Page 1 - TROUBLESHOOTING GUIDE

Dell™ PowerVault™ 51F 8-Port Fibre Channel SwitchINSTALLATION ANDTROUBLESHOOTING GUIDEBE DIRECTwww.dell.com™™

Page 2

xii•When transporting a sensitive component, first place it in an antistatic container or packaging.•Handle all sensitive components in a static-safe

Page 3 - Safety Instructions

4-38 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideLSDbShowThe LSDbShow command displays domain Link State Dat

Page 4 - Additional Safety Precautions

support.dell.com PowerVault 51F Commands 4-39mcastShowThe mcastShow command. Without parameters, it shows multicast tree information for all the multi

Page 5

4-40 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuiderouteHelpThe following example shows the routeHelp command

Page 6

support.dell.com PowerVault 51F Commands 4-41The following is an example of the topologyShow command screen.uRouteConfigThe uRouteConfig command allow

Page 7

4-42 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideuRouteShowFigure 4-5 shows the uRouteShow command, which di

Page 8

support.dell.com Troubleshooting 5-1CHAPTER 5TroubleshootingThis chapter discusses troubleshooting, diagnostic testing, and error messages, including

Page 9

5-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideTo retest a port which has been marked BAD, clear the port a

Page 10 - Ergonomic Computing Habits

support.dell.com Troubleshooting 5-3Front-Panel LED Port IndicatorsThe color and flash speed of each port’s LED, as described in Table 5-2, indicates

Page 11

5-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide7. Fabric analysis; the switch checks for ports connected to

Page 12

support.dell.com Repair and Replacement 6-1CHAPTER 6Repair and ReplacementThis chapter covers the recommended and supported field repair and replaceme

Page 13 - About This Guide

xiii1Monitor screen at or below eye level2Wrists relaxed and flat3Arms at desk level4Feet flat on the floor5Monitor and keyboard positioned directly i

Page 14 - Typographical Conventions

6-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideRemoving the Power SupplyTo remove the power supply, you mus

Page 15

support.dell.com Repair and Replacement 6-3Replacing a GBIC ModuleGBIC modules are installed and removed by inserting them into the system board from

Page 16

6-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideReplacing the Fan AssemblyReplacing the fan assembly involve

Page 17 - Contents

support.dell.com Repair and Replacement 6-5Figure 6-5. Removing the Fan AssemblyRemoving the Fan Assembly1. Disconnect the fan assembly’s wiring harn

Page 18

6-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide3. Attach the assembly’s wiring harness to the center connec

Page 19

support.dell.com Repair and Replacement 6-710. Remove the new system board from its antistatic bag and place the old system board into the bag.Figure

Page 20

6-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide9. Reinstall the GBICs. See “Installing a GBIC Module” found

Page 21

support.dell.com Repair and Replacement 6-9Installing the New Switch Components1. Install the system board. See “Installing the System Board,” found e

Page 22

6-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

Page 23

support.dell.com Getting Help 7-1CHAPTER 7Getting HelpThis chapter describes the tools Dell provides to help you when you have a problem with your sys

Page 25

7-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideHelp ToolsDell provides a number of tools to assist you. The

Page 26

support.dell.com Getting Help 7-3AutoTech ServiceDell’s automated technical support service—AutoTech—provides recorded answers to the questions most f

Page 27

7-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideProblems With Your Order If you have a problem with your

Page 28

support.dell.com Getting Help 7-5Before You CallNOTE: Have your Express Service Code ready when you call. The code helps Dell’s automated-support tele

Page 29 - 51F Switch

7-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideDiagnostics ChecklistFigure 7-1. Diagnostics ChecklistName:

Page 30 - Power Requirements

support.dell.com Getting Help 7-7Dell Contact Numbers When you need to contact Dell, use the telephone numbers, codes, and electronic addr

Page 31 - Rack Mounting

7-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideTable 7-1. International Dialing CodesCountry (City)Interna

Page 32 - Installing the Switch

support.dell.com Getting Help 7-9Table 7-2. Dell Contact NumbersSpain (Madrid) 07 34 91Sweden (Upplands Vasby) 009 46 8Switzerland (Geneva) 00 41 22T

Page 33

7-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideBelgium(Brussels)Technical Support. . . . . . . . . . . . .

