakeup on LAN Control NameName bSUCnIFwakeonLanControlNameObject ID 1.3.6.1.4.1.

Page 200 - Table 765. Memory Device Rank

Syntax DellStringAccess Read-onlyTable 1033. BIOS Setup Control Administrator Password Control Capabilities UniqueName bSUCadministratorPasswordCont

Page 201

supportsSNMPandDMI(3) This system supports SNMP and DMI.supportsCIMOM(4) This system supports CIM.supportsSNMPandCIMOM(5) This system supports SNMP an

Page 202

current administrator password immediately preceding this password change.Syntax DellStringAccess Read-onlyTable 1038. BIOS Setup Control User Passw

Page 203 - Generic Device Table

Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user passw

Page 204

SCSI Control TableTable 1047. SCSI Control TableName sCSIControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.20Description Defines the Small Computer

Page 205 - PCI Device Table

Access Read-onlyTable 1052. SCSI Control SettingsName sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4Description Defines the stat

Page 206

,parallelPortControlIndexTable 1057. Parallel Port Control Chassis IndexName parallelPortControlchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.30

Page 207 - Table 801. PCI Device Speed

Access Read-onlyTable 1062. Parallel Port Control NameName parallelPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6Description Defines

Page 208

,serialPortControlIndexTable 1067. Serial Port Control Chassis IndexName serialPortControlchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1De

Page 209

Table 1072. Serial Port Control NameName serialPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6Description Defines the setup BIOS name o

Page 210 - Network Device Table

Access Read-onlyTable 1077. USB Control CapabilitiesName usbControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3Description Defines the

Page 211

Access Not accessibleTable 1082. IDE Control Table EntryName ideControlTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1Description Defines the

Page 212

For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power supplies for the chassis.The variables in List 2 provide

Page 213

Access Read-onlyTable 1087. IDE Control StatusName ideControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5Description Defines the status for

Page 214 - Table 836. Network Device IRQ

Access Read-onlyTable 1092. Diskette Control IndexName disketteControlIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2Description Defines the ind

Page 215

Table 1097. Network Interface Control TableName networkInterfaceControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.80Description Defines the Network

Page 216

Access Read-onlyTable 1102. Network Interface Control Settings UniqueName networkInterfaceControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.140

Page 217 - SD Card Unit Table

Syntax BiosSettingTableEntryAccess Not accessibleIndex biosSettingChassisIndex,biosSettingIndexTable 1107. BIOS Setting Chassis IndexName biosSettin

Page 218 - Table 856. SD Card Unit Index

Syntax DellBIOSSettingValueTypeAccess Read-onlyTable 1112. BIOS Setting Current ValueName biosSettingCurrentValueObject ID 1.3.6.1.4.1.674.10892.1.

Page 219 - SD Card Device Table

Table 1117. BIOS Setting Group Display NameName biosSettingGroupDisplayNameObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11Description Defines the dis

Page 220

medium(8) Speaker control volume is medium.high(16) Speaker control volume is high.Table 1121. Network Interface (NIF) Wakeup on LAN Capabilities Uniq

Page 221

bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first.bootFromDeviceListCapable(8) Setup BIOS can

Page 222 - Device Group Variable Values

passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.Table 1127. BIOS Password Control Setti

Page 223

Contents1 Introduction... 9What’s New in T

Page 224

• systemStateSDCardUnitStatusList• systemStateSDCardDeviceStatusListSystem State TableThe following object sets up the System State Table:Table 31. Sy

Page 225

lpt1Capable(4) Setup BIOS can support parallel port 1.lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.lpt2Capable(8) Setup BIOS can sup

Page 226

Table 1133. Serial Port Control CapabilitiesVariable Name: DellSerialPortControlCapabilitiesUnique Data Type: IntegerPossible Data Values Meaning of

Page 227

com4(32) Setup BIOS has selected serial port 4.com4Enabled(34) Setup BIOS has enabled serial port 4.comPortsAutoConfig(64) Setup BIOS has selected aut

Page 228

unknown(1) Network interface state is unknown.enabled(2) Network interface is enabled.enabledWithoutPXE(4) Network interface is enabled without PXE.Ta

Page 229

Description Defines the LRA Global Settings Table.Syntax SEQUENCE OF LRAGlobalSettingsTableEntryAccess Not accessibleTable 1141. LRA Global Setting

Page 230

Table 1145. LRA Global Settings Capabilities UniqueName lRAGlobalSettingsCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4Description

Page 231

Table 1149. LRA Action Table EntryName lRAActionTableTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1500.20.1Description Defines the LRA Action Table e

Page 232

• 1554 — log full action definition• 1603 — processor warning action definition• 1604 — processor failure action definition• 1703 — battery warning ac

Page 233

rebootCapable(16) The LRA can reboot the system.powerCycleCapable(32) The LRA is capable of a system power cycle.powerOFFCapable(64) The LRA can shut

Page 234

powerOFF(64) LRA is set to issue a system power off.executeApplication(256) LRA is set to start a user mode application.allLRASettingsUnique(383) LRA

Page 235 - Table 885. Cache Device Level

Table 35. System State Chassis StateName systemStateChassisStateObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.3Description Defines the system state of

Page 236

Access Not accessibleIndexcoochassisIndexTable 1159. COO Chassis IndexNamecoochassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1Description Defi

Page 237

Access Read-onlyTable 1164. COO Acquisition Purchase OrderNamecooAquisitionPurchaseOrderObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6Description Defin

Page 238

Access Read-onlyTable 1169. COO Cost Center Information Vendor NameNamecooCostCenterInformationVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1

Page 239 - Table 893. Memory Device Type

Access Read-onlyTable 1174. COO Extended Warranty Provider NameNamecooExtendedWarrantyProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16Descri

Page 240

Access Read-onlyTable 1179. COO Deployment Duration TypeNamecooDeploymentDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21Description Defines

Page 241

Access Read-onlyTable 1184. COO Outsourcing Provider Fee NameNamecooOutsourcingProviderFeeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26Descriptio

Page 242

Access Read-onlyTable 1189. COO Box Central Processing Unit (CPU) Serial Number NameNamecooBoxCPUSerialNumberNameObject ID 1.3.6.1.4.1.674.10892.1.160

Page 243

Access Read-onlyTable 1194. COO Depreciation Duration TypeNamecooDepreciationDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36Description Def

Page 244

Description Defines the COO Service Contract Table.Syntax SEQUENCE OF CooServiceContractTableEntryAccess Not accessibleTable 1199. COO Service Contrac

Page 245

Table 1203. COO Service Contract Was RenewedNamecooServiceContractWasRenewedObject ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4Description Specifies whether

