Using the Baseboard Management Controller
2Ah
FCB Ambient1
Temperature (01h)
Threshold (01h)
2Bh
FCB Ambient2
www
. del l . com | s u ppo rt. d e ll. c o
m
Table 1-
42
. Entity ID and Instance Table
Entity ID
Entity Instance
Entity Name
Sensor Numbers
01h
PS Current
A1h
02h
PSU 1 POUT
A3h
0Ah (Power Supply)
03h
PSU 2 POUT
A4h
08h
PSU 1 Present
A6h
09h
PSU 2 Present
A7h
Sensor Summary
In the
Offset
column:
AM =
Assertion
mask
DM =
Deassertion
mask
RM =
Reading
mask
SC =
Sensor
capabilities
SI =
Sensor
initialization
TM =
Settable/Readable threshold
mask
Table 1-
43
. Sensor Summary
Sensor
Number
Sensor Name Sensor Type Event/Reading Type Offset
21h MLB TEMP1 Temperature (01h) Threshold (01h) SI: 7Fh
22h MLB TEMP 2
23h MLB TEMP 3
61h Processor 1
Temp
62h Processor 2
Temp
SC: E8h
AM:
0A80h DM:
7A80h TM:
3838h
Temperature (01h) Threshold (01h) SI: 7Fh SC:
E8h AM:
0A80h DM:
7A80h TM:
3838h
SI: FCh
SC:
E8h AM:
0200h DM:
2000h TM:
3030h