Dell PERC 4/DC Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel informatique Dell PERC 4/DC. Dell PERC 4/DC User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 92
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DC
User's Guide
Overview
RAID Controller Features
Hardware Installation
Configuring the RAID Controller
BIOS Configuration Utility and Dell Manager
Troubleshooting
Appendix A: Regulatory Notice
Glossary
Information in this document is subject to change without notice.
©2004DellInc.Allrightsreserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, and Dell OpenManage are trademarks of Dell Inc. Microsoft and Windows are registered trademarks of Microsoft
Corporation. Intel is a registered trademark of Intel Corporation. Novell and NetWare are registered trademarks of Novell Corporation. Red Hat is a registered trademark of Red Hat,
Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
Model PERC 4
Release: July 2004
PartNumber:D8096Rev.A00
Vue de la page 0
1 2 3 4 5 6 ... 91 92

Résumé du contenu

Page 1 - User's Guide

Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser's Guide Overview RAID Controller Features Hardware Installation Configurin

Page 2 - Overview

Installation Steps This section provides instructions for installing the RAID controllers. Step 1 Unpack the Controller  Unpack and remove the

Page 3 - RAID Controller Features

 Table 3-1.PERC4/SCJumperandConnectorDescriptions Figure 3-2. PERC 4/DC Controller Layout   Table 3-2.PERC4/DCJumperandConnector

Page 4 - Background Initialization

Figure 3-3. PERC 4e/DC Controller Layout   Table 3-3.PERC4e/DCJumperandConnectorDescriptions (Dirty Cache LED) device. Optional. J4 SCS

Page 5

Step 4 Install the RAID Controller  Perform the following steps to install the controller: 1. Select a PCI slot for PERC 4/SC or PERC 4/DC, or a

Page 6 - LED Operation

Step 5 Connect SCSI Cables and SCSI Devices Connect the SCSI cables to the SCSI connectors and SCSI devices. Connect SCSI Devices Perform the

Page 7

Step 6 Set Target IDs Set target identifiers (TIDs) on the SCSI devices. Each device in a channel must have a unique TID. Non-disk devices should ha

Page 8

Step 8 Start the System Replace the system cover and reconnect the AC power cords. Turn power on to the host system. Set up the power supplies so t

Page 9

 Table 3-6.FirmwareInitializationStates Step 9 Run the BIOS Configuration Utility or Dell Manager Press <Ctrl><M> when prompted d

Page 10 - Installation Steps

Back to Contents Page Configuring the RAID Controller Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide Configu

Page 11

In this example, data is striped across the disks until 40 GB on Disks A, B, and C are completely full. This leaves 20 GB of disk space on Disk C. Dat

Page 12

Back to Contents Page Overview Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide Overview of PERC 4/SC, 4/DC, a

Page 13

Device Configuration The following contain tables you can fill out to list the devices assigned to each channel. The PERC 4/SC controller has one ch

Page 14 - Cable Suggestions

 Table 4-5.ConfigurationforSCSIChannel1 Setting Hardware Termination  The SCSI bus is an electrical transmission line and must be terminate

Page 15 - Step 7 Set SCSI Termination

Hot Spares Any hard drive that is present, formatted, and initialized, but is not included in an array or logical drive, can be designated as a hot

Page 16 - Step 8 Start the System

Logical Drive Configuration Use Table4-6 to list the details for each logical drive that you configure.  Table 4-6.LogicalDriveConfiguration

Page 17

Table 4-7.PhysicalDrivesRequiredforEachRAIDLevel Summary of RAID Levels RAID 0 uses striping to provide high data throughput, especially f

Page 18

Figure4-2 shows the example of a RAID 50 span with three RAID 5 arrays of different sizes. (Each array can have from three to 14 hard disks.) Data is

Page 19 - Physical Device Layout

Back to Contents Page   Storage space  RAID 0, RAID 5  Data redundancy  RAID 5, RAID 10, RAID 50  Hard drive performance and throughput  

Page 20 - Device Configuration

Back to Contents Page BIOS Configuration Utility and Dell Manager Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGui

Page 21 - Configuring Arrays

1 Logical Drive found on the Host Adapter Adapter BIOS Disabled, No Logical Drives handled by BIOS 0 Logical Drive(s) handled by BIOS Press <

Page 22 - Configuring Logical Drives

l <Shift><2> for <F2> l <Shift><3> for <F3> l <Shift><4> for <F4> l <Shift><5&g

Page 23 - Assigning RAID Levels

Back to Contents Page RAID Controller Features Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide Hardware Requi

Page 24 - Summary of RAID Levels

The drive displays as HOTSP. 5. Save the configuration. Objects Menu 1. On the Management Menu select Objects—> Physical Drive. A physical

Page 25 - Optimizing Storage

Using Easy Configuration In Easy Configuration, each physical array you create is associated with exactly one logical drive. You can modify the fol

Page 26

13. Set the Read Policy. 14. Set the Cache Policy. 15. Press <Esc> to exit the Advanced Menu. 16. After you define the current logica

Page 27

The Select Configurable Array(s) window appears. It displays the array and array number, such as A-00. 6. Press the spacebar to select the array. 

