Dell OpenManage Server Administrator Version 5.4 Guide de l'utilisateur Page 638

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 732
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 637
638 Traps
Temperature Probe Traps
Temperature probes help protect critical components by alerting the systems
management console when temperatures become too high inside a chassis.
The temperature probe traps use additional variables: sensor location, chassis
location, previous state, and temperature sensor value reported in degrees
Celsius.
Table 25-3. Temperature Probe Traps
Trap ID Description Severity Cause
Temperature Probe Normal
1052 Temperature sensor returned
to a normal value
Sensor location:
<Location in chassis>
Chassis location:
<Name of chassis>
Previous state was: <State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
returned to a valid
range after crossing a
failure threshold.
The sensor location,
chassis location,
previous state, and
temperature sensor
value are provided.