4. In the Host Root area, do one of the following:
For hosts already configured and enabled for Active Directory on which you want to use Active Directory,
select the Use Active Directory check box; otherwise skip down to configure your Host Credentials.
In the Active Directory User Name text box, type the user name. Type the username in one of these formats:
domain\username or username@domain. The user name is limited to 256 characters. Refer to Microsoft
Active Directory documentation for user name restrictions.
In the Active Directory Password text box, type the password. The password is limited to 127 characters.
In the Verify Password text box, type the password again.
Perform one of the following actions:
* To download and store the Host certificate and validate it during all future connections, select the
Enable Certificate Check check box .
* To not store and perform the Host certificate check during all future connections, clear the Enable
Certificate Check check box.
To configure Host Credentials without Active Directory, do the following:
In the User Name text box, the user name is root. This is the default username and you cannot change the
username. However, if the Activate directory is set, you can choose any Active directory user not just root.
In the Password text box type the password. The password is limited to 127 characters.
NOTE: The OMSA credentials are the same credentials used for ESX and ESXi hosts.
In the Verify Password text box, type the password again.
Perform one of the following actions:
* To download and store the Host certificate and validate it during all future connections, select the
Enable Certificate Check check box.
* To not store and perform the Host certificate check during all future connections, clear the Enable
Certificate Check check box
5. Click Next.
6. In the Associated Hosts page, select the hosts for the connection profile and click OK.
7. To test the connection profile, select one or more hosts and select the Test Connection button. This step is optional.
This is used to check whether the Host and iDRAC credentials are correct or not.
8. To complete the profile, click Next. For servers that do not have either an iDRAC Express or Enterprise card, the
iDRAC test connection result states Not Applicable for this system.
Scheduling Inventory Jobs [Wizard]
The inventory schedule configuration is similar between the Configuration Wizard and from the OpenManage Integration
under Manage section, Settings option.
NOTE: To make sure that the OpenManage Integration for VMware vCenter continues to display updated
information, it is recommended that you schedule a periodic inventory job. The inventory job consumes minimal
resources and will not degrade host performance.
NOTE: Chassis gets discovered automatically once the inventory for all hosts is run. If the chassis is added to a
chassis profile, then the chassis inventory automatically runs. In a SSO environment having multiple vCenters, the
chassis inventory runs automatically with every vCenter when the inventory for any vCenter is run at a scheduled