Page 34

support.dell.com Getting Help 7-11China(Xiamen)Customer Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . toll free: 800 858

Page 35

xvPrefaceAbout This GuideThis guide is intended for anyone who is installing and managing a Dell PowerVault 51F 8-Port Fibre Channel Switch. It is to

Page 36 - Installing the Outer Slides

7-12 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideFrance(Paris/Montpellier)Technical Support. . . . . . . . .

Page 37

support.dell.com Getting Help 7-13Ireland(Bray)Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-85

Page 38

7-14 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideKorea(Seoul)Technical Support. . . . . . . . . . . . . . .

Page 39

support.dell.com Getting Help 7-15Mexico(Colonia Granada)NOTE: Customers in Mexico call the U.S.A. for access to the Automated Order-Status Sys-tem an

Page 40 - Stand-Alone Mounting

7-16 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuidePoland(Warsaw)Technical Support. . . . . . . . . . . . . .

Page 41 - Length GBIC Module

support.dell.com Getting Help 7-17Spain(Madrid)Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Page 42 - Serial Port Connection

7-18 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideU.K.(Bracknell)Technical Support. . . . . . . . . . . . . .

Page 43 - Ethernet port

support.dell.com Getting Help 7-19U.S.A.(Austin, Texas)Automated Order-Status System . . . . . . . . . . . . . . . . . . . . . toll free: 1-800-433-90

Page 44 - Table 1-2. Cabling Pinouts

7-20 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

Page 45

support.dell.com Error Messages A-1APPENDIX AError MessagesThis appendix explains the error message format, error message by firmware module, and othe

Page 46

xviWarranty and Return Policy InformationDell Computer Corporation (“Dell”) manufactures its hardware products from parts and components that are new

Page 47 - PowerVault 51F Topologies

A-2 Installation and Troubleshooting GuideFigure A-1. errShow Command ExampleTo display error messages via Telnet:1. From the prompt, type errShow.2.

Page 48 - Universal Ports

support.dell.com Error Messages A-3LSRLEN (2) The local switch is trying to cre-ate a Link State Update that exceeds the max-imum length.Check that al

Page 49 - Sample Fabric Topologies

A-4 Installation and Troubleshooting GuideHLO INVHLO (1) The path selec-tion task has received a HELLO message with an invalid parameter from a neighb

Page 50 - Two-Switch Sample Topology

support.dell.com Error Messages A-5NBFSM NGBRSTATE (2) An error occurred in the neighbor Finite State.Check the neighbor’s state with the nbrStateShow

Page 51

A-6 Installation and Troubleshooting GuidePanic ErrorsThis module includes errors that cause a system panic to occur. A system panic causes the switch

Page 52

support.dell.com Error Messages A-7MQ-QWRITE ErrorThe software includes several message queues that are used for inter-task communi-cation. Each queue

Page 53 - Managing the PowerVault 51F

A-8 Installation and Troubleshooting GuideFigure A-2. MQ-QWRITE Error ExampleThe most notable parameters are:•The ID of the task that attempted to se

Page 54 - (Ethernet)

support.dell.com Error Messages A-9For information on executing these commands, contact Dell for technical assistance.Other Possible ErrorsThis sectio

Page 55 - Managing Via Telnet

A-10 Installation and Troubleshooting GuideDiag_Flt: the port failed diagnostics (defective G_Port card or motherboard)Port is OK (Solid Green LED)

Page 56 - OpenManage

support.dell.com Glossary 1GlossaryThe following terms relate to the switch and Fibre Channel connections.Definition of TermsAlias ServerA fabric soft

Page 57

xvii•Syntax lines consist of a command and all its possible parameters. Commands are displayed in lowercase bold; variable parameters (those for which

Page 58

2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideFL_PortThe FL_Port is the fabric access port used to connect N

Page 59

support.dell.com Index 1IndexAADDBRANCH (2), A-4ADDPATH (1), A-5ADDPORT (3), A-4agtcfgSet command, 4-4agtcfgShow command, 4-5aliasShow command, 4-5arb

Page 60 - Name Server

2 Dell Dimension Systems User’s Guidecommands (continued)interfaceShow, 4-35iodReset, 4-37iodSet, 4-37ipAddrSet, 4-21ipAddrShow, 4-22login, 4-22logout

Page 61

support.dell.com Index 3errors (continued)NOPARENT (2), A-4NOPARENTLSR (2), A-4QREAD (1), A-5QWRITE (1), A-5RELICPDB (2), A-5REMDOMAIN (2), A-3REMPORT