Page 28 - Starting Dell Manager

Hot key information appears at the bottom of the screen. 2. Press the arrow keys to highlight specific physical drives. 3. Press the spacebar to

Page 29 - <F4> Key

23. Press any key to continue, then respond to the Save prompt. 24. Initialize the logical drives you have just configured. See Initializing Lo

Page 30 - Objects Menu

 To delete logical drives, perform the following steps: 1. Select Objects—> Logical Drive from the Management Menu. The logical drives displa

Page 31 - Using Easy Configuration

Manual Rebuild – Rebuilding an Individual Drive 1. Select Objects—> Physical Drive from the Management Menu. A device selection window display

Page 32 - Using New Configuration

The pre-loaded drive should now become an array element. 7. Press <Enter>. You have now declared the pre-loaded drive as a one-disk array.

Page 33

A progress graph for each selected logical drive displays. 6. When the check is finished, press any key to clear the progress display. 7. Press &l

Page 34

 Cache Memory 64 MB of cache memory resides in a memory bank for PERC 4/SC and 128 MB for PERC 4/DC and PERC 4e/DC. The RAID controller supports w

Page 35 - Deleting Logical Drives

Back to Contents Page Troubleshooting Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide General Problems BIOS

Page 36 - Clearing Physical Drives

BIOS Boot Error Messages Table6-2 describes error messages about the BIOS that can display at bootup, the problems, and suggested solutions.  Tab

Page 37 - Manual Rebuild – Batch Mode

Other Potential Problems Table6-3 describes other problems that can occur.  Table 6-3.OtherPotentialProblems Cache Migration To move cache

Page 38 - Checking Data Consistency

3. Transfer the cache to the new controller and connect the drives in the same order as they were connected on the previous adapter. This ensures

Page 39

Back to Contents Page Appendix A: Regulatory Notice Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide FCC Notic

Page 40 - Troubleshooting

l Product name: Dell PowerEdge Expandable RAID Controller 4 Controller l Company name: Dell Inc. Regulatory Department One Dell Way Round Rock,

Page 41 - BIOS Boot Error Messages

Back to Contents Page 

Page 42 - Cache Migration

Back to Contents Page Overview Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide Overview of PERC 4/SC and 4/DC Docum

Page 43 - Audible Warnings

Back to Contents Page RAID Controller Features Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide Hardware Requirements

Page 44 - Class B

Cache Memory 64 MB of cache memory resides in a memory bank for PERC 4/SC and 128 MB for PERC 4/DC. The RAID controller supports write-through or wr

Page 45 - VCCI Class B Statement

 Configuration Features Table2-3 lists the configuration features for the RAID controller.  Table 2-3.ConfigurationFeatures 1Hotswapofdri

Page 46 - Back to Contents Page

Table2-3 lists the configuration features for the RAID controller.  Table 2-3.ConfigurationFeatures Firmware Upgrade You can download the lat

Page 47

Table2-4 lists the drive roaming features for the RAID controller.  Table 2-4. Features for Drive Roaming Drive Migration Drive migration is th

Page 48

Table 2-7.ArrayPerformanceFeatures Fault Tolerance Features Table2-8 describes the fault tolerance capabilities of the RAID controller.  Tab

Page 49 - Configuration Features

l Red Hat Linux See the CERC and PERC RAID Controllers Operating System Driver Installation Guide for more information about the drivers. SCSI Fir

Page 50 - SMART Hard Drive Technology

Back to Contents Page Hardware Installation Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide Requirements Quick Inst

Page 51 - Array Performance Features

Unpack and remove the controller and inspect it for damage. If the controller appears damaged, or if any items listed below are missing, contact your

Page 52 - Software Utilities

PERC 4/DC Jumpers and Connectors Figure 3-2. PERC 4/DC Controller Layout   Table 3-2.PERC4/DCJumperandConnectorDescriptions With jumper

Page 53 - RAID Management Utilities

Step 4 Install the RAID Controller Perform the following steps to install the controller: 1. Select a 3.3-V PCI slot and align the controller PCI

Page 54 - Hardware Installation

4. The host controller has a SCSI ID of 7. 5. Connect the cable to the devices.  Cable Suggestions System throughput problems can occur if t

Page 55 - Step 3 Set Jumpers

Step 8 Start the System Replace the system cover and reconnect the AC power cords. Turn power on to the host system. Set up the power supplies so

Page 56

Drive roaming occurs when the hard drives are changed to different channels on the same controller. When the drives are placed on different channels,

Page 57

The BIOS Configuration Utility prompt times out after several seconds. The host controller number, firmware version, and cache SDRAM size display in