Page 246 - Slot Group

Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string r

Page 247 - Table 914. System Slot Status

Access Not accessibleIndexcooCostEventLogchassisIndex,cooCostEventLogIndexTable 1208. COO Cost Event Log Chassis IndexNamecooCostEventLogchassisIndexO

Page 248 - Table 918. System Slot Length

Description Defines the duration type of the event for this system.Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type)Access Read-onlyT

Page 249 - System Slot Variable Values

Access Read-onlyTable 1217. COO Warranty IndexNamecooWarrantyIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2Description Defines the index of the wa

Page 250

Access Read-onlyTable 1222. COO Warranty CostNamecooWarrantyCostObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7Description Defines the cost of the warra

Page 251 - Table 926. System Slot Type

Table 1226. COO Lease Information IndexNamecooLeaseInformationIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2Description Defines the index of the l

Page 252

Table 1231. COO Lease Information End Date NameNamecooLeaseInformationEndDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7Description Defines the

Page 253 - Table 928. System Slot Length

,cooScheduleNumberIndexTable 1236. COO Schedule Number Chassis IndexNamecooScheduleNumberchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1Desc

Page 254 - Memory Group

Syntax DellCostofOwnershipStringAccess Read-onlyCOO Options TableTable 1241. COO Options TableName cooOptionsTableObject ID 1.3.6.1.4.1.674.10892.1.16

Page 255 - Physical Memory Array Table

Table 1245. COO Options StateName cooOptionsStateObject ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3Description Defines the option information state for thi

Page 256

IndexcooMaintenancechassisIndex,cooMaintenanceIndexTable 1250. COO Maintenance Chassis IndexNamecooMaintenancechassisIndexObject ID 1.3.6.1.4.1.674.10

Page 257

Table 43. System State Voltage State DetailsName systemStateVoltageStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.11Description Defines the

Page 258

Syntax DellDateNameAccess Read-onlyTable 1255. COO Maintenance Provider NameNamecooMaintenanceProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.80.1.

Page 259

Table 1259. COO Repair Chassis IndexNamecooRepairchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1Description Defines the index (one-based) of

Page 260

COO Support Information TableTable 1264. COO Support Information TableName cooSupportInformationTableObject ID 1.3.6.1.4.1.674.10892.1.1600.100Descrip

Page 261

Description Defines the support information state for this system.Syntax DellStateSettingsAccess Read-onlyTable 1269. COO Support Information Is Outso

Page 262

Table 1273. COO Trouble Ticket TableNamecooTroubleTicketTableObject ID 1.3.6.1.4.1.674.10892.1.1600.110Description Defines the COO Trouble Ticket Tabl

Page 263

Access Read-onlyTable 1278. COO Trouble Ticket Support Information Index ReferenceNamecooTroubleTicketSupportInformationIndexReferenceObject ID 1.3.6.

Page 264 - Physical Memory Logging Table

unknown(1)Duration time type is unknown.hours(2)Duration time type is in hours.days(3)Duration time type is in days.Table 1282. COO Day Month Duration

Page 265 - Redundant Memory Unit Table

Access Not accessibleTable 1285. Remote Access Table EntryNameremoteAccessTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1Description Defines the

Page 266

Access Read-onlyTable 1290. Remote Access State SettingsNameremoteAccessStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5Description Defines

Page 267 - Physical Memory Card Table

Table 1295. Remote Access Local Area Network (LAN) CapabilitiesNameremoteAccessLANCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14Descriptio

Page 268

Table 47. System State Amperage Status CombinedName systemStateAmperageStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.15Description Define

Page 269

Table 1300. Remote Access Personal Computer Memory Card International Association (PCMCIA) Info NameNameremoteAccessPCMCIAInfoNameObject ID 1.3.6.1.4.

Page 270 - Memory Group Variable Values

Table 1305. Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)NameremoteAccessNICCurrentInfoFromDHCPObject ID 1.3.6

Page 271

logResetCapable(2)The remote access hardware can reset its integrated logs.hardResetCapable(4)The remote access hardware can perform a hard reset.soft

Page 272

extPwrSupplyMonitorIfConn ectedCapable(2)The remote access hardware can be set to monitor the external power supply, if connected.extPwrSupplyMonitorA

Page 273 - BIOS Setup Control Group

unknown(1)The remote access hardware LAN settings are unknown.nicEnabled(2)The remote access hardware NIC is enabled.nicDHCPEnabled(4)The remote acces

Page 274

unknownCapabilities(1)The remote access hardware out-of-band SNMP capabilities are unknown.oobSNMPAgentCapable(2)The remote access hardware has an out

Page 275

none(0)The admin user has no state settings.unknown(1)The admin user state settings are unknown.enabled(2)The admin user is enabled.notReady(4)The adm

Page 276

other(1)The remote user admin alpha protocol type is not one of the following:unknown(2)The remote user admin alpha protocol type is unknown.alpha7E0(

Page 277

enabled(2)The SNMP trap destination is enabled.notReady(4)The SNMP trap destination is in the not ready state.Table 1326. Remote SNMP Trap Control Cap

Page 278

dialInDHCPCapable(32)The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature.dialInAuthAnyCapable(64)The dial

Page 279

Access Read-onlyTable 51. System State Cooling Unit State DetailsName systemStateCoolingUnitstateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.1

Page 280

remoteDialUpIsOther(1)The remote dial type is not one of the following:remoteDialUpIsUnknown(2)The remote dial type is unknown.remoteDialUpIsTone(3)Th

Page 281

Data Type:IntegerPossible Data Values Meaning of Data Valuenone(0)The dial-out destination has no state capabilities.unknownCapabilities(1)The dial-ou

Page 282 - SCSI Control Table

systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system.Cluster GroupThe Cluster Grou

Page 283 - Parallel Port Control Table

Access Read-onlyTable 1339. Cluster State CapabilitiesNameclusterStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3Description Defines the

Page 284

Table 1344. Cluster NameNameclusterNameObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8Description Defines the name of the cluster.Syntax DellStringAcces

Page 285 - Serial Port Control Table

Syntax SEQUENCE OF BmcTableEntryAccess Not accessibleTable 1347. BMC Table EntryNamebmcTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1Descriptio

Page 286

Syntax DellStateSettingsAccess Read-onlyTable 1352. BMC StatusNamebmcStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5Description Defines the status

Page 287 - USB Control Table

Table 1357. BMC TypeNamebmcTypeObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10Description Defines the type of the BMC.Syntax DellManagementControllerTy

Page 288 - IDE Control Table

Baseboard Management Controller Serial InterfaceTable 1362. BMC Serial Interface TableNamebmcSerialInterfaceTableObject ID 1.3.6.1.4.1.674.10892.1.190

Page 289 - Table 1084. IDE Control Index

Syntax DellObjectRangeAccess Read-onlyTable 1367. BMC Serial Interface State CapabilitiesNamebmcSerialInterfaceStateCapabilitiesObject ID 1.3.6.1.4.1.