Page 62

4 Dell Dimension Systems User’s GuideipAddrSet command, 4-21setting address, 1-17ipAddrShow command, 4-22LLEDsflash speed and color, 5-2, 5-3green, 5-

Page 63 - PowerVault 51F Commands

support.dell.com Index 5QQREAD (1), A-5QWRITE (1), A-5Rreboot command, 4-28RELICPDB (2), A-5REMDOMAIN (2), A-3REMPORT (3), A-4replacement partschassis

Page 64

6 Dell Dimension Systems User’s Guidetopologycascading, 2-2fault-tolerant, 2-5sample two-switch fabric, 2-4single switch fabric, 2-3switches in fabric

Page 65

xviii

Page 66

xixContentsChapter 1 Installing the Dell PowerVault 51F Switch . . . . . . . . . 1-1Unpacking the PowerVault 51F Switch . . . . . . . . . . . . . . .

Page 67

xxChapter 2 PowerVault 51F Topologies. . . . . . . . . . . . . . . . . . . . . 2-1Fabric Elements . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 68

xxierrDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15errShow . . . . . . . . . . .

Page 69

____________________Information in this document is subject to change without notice.© 2000 Dell Computer Corporation. All rights reserved.Reproductio

Page 70

xxiitopologyShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-40uRouteConfig. . . . . . . . . .

Page 71 - Field Type Default Range

xxiiiChapter 7 Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1Technical Assistance . . . . . . . . . . . . . . . . .

Page 72 - Table 4-5. Fabric Parameters

xxivFigure 2-2. Fabric Topology Sample With Three Connections Between Two Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 73

xxvTable 4-20. interfaceShow Command Static Field Descriptions. . . . . . . . . . . . . 4-35Table 4-21. Neighbor Data Structure Field Descriptions. .

Page 75 - Table 4-8. System Services

iFigure 1-1. PowerVault 51F Switch Front View . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Figure 1-2. Rack Kit Contents . . . . . . . . .

Page 77

iTable 1-1. Cabling Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13Table 1-2. Cabling Pinouts . . . . . . .

Page 79 - Fabric Element Description

support.dell.com Installing the Dell PowerVault 51F Switch 1-1CHAPTER 1Installing the Dell™ PowerVault™ 51F Switch The complete setup for the Dell Pow

Page 80 - Rebooting

vSafety InstructionsUse the following safety guidelines to ensure your own personal safety and to help protect your computer or storage system from po

Page 81

1-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideNOTE: Do not block the front or back air vents. The switch m

Page 82

support.dell.com Installing the Dell PowerVault 51F Switch 1-3Site LocationThe switch should be installed in a secure or limited access site to contro

Page 83

1-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideBefore You BeginBefore you install your PowerVault 51F switc

Page 84

support.dell.com Installing the Dell PowerVault 51F Switch 1-5Figure 1-2. Rack Kit ContentsRemoving the Doors From the RackYou must remove the front

Page 85 - Table 4-12. nsShow Fields

1-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide Figure 1-3. Opening the Latch on the Door2. Remove the fro

Page 86

support.dell.com Installing the Dell PowerVault 51F Switch 1-7Figure 1-4. Removing the Rack Doors3. Perform steps 1 and 2 to remove the back door fro

Page 87

1-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideAdjusting the Bezel PositionIf you are installing the switch

Page 88

support.dell.com Installing the Dell PowerVault 51F Switch 1-9Figure 1-6. Mounting the Outer Slides in the Rack2. Use four 10-32 x 1/2-inch screws an

Page 89 - Status Description

1-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideInstalling the Switch in the RackTo install the switch in t

Page 90 - Updating flash

support.dell.com Installing the Dell PowerVault 51F Switch 1-11Installing the Cable-Management Arm1. From the back of the rack, pull the switch out ab

Page 91

viWARNING: This system may have more than one power supply cable. To reduce the risk of electrical shock, a trained service technician must discon-nec

Page 92

1-12 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide3. Route the cables along the cable-management arm and secu

Page 93

support.dell.com Installing the Dell PowerVault 51F Switch 1-13Fibre Channel Cable ConnectionsAll network cable connections are on the switch’s front

Page 94 - License Commands

1-14 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideFigure 1-9. Dual SC Fiber-Optic Plug ConnectorThe connecto

