Dell PowerEdge C6100 Guide de l'utilisateur Page 1

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Serveurs Dell PowerEdge C6100. Dell PowerEdge C6100 Reference Guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Management Controller

Dell™ PowerEdge™ Systems Using the Baseboard Management Controller www . d e l l . c o m | su

Page 2

10 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m 2 In the Modify Alert window, complete the following

Page 3 - Contents

11 Using the Baseboard Management Controller Users The User List window displays the current list of configured users and allows you to add, modify,

Page 4

12 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m To add a user, complete these steps: 1 From the User

Page 5

13 Using the Baseboard Management Controller Table 1-5. Power Control Options Radio Button Description Reset Server Reboot server without powe

Page 6 - Using the Web User Interface

14 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Updating the BMC Firmware Through the GUI Before beginn

Page 7 - Remote Management Controller

15 Using the Baseboard Management Controller 9 When the upgrade is complete, the following message appears. Languages The Languages menu opti

Page 8

16 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m 2 Start the firmware update through TFTP by typing t

Page 9

17 Using the Baseboard Management Controller JViewer Menu The JViewer menu provides access to additional functions, outlined in the following tables

Page 10 - Network

18 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-9. Options Menu Items Menu Options Descrip

Page 11

19 Using the Baseboard Management Controller Table 1-12. BMC Messaging Support Commands (NETFUN: 06H, 07H) Commands NetFn CMD O/M Supported Get

Page 12 - Remote Control

Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

Page 13 - Maintenance

20 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-13. Firmware, Firewall and Discovery Command

Page 14

21 Using the Baseboard Management Controller Table 1-15. IMPI LAN Commands (NETFUN: 0CH, 0DH) Commands NetFn CMD O/M Supported Set LAN Configu

Page 15 - Languages

22 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-18. BMC Watchdog Timer Commands (NETFUN: 06H

Page 16 - Running Virtual Media

23 Using the Baseboard Management Controller Table 1-21. PEF and Alerting Commands (NETFUN: 04H, 05H) Commands NetFn CMD O/M Supported Get PEF C

Page 17 - JViewer Menu

24 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-23. SDR Repository Commands (NETFUN: 0AH, 0B

Page 18

25 Using the Baseboard Management Controller Table 1-25. Sensor Device Commands (NETFUN: 04H, 05H) Commands NetFn CMD O/M Supported Get Device SD

Page 19

26 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-26. Firmware Commands (NETFUN: 08H, 09H) Co

Page 20

27 Using the Baseboard Management Controller Table 1-27. Firmware Commands (NETFUN: 08H, 09H) Commands NetFn CMD Request and Response Get Upda

Page 21

28 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-28. Dell OEM Commands (NETFUN: 2CH, 2DH) Co

Page 22

29 Using the Baseboard Management Controller Table 1-29. Dell OEM Commands (NETFUN: 2EH, 2FH) Commands NetFn CMD Request and Response OemSetUboot

Page 23

Contents 3 Contents Intelligent Platform Management Interface . . . . . . . . . . . . . . . . . . . . 5 Baseb

Page 24

30 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-30. Dell OEM Commands (NETFUN: 30H, 31H) Co

Page 25

31 Using the Baseboard Management Controller Table 1-31. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response Set Extend

Page 26

32 Using the Baseboard Management Controller Table 1-32. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response Restore to

Page 27

33 Using the Baseboard Management Controller Table 1-33. Dell OEM Commands (NETFUN: 30H, 31H) Commands NetFn CMD Request and Response SETSYSTEMG

Page 28 - Byte 3 — Number

34 Using the Baseboard Management Controller www . del l . c o m | s u ppo rt. d e ll. c o m Table 1-35. Vendor OEM Commands (NETFUN: 34H, 35H

Page 29

35 Using the Baseboard Management Controller Table 1-36. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response SetFanCon

Page 30

36 Using the Baseboard Management Controller Table 1-37. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response SetFSCTab

Page 31

37 Using the Baseboard Management Controller Table 1-38. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response OEMPICmod