Page 290 - Diskette Control Table

the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represent

Page 291

Table 1372. BMC Serial Interface Connection Mode SettingsNamebmcSerialInterfaceConnectionModeSettingsObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9Desc

Page 292

,bmcLANInterfaceBMCIndex,bmcLANInterfaceIndexTable 1377. BMC LAN Interface Chassis IndexNamebmcLANInterfaceChassisIndexObject ID 1.3.6.1.4.1.674.10892

Page 293 - BIOS Setting Table

Access Read-onlyTable 1382. BMC LAN Interface StatusNamebmcLANInterfaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6Description Defines the stat

Page 294 - Table 1109. BIOS Setting Name

Table 1387. BMC LAN Interface Default Gateway AddressNamebmcLANInterfaceDefaultGatewayAddressObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11Description

Page 295

directPPP(16)BMC serial interface supports Direct PPP mode.directTerminal(32)BMC serial interface supports Direct Terminal mode.Table 1391. BMC Serial

Page 296 - BIOS Group Variable Values

Table 1394. BMC LAN IP Address Source TypeVariable Name:DellBMCLANIPAddressSourceTypeData Type:IntegerPossible Data Values Meaning of Data Value-- uns

Page 297

formFactorTypeIsDualWidthHalfHeight(2)Form Factor Type is DualWidthHalfHeight.formFactorTypeIsSingleWidthFullHeight(3)Form Factor Type is SingleWidthF

Page 298

,fruIndexTable 1399. FRU Chassis IndexName fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1Description Defines the index (one-based) of

Page 299

Table 1404. FRU Manufacturer NameName fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6Description Defines the manufacturer of the F

Page 300

Description Defines the asset tag of the FRU.Syntax DisplayString (SIZE (0..64))Access Read-onlyField Replaceable Unit Group Variable ValuesThis se

Page 301

Table 58. System State Memory Device State DetailsName systemStateMemoryDeviceStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.26Description D

Page 303 - Local Response Agent Group

3Storage Management GroupThe Storage Management Group is composed of the following:• Storage Management Group—information about the software product a

Page 304 - Table 1143. LRA Global State

4: UnknownSyntax IntegerAccess Read-onlyTable 1413. Software ManufacturerName softwareManufacturerObject ID 1.3.6.1.4.1.674.10893.1.20.3Description

Page 305 - LRA Action Table

Table 1417. DescriptionName descriptionObject ID 1.3.6.1.4.1.674.10893.1.20.100.2Description Provides a short description of this management softwar

Page 306

Syntax IntegerAccess Read-onlyTable 1422. Agent Time StampName agentTimeStampObject ID 1.3.6.1.4.1.674.10893.1.20.110.3Description Identifies the

Page 307

Table 1426. Agent HostnameName agentHostnameObject ID 1.3.6.1.4.1.674.10893.1.20.110.7Description This entry is obsolete for Storage Management.Synt

Page 308

Table 1431. Agent Management Software URL NameName agentManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.10893.1.20.110.12Description Identifies t

Page 309 - Cost of Ownership Group

Syntax DellStatusAccess Read-onlyTable 1434. Agent Smart Thermal ShutdownName agentSmartThermalShutdownObject ID 1.3.6.1.4.1.674.10893.1.20.110.15D

Page 310 - Table 1160. COO State

• EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresp

Page 311

Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance.

Page 312

second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings.Syntax Octet StringAccess Read-onlyTable

Page 313

Access Read-onlyTable 1442. Controller SeverityName controllerSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6Description This entry is obsol

Page 314 - Table 1180. COO Training Name

Syntax IntegerAccess Read-onlyTable 1446. Controller Physical Device CountName controllerPhysicalDeviceCountObject ID 1.3.6.1.4.1.674.10893.1.20.13

Page 315

Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only suppo

Page 316

Access Read-onlyTable 1455. Controller C0 Port 0 NameName controllerC0Port0NameObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20Description This entr

Page 317 - COO Service Contract Table

Description This entry is obsolete. Fibre channel is not supported in Storage Management.Syntax DisplayStringAccess Read-onlyTable 1460. Controller

Page 318

Table 1464. Controller C1 TargetName controllerC1TargetObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29Description This entry is obsolete. Fibre chan

Page 319 - COO Cost Event Log Table

Syntax DisplayStringAccess Read-onlyTable 1469. Controller C0 Port 1 World Wide NameName controllerC0Port1WWNObject ID 1.3.6.1.4.1.674.10893.1.20.1

Page 320

Syntax DellStatusAccess Read-onlyTable 1473. Controller Component StatusName controllerComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.

Page 321 - COO Warranty Table

Description Indicates currently installed driver version of the controllerSyntax DisplayStringAccess Read-onlyTable 1477. Controller PCI SlotName c

Page 322

Access Read-onlyTable 1481. Controller SCSI Initiator IDName controllerSCSIInitiatorIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46Description Th

Page 323 - COO Lease Information Table

Syntax DellStatusRedundancyAccess Read-onlyTable 66. System State AC Power Switch Status DetailsName systemStateACPowerSwitchStatusDetailsObject ID

Page 324

Access Read-onlyTable 1486. Controller Check Consistency RateName controllerCheckConsistencyRateObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51Descr

Page 325 - COO Schedule Number Table

Table 1490. Controller Storport Driver VersionName controllerStorportDriverVersionObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55Description Provide

Page 326

Access Read-onlyTable 1494. Controller Spin Down Unconfigured DrivesName controllerSpinDownUnconfiguredDrivesObject ID 1.3.6.1.4.1.674.10893.1.20.13

Page 327 - COO Options Table

Table 1498. Controller CacheCadeName controllerCacheCadeObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64Description Indicates if the controller is Ca

Page 328 - COO Maintenance Table

Description Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time windo

Page 329

Table 1506. Channel EntryName channelEntryObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1Description Defines the channel table entry.Syntax ChannelEntr

Page 330 - COO Repair Table

Table 1510. Channel SeverityName channelSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4Description This entry is obsolete for Storage Managem

Page 331 - Table 1261. COO Repair State

Syntax DellStatusAccess Read-onlyTable 1514. Channel Component StatusName channelComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8Descr

Page 332 - COO Support Information Table

3: Fibre Channel4: Serial Storage Architecture (SSA)6: Universal Serial Bus (USB)7: SATA8: SAS9: PCIeSyntax IntegerAccess Read-onlyEnclosure TableTh

Page 333 - COO Trouble Ticket Table

Description Identifies the enclosure's name as represented in Storage Management.Syntax DisplayStringAccess Read-onlyTable 1522. Enclosure Ven

Page 334

System Resource Group... 87System Re

Page 335

Access Read-onlyTable 70. System State Redundant Memory Unit State DetailsName systemStateRedundantMemoryUnitStateDetailsObject ID 1.3.6.1.4.1.674.1

