Virtual Disk Specifications For The PERC S100, PERC S110, And S300 Controllers....................................... 217
RAID Levels Supported By The PERC S100, PERC S110, And S300 Controllers............................................. 218
Read Write Cache And Disk Cache Policy Supported By The PERC S100, PERC S110, And S300
Controllers......................................................................................................................................................218
Enclosure Support On The PERC S100, PERC S110, And S300 Controllers.................................................... 219
Supported Features On The Non-RAID Controllers..............................................................................................219
Controller Tasks Supported On The Non-RAID Controllers........................................................................... 219
Battery Tasks Supported By Non-RAID Controllers...................................................................................... 220
Connector Tasks Supported On The Non-RAID Controllers.......................................................................... 220
Physical Disk Tasks Supported On The Non-RAID Controllers......................................................................220
Virtual Disk Tasks Supported By The Non-RAID Controllers.........................................................................221
Enclosure Support On The Non-RAID Controllers......................................................................................... 222
Enclosure And Backplane Features..................................................................................................................... 222
Enclosure And Backplane Tasks....................................................................................................................222
Maximum Supported Configuration For SAS Controllers..................................................................................... 223
21 Determining The Health Status For Storage Components............................................. 225
Health Status Rollup: Battery Is Charging Or Dead.............................................................................................. 225
Health Status Rollup: Physical Disks In A Virtual Disk Are Failed Or Removed................................................... 225
Health Status Rollup: Physical Disks In A Virtual Disk Are Unsupported, Partially, Or Permanently Degraded..226
Health Status Rollup: All Physical Disks In A Virtual Disk Are In Foreign State...................................................226
Health Status Rollup: Some Physical Disks In A Virtual Disk Are In Foreign State..............................................226
Health Status Rollup: Virtual Disk Is Degraded; Physical Disks Are Failed Or Rebuilding................................... 227
Health Status Rollup: Virtual Disk Is Failed...........................................................................................................227
Health Status Rollup: Unsupported Firmware Version......................................................................................... 227
Health Status Rollup: Enclosure Power Supply Failed Or Power Connection Removed......................................228
Health Status Rollup: One Enclosure Fan Is Failed...............................................................................................228
Health Status Rollup: One Enclosure EMM Is Failed............................................................................................228
Health Status Rollup: One Enclosure Temperature Probe Is Failed..................................................................... 229
Health Status Rollup: Lost Both Power Connections To The Enclosure...............................................................229
Health Status Rollup: One Or More Physical Disks Are Failed.............................................................................229
Health Status Rollup: Physical Disk Is Rebuilding................................................................................................ 230