Dell PowerEdge M IO Aggregator Manuel d'utilisateur Page 79

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 314
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 78
Field Description
ENode MAC MAC address of the ENode.
ENode Interface Slot/ port number of the interface connected to the ENode.
FCF MAC MAC address of the FCF.
VLAN VLAN ID number used by the session.
FC-ID Fibre Channel session ID assigned by the FCF.
show fip-snooping fcf Command Example
Dell# show fip-snooping fcf
FCF MAC FCF Interface VLAN FC-MAP FKA_ADV_PERIOD
No. of Enodes
------- ------------- ---- ------ --------------
-------------
54:7f:ee:37:34:40 Po 22 100 0e:fc:00 4000
2
show fip-snooping fcf Command Description
Field Description
FCF MAC MAC address of the FCF.
FCF Interface Slot/port number of the interface to which the FCF is connected.
VLAN VLAN ID number used by the session.
FC-MAP FC-Map value advertised by the FCF.
ENode Interface Slot/ number of the interface connected to the ENode.
FKA_ADV_PERIOD Period of time (in milliseconds) during which FIP keep-alive
advertisements are transmitted.
No of ENodes Number of ENodes connected to the FCF.
FC-ID Fibre Channel session ID assigned by the FCF.
show fip-snooping statistics (VLAN and port) Command Example
Dell# show fip-snooping statistics interface vlan 100
Number of Vlan Requests :0
Number of Vlan Notifications :0
Number of Multicast Discovery Solicits :2
Number of Unicast Discovery Solicits :0
Number of FLOGI :2
Number of FDISC :16
Number of FLOGO :0
Number of Enode Keep Alive :9021
FIP Snooping
79
Vue de la page 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 313 314

Commentaires sur ces manuels