Page 58

Step 11 Install the Operating System Driver Operating system drivers are provided on the Dell OpenManage Systems Management CD that accompanies your

Page 59

Back to Contents Page Configuring the RAID Controller Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide Configuring SCS

Page 60

Logical drive number/ drive number   Manufacturer/model number   Firmware level   Target ID   Device type   Logical drive nu

Page 61

Device Configuration The following contain tables you can fill out to list the devices assigned to each channel. The PERC 4/SC controller has one ch

Page 62

Setting Hardware Termination  The SCSI bus is an electrical transmission line and must be terminated properly to minimize reflections and losses. T

Page 63

5. Select the RAID level, cache policy, read policy, and write policy. 6. Save the configuration. 7. Initialize the system drives. 8. Insta

Page 64

Assigning RAID Levels Only one RAID level can be assigned to each logical drive. Table4-5 shows the minimum and maximum number of drives required.

Page 65

Optimizing Data Storage Data Access Requirements Each type of data stored in the disk subsystem has a different frequency of read and write acti

Page 66 - Logical Drive Configuration

Back to Contents Page BIOS Configuration Utility and Dell Manager Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide Sta

Page 67

Array Performance Features Table2-6 displays the array performance features for the RAID controller.  Table 2-6.ArrayPerformanceFeatures Faul

Page 68 - Optimizing Data Storage

0 Logical Drive(s) handled by BIOS Press <Ctrl><M> to Enable BIOS For each controller in the host system, the firmware version, dynami

Page 69

Configuring Arrays and Logical Drives 1. Designate hot spares (optional). See Designating Drives as Hot Spares in this section for more informati

Page 70

The selected drive displays as HOTSP. Creating Arrays and Logical Drives Configure arrays and logical drives using Easy Configuration, New Configur

Page 71

In Easy Configuration, each physical array you create is associated with exactly one logical drive. You can modify the following parameters: l RAID

Page 72

 17. Repeat step 2 through step 16 to configure another array and logical drive. The RAID controller supports up to 40 logical drives per control

Page 73

 7. Repeat step2 through step6 to create another array or go to step8 to configure a logical drive. 8. Press <F10> to configure a logica

Page 74

The selected drive changes from READY to ONLIN A[array number]-[drive number]. For example, ONLIN A2-3 means array 2 with hard drive 3. 4. Add physi

Page 75

Drive Roaming Drive roaming (also known as configuration on disk) occurs when the hard drives are changed to different channels on the same controll

Page 76

 To delete logical drives, perform the following steps: 1. Select Objects—> Logical Drive from the Management Menu. The logical drives displa

Page 77

Table 5-2. Rebuild Types Manual Rebuild – Rebuilding an Individual Drive 1. Select Objects—> Physical Drive from the Management Menu. A devic

Page 78

The RAID controller firmware handles all RAID and SCSI command processing and supports the features described in Table2-8.  Table 2-8.SCSIFirmwar

Page 79

You have now declared the pre-loaded drive as a one-disk array. 8. Set the Read Policy and Cache Policy on the Advanced Menu. 9. Exit the Advance

Page 80

Reconstructing Logical Drives A reconstruction occurs when you change the RAID level of an array or add a physical drive to an existing array. Perfo

Page 81

Back to Contents Page Troubleshooting Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide General Problems BIOS Boot Er

Page 82

BIOS Boot Error Messages Table6-2 describes error messages about the BIOS that can display at bootup, the problems, and suggested solutions.  Tab

Page 83

Other Potential Problems Table6-3 describes other problems that can occur.  Table 6-3.OtherPotentialProblems Cache Migration To move cache

Page 84

See RAID Controller Features for information about the jumper to set to clear NVRAM. l Make sure that the configuration data on the disks is intact.

Page 85

Back to Contents Page Appendix A: Regulatory Notice Dell™PowerEdge™ExpandableRAIDController4/SCand4/DCUser'sGuide FCC Notices (U.S.

Page 86

l Product name: Dell PowerEdge Expandable RAID Controller 4 Controller l Company name: Dell Inc. Regulatory Department One Dell Way Round Rock,

Page 87

Back to Contents Page 

Page 88

Back to Contents Page Glossary Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide A •C •D •F •G •H •I •L •

Page 89 - Glossary

Back to Contents Page Hardware Installation Dell™PowerEdge™ExpandableRAIDController4/SC,4/DC,and4e/DCUser'sGuide Requirements Qu

Page 90

Disk Subsystem A collection of disks and the hardware that connects them to one or more host systems. The hardware can include an intelligent controll

Page 91

Multi-threaded Having multiple concurrent or pseudo-concurrent execution sequences. Used to describe processes in systems. Multi-threaded processes al

Page 92

SCSI (small computer system interface) A processor-independent standard for system-level interfacing between a system and intelligent devices, includi

Modèles reliés PERC 4E/DC | PERC 4/SC |

Commentaires sur ces manuels

Pas de commentaire