Dell Computer Drive CMC 3.2 Manuel d'utilisateur Page 268

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 292
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 267
268 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgIpmiSerialConnectionMode (Read/Write)
cfgIpmiSerialChanPrivLimit (Read/Write)
cfgIpmiSerialFlowControl (Read/Write)
Description When the iDRAC6 cfgSerialConsoleEnable property is set to 0
(disabled), the iDRAC6 serial port becomes the IPMI serial port. This
property determines the IPMI defined mode of the serial port.
In Basic mode, the port uses binary data with the intent of
communicating with an application program on the serial client. In
Terminal mode, the port assumes that a dumb ASCII terminal is
connected and allows very simple commands to be entered.
Legal Values 0 (Terminal)
1 (Basic)
Default 1
Description Specifies the maximum privilege level allowed on the IPMI serial
channel.
Legal Values 2 (User)
3 (Operator)
4 (Administrator)
Default 4
Description Specifies the flow control setting for the IPMI serial port.
Legal Values 0 (None)
1 (CTS/RTS)
Default 1