Page 95 - Routing Commands

support.dell.com Installing the Dell PowerVault 51F Switch 1-15•VT100•Flow control = Xon/XoffFigure 1-10. Connections for PowerVault 51F SwitchNOTE:

Page 96 - Bitmap Field Description

1-16 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideNOTE: For dust and electrostatic discharge (ESD) protection

Page 97 - Descriptions

support.dell.com Installing the Dell PowerVault 51F Switch 1-17If error conditions are encountered, they are displayed on the local RS-232 serial port

Page 98

1-18 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideFibre Channel Subnetmask [current]: [enter new subnet mask

Page 99

support.dell.com PowerVault 51F Topologies 2-1FILE LOCATION: S:\SYSTEMS\Boxer\rev_i&t\English\50UWDa00\50UWDc20.fmDELL CONFIDENTIAL - Preliminary

Page 100 - LSDbShow

2-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideDELL CONFIDENTIAL - Preliminary 4/6/00FILE LOCATION: S:

Page 101 - (continued)

support.dell.com PowerVault 51F Topologies 2-3DELL CONFIDENTIAL - Preliminary 4/6/00FILE LOCATION: S:\SYSTEMS\Boxer\rev_i&t\English\50UWDa00\

Page 102 - Field Description

vii•If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your Dell authorized servi

Page 103

2-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideDELL CONFIDENTIAL - Preliminary 4/6/00FILE LOCATION: S:

Page 104

support.dell.com PowerVault 51F Topologies 2-5DELL CONFIDENTIAL - Preliminary 4/6/00FILE LOCATION: S:\SYSTEMS\Boxer\rev_i&t\English\50UWDa00\

Page 105 - Troubleshooting

2-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideDELL CONFIDENTIAL - Preliminary 4/6/00FILE LOCATION: S:

Page 106 - Isolating a System Fault

support.dell.com Managing the PowerVault 51F Switch 3-1CHAPTER 3Managing the PowerVault 51F SwitchThis chapter contains general information and exampl

Page 107 - Initialization Steps

3-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideBefore changing any of the factory default settings, become

Page 108

support.dell.com Managing the PowerVault 51F Switch 3-3Figure 3-1. Switch Management MethodsManaging Via TelnetTo make a successful Telnet connection

Page 109 - Repair and Replacement

3-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideDefault UsernameEach Username has a security level associate

Page 110 - Installing the Power Supply

support.dell.com Managing the PowerVault 51F Switch 3-5Dell recommends that you use one of the “ro” communities to set up your trap community and trap

Page 111 - Replacing a GBIC Module

3-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideFabric Element MIB SupportThe following five object groups a

Page 112 - Replacing the Fan Assembly

support.dell.com Managing the PowerVault 51F Switch 3-7Enterprise Specific TrapsThe following Enterprise Specific Traps are supported:•swFault — Indic

Page 113 - Installing a New Fan Assembly

viiiadapter plugs or remove the grounding prong from a cable. If you must use an extension cable, use a three-wire cable with properly grounded plugs.

Page 114 - Replacing the System Board

3-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide2 — Error3 — Warning4 — Informational5 — DebugSee Appendix A

Page 115 - Installing a System Board

support.dell.com Managing the PowerVault 51F Switch 3-9Introducing the PowerVault Switch ManagerUse the PowerVault Fibre Channel Switch Manager (Web i

Page 116 - Replacing the Chassis

3-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide

Page 117

support.dell.com PowerVault 51F Commands 4-1CHAPTER 4PowerVault 51F CommandsThis chapter contains information and examples on managing and monitoring

Page 118

4-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideagtcfgDefault This agtcfgDefault command allows admin to res

Page 119 - Getting Help

support.dell.com PowerVault 51F Commands 4-3Community 4: public (ro)No trap recipient configured yetCommunity 5: common (ro)No trap recipient configur

Page 120 - Help Tools

4-4 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideIn addition, six communities and respective trap recipients

Page 121 - Technical Support Service

support.dell.com PowerVault 51F Commands 4-5agtcfgShowThe agtcfgShow command displays current SNMP agent configuration. The fields are described in Ta

Page 122 - Product Information

4-6 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideconfigureFigures 4-1 through 4-3 show examples of the config