Page 336 - Remote Access Group

Syntax DisplayStringAccess Read-onlyTable 1526. Enclosure Processor VersionName enclosureProcessorVersionObject ID 1.3.6.1.4.1.674.10893.1.20.130.3

Page 337

Access Read-onlyTable 1531. Enclosure Product IDName enclosureProductIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12Description Identifies the en

Page 338

2: Dell PowerVault 200S (PowerVault 201S)3: Dell PowerVault 210S (PowerVault 211S)4: Dell PowerVault 220S (PowerVault 221S)5: Dell PowerVault 660F6: D

Page 339

Table 1539. Enclosure AlarmName enclosureAlarmObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20Description Identifies the current status of the enclos

Page 340

Access Read-onlyTable 1543. Enclosure Component StatusName enclosureComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24Description The s

Page 341 - Remote Access Variable Values

Table 1547. Enclosure Part NumberName enclosurePartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28Description The part number of the enclosure

Page 342

NOTE: A value of 9999 indicates that the feature is not available.Syntax IntegerAccess Read-onlyTable 1552. Enclosure Empty Slot CountName enclosure

Page 343

Access Read-onlyTable 1556. Array Disk NameName arrayDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2Description Identifies the name of the a

Page 344

34: Predictive Failure35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.39: Foreign40: Clear41: Unsupporte

Page 345

Syntax DisplayStringAccess Read-onlyTable 1563. Array Disk Enclosure IDName arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9Desc

Page 346

Table 74. System State Power Unit Status CombinedName systemStatePowerUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.42Description Def

Page 347

Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte.Syntax Integ

Page 348

Table 1572. Array Disk Used Space in BytesName arrayDiskUsedSpaceInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18Description Identifies the si

Page 349

Syntax IntegerAccess Read-onlyTable 1576. Array Disk Spare StateName arrayDiskSpareStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22Description

Page 350

4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1579. Array Disk Device NameName arrayDiskDeviceNameObject ID 1.

Page 351 - Cluster Group

Description Indicates the speed at which the drive is actually running in MPS (megabytes per second).Syntax IntegerAccess Read-onlyTable 1584. Arra

Page 352

Table 1588. Array Disk Manufacture YearName arrayDiskManufactureYearObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34Description Indicates the four di

Page 353 - Table 1342. Cluster Type

Syntax Octet StringAccess Read-onlyTable 1593. Array Disk Alta Revision IdName arrayDiskAltaRevisionIdObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.

Page 354 - Cluster Group Variable Values

Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined/NotApplicableSyntax Int

Page 355 - Table 1349. BMC Index

Syntax INTEGERAccess Read-onlyTable 1602. Array Disk Read OnlyName arrayDiskReadOnlyObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48Description Pro

Page 356 - Table 1356. BMC GUID

Access Read-onlyTable 1606. Array Disk Max Link WidthName arrayDiskMaxLinkWidthObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.52Description Provides

Page 357 - Table 1360. BMC IPv6 URL Name

Table 78. System State AC Power Switch Status CombinedName systemStateACPowerSwitchStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.46Descrip

Page 358

Description Defines the array disk enclosure connection table entry.Syntax Syntax ArrayDiskEnclosureConnectionEntryAccess Not accessibleIndexIndex a

Page 359

Table 1614. Array Disk Enclosure Connection Enclosure NumberName arrayDiskEnclosureConnectionEnclosureNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.

Page 360 - Table 1375. BMC LAN Interface

NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management.The foll

Page 361

Fan TableThis table describes available properties for each fan on the managed system.The following object sets up the Fan Table.Table 1626. Fan Table

Page 362

Description Identifies the fan's (re)seller's name.Syntax DisplayStringAccess Read-onlyTable 1631. Fan StateName fanStateObject ID 1.3.6.

Page 363

Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.Syntax DisplayStringAccess Read-onlyTabl

Page 364

Table 1639. Fan1 Part NumberName fan1PartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12Description Identifies the part number of the fan in the

Page 365

4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1643. Fan Nexus IDNamefanNexusIDObject ID 1.3.6.1.4.1.674.10893.1

Page 366 - Field Replaceable Unit Group

Access Not accessibleIndexfanConnectionNumberTable 1647. Fan Connection NumberNamefanConnectionNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1Des

Page 367 - Table 1403. FRU Device Name

Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs.Syntax IntegerAccess Read-onlyPower Supp

Page 368

Table 82. System State Processor Device Status CombinedName systemStateProcessorDeviceStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.50Desc

Page 369

Description Defines the capabilities of the power supply.Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique)Acces

Page 370

Syntax DellStringAccess Read-onlyTable 1662. Power Supply Input VoltageName powerSupplyInputVoltageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.9Desc

Page 371 - Storage Management Group

Access Read-onlyTable 1667. Power Supply Rated Input WattageName powerSupplyRatedInputWattageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.14Descriptio

Page 372 - Table 1416. Display Name

Table 1671. Power Supply Connection Power Supply NameName powerSupplyConnectionPowerSupplyNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2Descript

Page 373 - Global Data Group

NOTE: Available above 1.04 firmware version.Syntax DisplayStringAccess Read-onlyTemperature Probe TableTable 1676. Temperature Probe TableName tempe

Page 374 - Table 1424. Agent Modifiers

Table 1680. Temperature Probe State CapabilitiesName temperatureProbeStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.3Description Define

Page 375 - Table 1430. Agent MIB Version

Access Read-onlyTable 1685. Temperature Probe Location NameName temperatureProbeLocationNameObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.8Description

Page 376

Table 1690. Temperature Probe Lower Critical ThresholdName temperatureProbeLowerCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.13Descrip

Page 377 - Physical Devices Group

Table 1694. Temperature Probe Connection TableName temperatureConnectionTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.12Description Defines the temp

Page 378 - Controller Table

Syntax IntegerAccess Read-onlyTable 1699. Temperature Probe Connection Enclosure NameName temperatureConnectionEnclosureNameObject ID 1.3.6.1.4.1.6

Page 379 - Table 1441. Controller State

Table 86. System State SD Card Unit Status CombinedName systemStateSDCardUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.54Description

Page 380

Index enclosureManagementModuleNumberTable 1703. Enclosure Management Module NumberName enclosureManagementModuleNumberObject ID 1.3.6.1.4.1.674.1089

Page 381

Access Read-onlyTable 1707. Enclosure Management Module SeverityName enclosureManagementModuleSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.

Page 382

Table 1711. Enclosure Management Module Maximum SpeedName enclosureManagementModuleMaxSpeedObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9Description

Page 383

Table 1714. Enclosure Management Module Nexus IDName enclosureManagementModuleNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12Description Dur

Page 384

Table 1718. Enclosure Management Module Connection NumberName enclosureManagementModuleConnectionNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.