Page 32

38 Using the Baseboard Management Controller Table 1-39. Vendor OEM Commands (NETFUN: 34H, 35H) Commands NetFn CMD Request and Response Get Disab

Page 33

39 Using the Baseboard Management Controller Chassis Control Command Implementation Table 1-40. Chassis Control Command (NetFn=00/01, Cmd=02h) R

Page 34

4 Contents SSH/Telenet Enable and Disable 56 VLAN ID 57 BMC/BIOS Version Information. 58 BIOS Version Information 59

Page 35

40 Using the Baseboard Management Controller Entity ID and Instance Table Table 1-41. Entity ID and Instance Table Entity ID Entity Instance

Page 36

41 Using the Baseboard Management Controller 2Ah FCB Ambient1 Temperature (01h) Threshold (01h) 2Bh FCB Ambient2 www . del l . com | s u ppo rt.

Page 37

42 Using the Baseboard Management Controller 51h VCORE 1 Voltage (02h) Threshold (01h) 52h VCORE 2 Table 1-44. Sensor Summary Sensor Number S

Page 38

43 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-45. Sensor Summary Sensor Number Sensor Nam

Page 39

44 Using the Baseboard Management Controller Table 1-46. Sensor Summary Sensor Number Sensor Name Sensor Type Event/Reading Type Offset A3h PSU 1 P

Page 40 - Entity ID and Instance Table

45 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Threshold Settings and Converting Formulas Table 1-47.

Page 41 - Sensor Summary

46 Using the Baseboard Management Controller Table 1-48. Threshold Settings and Converting Formulas Sensor Number Sensor Name The Converting Fo

Page 42

47 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-49. Threshold Settings and Converting Formul

Page 43

48 Using the Baseboard Management Controller Power Throttling Function

Page 44

49 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Power Throttling Configuration in BIOS Setup Utility Be

Page 45

5 Using the Baseboard Management Controller Intelligent Platform Management Interface The Intelligent Platform Management Interface (IPMI) defines a

Page 46

50 Using the Baseboard Management Controller Extended Configurations Table 1-50. Configuration ID = 02h, NIC Attribute ID Size Description

Page 47

51 Using the Baseboard Management Controller Lockout Window 3 2 Specifies the window, in second, during which if the consecutive maximum number of

Page 48 - Power Throttling Function

52 Using the Baseboard Management Controller Table 1-54. Configuration ID = 0Ch, WEB Server Configuration Attribute ID Size Description Web Se

Page 49

53 Using the Baseboard Management Controller Entity 3 1 Specifies the entity of the controller. 0: BMC 1: SYSTEM (BIOS) 2: PDB 3

Page 50 - Extended Configurations

54 Using the Baseboard Management Controller Table 1-58. Configuration ID = 11h, Power Management Attribute ID Size e Description Power

Page 51

55 Using the Baseboard Management Controller Appendix SSH/Telnet Enable and Disable • Reserved extended configuration (NetFn: 30H CMD:01H) • Set/Get

Page 52

56 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Set SSH/Telnet enable: • Reserved extended configuratio

Page 53

57 Using the Baseboard Management Controller VLAN ID Use the LAN configuration command parameter 14H to set or get the VLAN ID. For additional infor

Page 54

58 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m BMC/BIOS Version Information The Get Device command is

Page 55 - Appendix

59 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m BIOS Version Information The BIOS enables the system in

Page 56 - Examples:

6 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Watchdog and Automatic System Recovery The BMC watchdog

Page 57 - VLAN ID

7 Using the Baseboard Management Controller Remote Management Controller The first time you access the Dell™ Remote Management Controller, you are pr

Page 58 - BMC/BIOS Version Information

8 Using the Baseboard Management Controller www . del l . com | s u ppo rt. d e ll. c o m Table 1-2. List FRU Option Chassis Information Board

Page 59 - Example:

9 Using the Baseboard Management Controller • Set the email server IP address for sending alert notifications (SMTP button). • View information, c

Commentaires sur ces manuels

Pas de commentaire