Page 123 - Before You Call

support.dell.com PowerVault 51F Commands 4-7entered at the prompt, as shown in Figure 4-1. The various configuration settings and parameters are descr

Page 124 - Diagnostics Checklist

ix•Move products with care; ensure that all casters and/or stabilizers are firmly con-nected to the computer or storage system. Avoid sudden stops and

Page 125

4-8 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide.Figure 4-2. configure Command Submenusswitch:admin> con

Page 126 - International

support.dell.com PowerVault 51F Commands 4-9Figure 4-3. configure Command Behavior With Out-of-Range or Inappropriate InputsA number of parameters co

Page 127

4-10 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideA listing of the configurable fabric parameters is shown in

Page 128 - Area Local Number or

support.dell.com PowerVault 51F Commands 4-11The switch provides the ability to tune the switch in a specific application, by configur-ing the paramet

Page 129

4-12 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideTable 4-7 describes the arbitrated loop parameters.VC Multi

Page 130

support.dell.com PowerVault 51F Commands 4-13Table 4-8 describes the system services.Table 4-8. System ServicesField Description Defaultrusersd Dynam

Page 131

4-14 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideconfigDefaultThe configDefault command is used to reset som

Page 132

support.dell.com PowerVault 51F Commands 4-15d.MM is the minutese.yy is the year2. Press <Enter> to set the date and time.NOTE: The date functio

Page 133

4-16 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideerrShowThe errShow command displays all detected errors, on

Page 134

support.dell.com PowerVault 51F Commands 4-17fabricShowThe fabricShow command displays a list of switches and multicast alias groups in a fabric. The

Page 135

x•Ensure that proper airflow is provided to components in the rack.•Do not step on or stand on any system/component when servicing other sys-tems/comp

Page 136

4-18 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuidefastbootThe fastboot command initiates a warm reboot that b

Page 137

support.dell.com PowerVault 51F Commands 4-192. Click Start and then click Programs. 3. In the program list, click Dell OpenManage PowerVault Manager,

Page 138

4-20 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideThe help display changes depending on the login user level,

Page 139 - Error Messages

support.dell.com PowerVault 51F Commands 4-21ifShowThe ifShow command displays a summary of currently running tasks. The display includes three sectio

Page 140 - Severity Explanation Action

4-22 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideAfter each prompt, the current value is shown inside bracke

Page 141 - Table A-1. Errors

support.dell.com PowerVault 51F Commands 4-23nsShowThe nsShow command displays local name server information, which includes infor-mation about device

Page 142

4-24 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideThe optional parameter <user name> is a double-quoted

Page 143

support.dell.com PowerVault 51F Commands 4-25portLogClearThe portLogClear command clears the data from the port log. The command syntax is portLogClea

Page 144 - Panic Errors

4-26 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guidestat_ftx Number of frames transmitted from the port.stat_f

Page 145 - MQ-QWRITE Error

support.dell.com PowerVault 51F Commands 4-27psShowThe following example shows the psShow command screen, which displays the power supply status and m

Page 146 - Command Description

xiNOTICE: To help avoid possible damage to the system board, wait 5 sec-onds after turning off the system before removing a component from the system

Page 147 - Other Possible Errors

4-28 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuiderebootThe reboot command reboots the switch to the stored c

Page 148 - Thermometer Error Message

support.dell.com PowerVault 51F Commands 4-29Certain restrictions apply to the length and format of the switch name. Specifically, the name of the swi

Page 149 - Glossary

4-30 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideTable 4-16. switchShow Command Field DescriptionsField Des

Page 150

support.dell.com PowerVault 51F Commands 4-31syslogdIpThe syslogdIp command sets or displays the switches system log daemon IP address. The command sy

Page 151

4-32 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuideuptimeThe uptime command can be used to display the amount

Page 152

support.dell.com PowerVault 51F Commands 4-33Routing CommandsRouting commands allow you to view switch routing information.bcastShowThe following exam

Page 153

4-34 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuidefspfShowThe following example shows the fspfShow command sc

Page 154

support.dell.com PowerVault 51F Commands 4-35 interfaceShowThe interfaceShow command displays FSPF interface information. This includes static informa

Page 155

4-36 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting GuidelastUpTime Last time this interface came up.downCount Numbe

Page 156

support.dell.com PowerVault 51F Commands 4-37iodResetThe iodReset command turns off the in-order delivery option. This command allows out-of-order del