Page 385

Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs.Syntax IntegerAccess

Page 386

Description Defines the state capabilities of the battery.Syntax DellStateCapabilitiesAccess Read-onlyTable 1728. Battery State SettingsName batter

Page 387

Table 1732. Battery Connection TableName batteryConnectionTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.16Description Defines the battery connection

Page 388

Access Read-onlyTable 1737. Battery Connection Controller NameName batteryConnectionControllerNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4Des

Page 389

Access Not accessibleTable 1741. Tape Drive NumberNametapeDriveNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1Description Instance number of th

Page 390

chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems managemen

Page 391

Access Read-onlyTable 1746. Tape Drive Bus TypeName tapeDriveBusTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6Description The bus type of the t

Page 392

Virtual Disk TableThis table describes available properties for each virtual disk on the managed system.The following object sets up the Virtual Disk

Page 393

Table 1753. Virtual Device Disk NameName virtualDiskDeviceNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3Description Identifies the device name u

Page 394 - Channel Table

Access Read-onlyTable 1756. Virtual Disk Length in MegabytesName virtualDiskLengthInMBObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6Description Ide

Page 395 - Table 1509. Channel State

Description Indicates whether the controller's write cache are used when writing to a virtual disk.Possible values:1: Enabled - Adaptec Write Ca

Page 396 - Table 1512. Channel SCSI ID

Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAI

Page 397 - Table 1517. Channel Bus Type

Table 1768. Virtual Disk LUN IDName virtualDiskLunIDObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18Description This entry is obsolete. This property

Page 398 - Enclosure Table

Table 1771. Virtual Disk Nexus IDName virtualDiskNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21Description Durable unique ID for this virtua

Page 399 - Table 1525. Enclosure ID

Table 1775. Virtual Disk is CacheCadeName virtualDiskIsCacheCadeObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25Description Indicates if this virtual

Page 400

Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum

Page 401 - Table 1535. Enclosure Type

Table 93. Chassis State CapabilitiesName chassisStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.2Description Defines the capabilities of

Page 402

Access Read-onlyTable 1784. Virtual Disk Partition SizeNamevirtualDiskPartitionSizeObject ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4Description Size of

Page 403 - Table 1541. Enclosure SCSI ID

Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.Syntax Flu

Page 404

Description Indicates the Entitlement Identifier for the license of the fluid cache subsystem.Syntax OCTET STRINGAccess Read-onlyTable 1794. Fluid C

Page 405

Access Read-onlyTable 1799. Fluid Cache License Product IDNamefluidCacheLicenseProductIdObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.11Description In

Page 406 - Array Disk Table

Table 1804. Fluid Cache NexusNamefluidCacheNexusObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.16Description Indicates the unique ID of the fluid cache

Page 407 - Table 1558. Array Disk State

Valid values are 2 - Active, otherwise InactiveSyntax INTEGERAccess Read-onlyTable 1810. Fluid Cache Disk Backend Device TypeNamefluidCacheDiskBacke

Page 408

Table 1814. Fluid Cache Disk Configured ModeNamefluidCacheDiskConfiguredModeObject ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.8DescriptionConfigured Mode o

Page 409

Table 1818. Fluid Cache Pool EntryName fluidCachePoolEntryObject ID 1.3.6.1.4.1.674.10893.1.20.140.6.1Syntax FluidCachePoolEntryAccess Not-Accessib

Page 410 - Table 1570. Array Disk LUN ID

Syntax INTEGERAccess Read-onlyTable 1824. Fluid Cache Pool High Availability StateNamefluidCachePoolHighAvailabilityStateObject ID 1.3.6.1.4.1.674.1

Page 411

Description Defines the array disk logical connection table.Syntax SEQUENCE OF arrayDiskLogicalConnectionEntryAccess Not accessibleTable 1828. Array

Page 412

Table 98. Chassis NameName chassisNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.7Description Defines the user-assigned chassis name of the chassis.

Page 413

Table 1832. Array Disk Logical Connection Virtual Disk NameName arrayDiskLogicalConnectionVirtualDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.3.1

Page 414

Description Storage Management event message number.Syntax IntegerAccess Read-onlyTable 1837. Description EventName descriptionEventObject ID 1.3.

Page 415

Description Durable, unique ID of the object causing the alert.Syntax DisplayStringAccess Read-onlyTable 1842. Current Status EventName currentStat

Page 416

4Change Management GroupThe Change Management Group lets you monitor information about the Dell devices and software that are present on a particular

Page 417

Device Group TableThe following object sets up the Device Group Table.Table 1847. Device TableNamedeviceTableObject ID 1.3.6.1.4.1.674.10899.1.5Descri

Page 418

Table 1852. Device Vendor IDNamedeviceVendorIDObject ID 1.3.6.1.4.1.674.10899.1.5.1.4Description Defines the ID for the vendor supplying the device.Sy

Page 419

Table 1856. Application TableNameapplicationTableObject ID 1.3.6.1.4.1.674.10899.1.6Description Defines a table of application information for the sys

Page 420

Description Identifies the version of the application.Syntax DisplayStringAccess Read-onlyTable 1862. Application Display StringNameaplicationDisplayS

Page 422

5Chassis Management Controller GroupDell Remote Access Controller Out-of-Band GroupThe Dell Remote Access Controller Out-of-Band MIB contains informat

Page 423 - Fan Table

Description Defines the asset tag name for this chassis.Syntax DellUnsigned8BitRangeAccess Read-onlyTable 104. Chassis ID ExtensionName chassisIDEx

Page 424 - Table 1633. Fan Probe Unit

Access Read-onlyTable 1868. DRsProductVersionNamedrsProductVersionObject ID 1.3.6.1.4.1.674.10892.2.1.1.5Description Defines the product version of a

Page 425

Table 1873. DRsProductChassisNameNamedrsProductChassisNameObject ID 1.3.6.1.4.1.674.10892.2.1.1.10Description Defines the name of the chassis.Syntax D

Page 426 - Table 1640. Fan 2 Part Number

Description Defines the data center locator of the chassis.Syntax DellStringAccess Read-onlyTable 1879. DRsProductChassisAisleNamedrsProductChassisAis

Page 427 - Fan Connection Table

Table 1884. DRsProductChassisSystemIDNamedrsProductChassisSystemIDObject ID 1.3.6.1.4.1.674.10892.2.1.1.21Description Defines the system ID of the cha

Page 428

Table 1889. DRsGlobalCurrStatusNamedrsGlobalCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.1Description Defines the overall chassis status being moni

Page 429

Table 1894. DRsFanCurrStatusNamedrsFanCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.6Description Defines the fan subsystem health status being monit

