Dell OpenManage Server Administrator Version 7.2 Guide de l'utilisateur Page 142

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 573
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 141
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Memory power and performance management type is
Maximum Performance.
mhz1333(2)
Memory power and performance is 1333 MHz. .
mhz1067(4)
Memory power and performance is 1067 MHz.
mhz800(8)
Memory power and performance is 800 MHz.
minPower(16)
Memory power and performance management type is
Minimum Power.
Table 428. Fan Power Performance Management Type
Variable Name: DellFanPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Fan power and performance management type is
Maximum Performance.
minPower(2)
Fan power and performance management type is
Minimum Power.
142
Vue de la page 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 572 573

Commentaires sur ces manuels

Pas de commentaire