Page 430 - Table 1660. Power Supply Type

Table 1899. DRsCMAmbientTemperatureNamedrsCMCAmbientTemperatureObject ID 1.3.6.1.4.1.674.10892.2.3.1.11Description Defines the ambient temperature rea

Page 431

Table 1904. DRsRedPrevStatusNamedrsRedPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.4Description Defines the previous redundancy status recorded by

Page 432 - Power Supply Connection Table

Table 1909. DRsCMCPrevStatusNamedrsCMCPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.9Description Defines the CMC health status being monitored by th

Page 433

Description Defines the timestamp of the most recent power health status change.Syntax TimeTicksAccess Read-onlyTable 1915. DRsFanChangeTimeNamedrsFan

Page 434

Table 109. Chassis System Location NameName chassisSystemLocationNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.18Description Defines the user-assig

Page 435

Description Defines the CMC power table.Syntax SEQUENCE OF DrsCMCPowerTableEntryAccess Not-accessibleTable 1920. DRsCMC Power Table EntryNamedrsCMCPow

Page 436

Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently t

Page 437

Description Defines the timestamp of the most recent chassis power accumulator reset.Syntax DellTimestampAccess Read-onlyTable 1930. DRsWattsPeakUsage

Page 438

Syntax DellTimestampAccess Read-onlyTable 1935. DRsWattsReadingNamedrsWattsReadingObject ID 1.3.6.1.4.1.674.10892.2.4.1.1.13Description Defines the in

Page 439

Access Read-onlyTable 1940. DRsPSUMonitoringCapableNamedrsPSUMonitoringCapableObject ID 1.3.6.1.4.1.674.10892.2.4.2.1.4Description Defines the monitor

Page 440

Syntax SEQUENCE OF DrsCMCServerTableEntryAccess Not-AccessibleTable 1945. DRsCMCServerTableEntryNamedrsCMCServerTableEntryObject ID 1.3.6.1.4.1.674.10

Page 441

Table 1949. DRsServerSlotNameNamedrsServerSlotNameObject ID 1.3.6.1.4.1.674.10892.2.5.1.1.4Description Defines the slot name of the CMC server.Syntax

Page 442

Table 1954. DrsCASSChangeTimeNamedrsCASSChangeTimeObject ID 1.3.6.1.4.1.674.10892.2.20.10.4Description Defines the time stamp of the most recent chang

Page 443

Syntax DellStringAccess Read-onlyTable 1959. DrsCA2AlertStatusNamedrsCA2AlertStatusObject ID 1.3.6.1.4.1.674.10892.2.21.10.4Description Defines the st

Page 444

Syntax Octet StringAccess Read-onlyTable 1964. DRsAlertCurrentStatusNamedrsAlertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.2.5000.10.4Description Cu

Page 445

Field Replaceable Unit Group... 366Field Replac

Page 446 - Battery Connection Table

Table 114. Chassis Fan Control Settings UniqueName chassisFanControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.23Description Defines t

Page 448 - Tape Drive Table

6SNMP TrapsSNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management

Page 449 - Table 1743. Tape Drive Vendor

Syntax DisplayStringTable 1968. Table Index OIDVariable Name alertTableIndexOIDObject ID 1.3.6.1.4.1.674.10892.1.5000.10.2Description Specifies the

Page 450 - Logical Devices Group

Table 1973. Message IDVariable Name alertMsgIDObject ID 1.3.6.1.4.1.674.10892.4.5000.10.7Description Specifies the enhanced message ID for the objec

Page 451 - Virtual Disk Table

Description Line Item ExplanationMemory device: DIMM_1A Serial number: 11111111Memory device: DIMM_1B Serial number: 22222222<Additional power supp

Page 452

Description Line Item ExplanationMemory device bank location: <Bank name in chassis>Specifies the name of the memory bank in the system that gen

Page 453

Understanding Trap SeverityTraps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components

Page 454

TrapID Name Description Severity Category Cause Supported by RAC Platformexceeded a threshold1015 alertDrscSELWarning The RAC has detected a new event

Page 455

drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section.T

Page 456

Table 1981. Battery TrapsTrapID Description Category SubCategory Severityalert2BatteryNormal2227 Battery state has returned to normal; or battery pres

Page 457

Table 119. Chassis Identify Flash Control CapabilitiesName chassisIdentifyFlashControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.28Descri

Page 458 - Virtual Disk Partition

Table 1985. Hardware Configuration TrapsTrapID Description Category SubCategory Severityalert2HardwareConfigurationInformation2331 Hardware configurat

Page 459

TrapID Description Category SubCategory Severityalert2PowerSupplyFailure2185 Power supply has detected a failure.Error Events Power Supply CriticalTab

Page 460 - Fluid Cache Table

TrapID Description Category SubCategory Severity2377 System Event Log failure or critical event.Error Events System Event LogCriticalTable 1993. Softw

Page 461 - Table 1790. Fluid Cache Name

Table 1996. Storage Battery TrapsTrapID Description Category Subcategory Severityalert2StorageBatteryInformation4275 Storage battery information. Erro

Page 462

TrapID Description Category Subcategory Severityalert2StorageFanFailure4201 Storage fan failure. Error Events Fan CriticalTable 2000. Storage Physical

Page 463

TrapID Description Category Subcategory Severitystatus change associated with this trap.alert2StorageManagementFailure4177 Storage Management has dete

Page 464 - Fluid Cache Disk

Table 2005. Audit CMC TrapsTrapID Description Category SubCategory Severityalert2CMCAuditInformation8691 Chassis Management Controller audit informati

Page 465

Table 2008. Configuration IO Virtualization TrapsTrapID Description Category SubCategory Severityalert2IOVConfigurationInformation10747 IO virtualizat

Page 466 - Fluid Cache Pool Table

TrapID Description Severity65801 Over-Temperature Problem (Upper Critical - going high)Critical65929 Over-Temperature Problem ClearedInformation131328

Page 467

TrapID Description Severity2715393 Battery Failure Critical2715521 Battery Failure Cleared Information487169 CPU Thermal Trip (Over Temperature Shutdo

Page 468

Table 124. Chassis Watchdog Control Capabilities UniqueName chassiswatchDogControlCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.33Desc

Page 469

TrapID Description Severity552707 Power Supply AC Lost Critical552835 Power Supply AC Restored Information789249 Memory Redundancy has been LostCritic

Page 470 - Table 1836. Message ID Event

7Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the health of storage resources such as con

Page 471 - Table 1840. Object OID Event

Table 2010. Storage Management Alert SeverityAlert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for

Page 472

NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems.Trap VariablesThe Storage Management SNMP traps use a se

Page 473 - Change Management Group

Table 2015. Object OID EventNameobjectOIDEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.5Description MIB OID of the object causing the alert.Syntax Dis

Page 474 - Device Group Table

Access Read-onlyTable 2020. Enhanced System FQDN EventNamesystemFQDNEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.10Description Hostname of object cau

Page 475 - Application Group

storage management messages, see the Dell OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at dell.com/s

Page 476

8iDRAC7 MIBThe Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated

Page 477 - Operating System Group

SNMP Operations Supported SNMP versionGET, GETNEXT, GETBULK SNMP v1, v2c and v3TRAP SNMP v1 and SNMP v2cNOTE: iDRAC7 does not support the SNMP SET op

Page 478

Description This attribute defines the product name of a remote access card.Syntax StringTypeAccess Read-onlyTable 2024. RAC NameNameracShortNameObjec

Page 479 - Product Information

Table 129. Chassis Power Button Control Capabilities UniqueName chassisPowerButtonControlCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1

Page 480 - Table 1870. DRsProductURL

Access Read-onlyTable 2029. RAC TypeNameracTypeObject ID 1.3.6.1.4.1.674.10892.5.1.1.7.0Description This attribute defines the type of a remote access

Page 481

Table 2033. System Service TagNamesystemServiceTagObject ID 1.3.6.1.4.1.674.10892.5.1.3.2.0Description This attribute defines the service tag of the s

Page 482

Description This attribute defines the form factor of the system.Syntax SystemFormFactorEnumAccess Read-onlyTable 2039. System Data Center NameNamesys

Page 483 - Chassis Status

Table 2044. System System IDNamesystemSystemIDObject ID 1.3.6.1.4.1.674.10892.5.1.3.13.0Description This attribute defines the system ID of the system

Page 484 - Table 1892. DRsRedCurrStatus

Status GroupThe Status Group objects provide status information about the system and storage.Table 2049. Global System StatusNameglobalSystemStatusObj

Page 485 - Table 1897. DRsCMCCurrStatus

Storage Details GroupThe Storage Details Group contains tables that provide detailed information about the external storage subsystem of the system in

Page 486 - Table 1903. DRsKVMPrevStatus

Access Read-onlyTable 2054. Alert MessageVariable NamealertMessageObject ID 1.3.6.1.4.1.674.10892.5.3.1.2.0Description Message describing the alert.Sy

Page 487 - Table 1908. DRsTempPrevStatus

Table 2060. Alert Message ArgumentsVariable NamealertMessageArgumentsObject ID 1.3.6.1.4.1.674.10892.5.3.1.8.0Description Concatenated set of strings

Page 488

Table 2064. Battery TrapsTrapID Description Category SubCategory SeverityBattery Normal2227 Battery state has returned to normal; or battery presence

Page 489 - Chassis Power

TrapID Description Category SubCategory Severity2153 Fan failure. System Health Fan Event CriticalTable 2068. Fiber Channel TrapsTrapID Description Ca

Page 490 - CMC Power Information

Table 134. Chassis Reseller System IDName chassisResellerSystemIDObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.43Description Defines the chassis resell

Page 491 - Table 1928. DRsKWhCumulative

Table 2071. NIC TrapsTrapID Description Category SubCategory SeverityNetwork Information 2091 Network information. System Health NIC Config Informatio

Page 492 - Table 1934. DRsWattsResetTime

TrapID Description Category SubCategory SeverityPhysical Disk Warning 2298 Physical disk warning. System Health Physical Disk MinorPhysical Disk Failu

Page 493 - CMC PSU Information

TrapID Description Category SubCategory Severity2273 The system halted because system power exceeds capacity; or the system performance degraded becau

Page 494 - Chassis Servers

Table 2082. Integrated Dual SD Module Redundancy TrapsTrapID Description Category SubCategory SeverityIntegrated Dual SD Module Redundancy Information

Page 495 - CMC Server Information

TrapID Description Category SubCategory Severity2162 Temperature sensor has detected a warning value.System Health Temperature MinorTemperature Probe

Page 496 - Chassis Alert

Table 2089. Voltage Probe TrapsTrapID Description Category SubCategory SeverityVoltage Probe Normal2171 Voltage sensor reading is within range.System

Page 497 - Chassis Alert 2

Table 2092. Enclosure TrapsTrapID Description Category SubCategory SeverityStorage Enclosure Information4339 Enclosure information. Storage Storage En

Page 498 - Legacy Alerting

TrapID Description Category SubCategory Severity4233 Power supply failure. Storage Power Supply CriticalTable 2096. Storage Management Status TrapsTra

Page 499 - Table 1966. DRsAlertData

Updates Trap GroupThe Updates Trap Group contains traps that fall under the Updates event category of iDRAC7. Updates traps are traps generated in res

Page 500

Configuration Trap GroupThe Configuration Trap Group contains traps that fall under the Configuration event category of the iDRAC7. Configuration trap

Page 501

Table 139. Chassis System Revision NameName chassisSystemRevisionNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.48Description Defines the revision n

Page 503 - Table 1977. Trap Description

9Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts across the information technology

Page 504

unknownCapabilities(1)The object’s capabilities are unknown.enableCapable(2)The object can be disabled (offline, a binary 0 value) or enabled (online,

Page 505

ok(3)The object’s status is OK.nonCritical(4)The object’s status is warning, noncritical.critical(5)The object’s status is critical (failure).nonRecov

Page 506 - RAC Traps

the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4.Full DatesVariable Name: De

Page 507 - PowerEdge M1000e CMC Traps

10SNMP Sample OutputThis appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the

Page 508 - PowerEdge VRTX CMC Traps

1.3.6.1.4.1.674.10892.1.200.10.1.23.1 ='\02\02\02\02\02\02'1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 31.3.6.1.4.1.674.10892.1.200.10.1.25.1 =&

Page 509 - Table 1984. Fan Traps

1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 81.3.6.1.4.1.674.10892.1.

Page 510 - Table 1987. Link Status Traps

,uUIDchassisIndexTable 144. UUID Chassis IndexName uUIDchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.1Description Defines the index (one-ba

Page 511 - Table 1990. Redundancy Traps

Table 148. POST Log TableName postLogTableObject ID 1.3.6.1.4.1.674.10892.1.300.30Description Defines the POST Log Table.Syntax SEQUENCE OF PostLog

Page 512 - Storage Trap Group

Access Read-onlyTable 153. POST Log State Settings UniqueName postLogStateSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.4Description Def

Page 513 - Table 1999. Storage Fan Traps

Syntax EventLogTableEntryAccess Not accessibleIndex eventLogchassisIndex,eventLogRecordIndexTable 158. Event Log Chassis IndexName eventLogchassisIn

Page 514

Inventory Collector Product Information... 4775 Chassis Managemen

Page 515 - Audit Traps

Table 162. Event Log RecordName eventLogRecordObject ID 1.3.6.1.4.1.674.10892.1.300.40.1.5Description Defines the data for the specified chassis and

Page 516 - Configuration Traps

Description Defines the System BIOS Table.Syntax SEQUENCE OF SystemBIOSTableEntryAccess Not accessibleTable 167. System BIOS Table EntryName system

Page 517 - BMC Traps

Table 171. System BIOS State SettingsName systemBIOSStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.4Description Defines the state of the sy

Page 518

Table 176. System BIOS Starting AddressNamesystemBIOSStartingAddressObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.9Description Defines the starting addre

Page 519

Bit 3 BIOS Characteristics Not SupportedBit 4 ISA is supportedBit 5 MCA is supportedBit 6 EISA is supportedBit 7 PCI is supportedBit 8 PC Card (PCMCIA

Page 520

Bit 30 Int 10h, CGA/Mono Video Services are supportedBit 31 NEC PC-98Bit 32 -47ReservedBit 48 Built-in NIC supports Magic PacketBit 49 System supports

Page 521 - Alert Severity Levels

Bit Position Meaning if SetBit 0 BIOS Boot Specification supportedBit 1 Function key-initiated Network Service boot supportedBit 2 Targeted Content Di

Page 522 - SNMP Trap Definitions

Table 185. Firmware IndexNamefirmwareIndexObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.2Description Defines the index (one-based) of the firmware in thi

Page 523 - Trap Variables

Table 190. Firmware TypeNamefirmwareTypeObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.7Description Defines the type of the firmware.Syntax DellFirmwareTy

Page 524 - Table 2015. Object OID Event

Table 195. Intrusion TableNameintrusionTableObject ID 1.3.6.1.4.1.674.10892.1.300.70Description Defines the Intrusion Table.Syntax SEQUENCE OF Intrusi

Page 525 - Viewing SNMP Traps

iDRAC7 Supported SNMP Versions... 527iDRAC7 SNMP Data S

Page 526

Table 200. Intrusion State SettingsNameintrusionStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.70.1.4Description Defines the settings of the intru

Page 527 - Supported Systems

Table 205. Baseboard TableNamebaseBoardTableObject ID 1.3.6.1.4.1.674.10892.1.300.80Description Defines the Baseboard Table.Syntax SEQUENCE OF BaseBoa

Page 528 - RAC Information Group

Table 210. Baseboard State SettingsNamebaseBoardStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.4Description Defines the state settings of the

Page 529 - Table 2028. RAC URL

Description Defines the location name of the baseboard.Syntax DellStringAccess Read-onlyTable 216. Baseboard Manufacturer NameNamebaseBoardManufacture

Page 530 - System Information Group

Table 221. Baseboard Asset Tag NameNamebaseBoardAssetTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.15Description Defines the baseboard asset tag n

Page 531

lapTop(9)The chassis type is a laptop.noteBook(10)The chassis type is a notebook.handHeld(11)The chassis type is a handheld.dockingStation(12)The chas

Page 532 - Table 2043. System Model Name

lowSpeedCapable(2)The fan can be set to low speed.highSpeedCapable(4)The fan can be set to high speed.lowOrhighSpeedCapable(6)The fan can be set to lo

Page 533 - Table 2046. System Room Name

resetCapable(8)The hard-drive fault LED can be reset.Table 230. Hard-Drive Fault LED Control SettingsVariable Name : DellHDFaultLEDControlSettingsData

Page 534 - Systems Details Group

unknown(1)The chassis identification control’s state is unknown..enabled(2)The chassis identification control’s state is disabled (offline, a binary 0

Page 535 - Storage Details Group

manualPowerOffWithoutOSSh utdownCapable(128)The operator can power off without operating system shutdown.manualPowerCycleWithOSShu tdownCapable(256)Th

Page 537 - System Trap Group

automaticPowerOffCapable(16)Watchdog controls can be set to automatically power off host.automaticAllExceptNotificationCap able(27)Watchdog controls c

Page 538 - Table 2067. Fan Traps

enableCapable(2)The power button can be enabled (online) or disabled (offline).Table 239. Power Button Control SettingsVariable Name : DellPowerButton

Page 539

Table 243. Baseboard TypeVariable Name : DellBaseBoardTypeData Type: IntegerPossible Data Values Meaning of Data Valueunknown(1)The baseboard type is

Page 540 - Table 2073. PCI Device Traps

Table 245. Firmware TypeVariable Name : DellFirmwareTypeData Type: IntegerPossible Data Values Meaning of Data Valueother(1)The firmware type is other

Page 541 - Table 2078. Power Usage Traps

Data Type: IntegerPossible Data Values Meaning of Data ValueNOTE: These values are bit fields, so combination values are possible.no features(0)This b

Page 542 - Table 2079. Redundancy Traps

Table 249. Operating System Memory Chassis IndexName operatingSystemMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.1Description Define

Page 543

Table 254. Operating System Memory Available Physical SizeName operatingSystemMemoryAvailablePhysicalSizeObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.6

Page 544

Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.11Description This attribute defines the total physical memory for the operating system memory in KBytes.

Page 545

Table 262. System Resource Map Chassis IndexName systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1Description Defines the i

Page 546 - Table 2093. Fan Traps

Description Defines the type of this system map.Syntax DellSystemResourceMapType (System Resource Map Type)Access Read-onlySystem Resource Owner Ta

Page 547 - Table 2098. Virtual Disk Trap

1IntroductionThis reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is

Page 548 - Audit Trap Group

Table 272. System Resource Owner State CapabilitiesName systemResourceOwnerStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.20.1.3Description

Page 549 - Configuration Trap Group

Description Defines the description name of the system resource owner.Syntax DellStringAccess Read-onlyTable 278. System Resource Owner Interface I

Page 550

Table 282. System Resource I/O Port IndexName systemResourceIOPortIndexObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.2Description Defines the index (on

Page 551 - Capabilities Unique

Table 287. System Resource I/O Port Share DispositionName systemResourceIOPortShareDispositionObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.7Description

Page 552 - Dell Status Data Types

,systemResourceMemoryIndexTable 292. System Resource Memory Chassis IndexName systemResourceMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.500.4

Page 553 - Dell Date

Name systemResourceMemoryOwnerIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.500.40.1.6Description Defines the index to the associated system resou

Page 554 - Full Dates

System Resource Interrupt TableTable 301. System Resource Interrupt TableName systemResourceInterruptTableObject ID 1.3.6.1.4.1.674.10892.1.500.50Des

Page 555 - SNMP Sample Output

Access Read-onlyTable 306. System Resource Interrupt State SettingsName systemResourceInterruptStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.500.50

Page 556

Table 311. System Resource Interrupt TypeName systemResourceInterruptTypeObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.9Description Defines the interru

Page 557

Table 316. System Resource DMA IndexName systemResourceDMAIndexObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.2Description Defines the index of system r

Commentaires sur ces manuels

Pas de commentaire