RAID 10 characteristics:
Groups
n
disks as one large virtual disk with a capacity of (
n
/2) disks, where
n
is an even integer.
Mirror images of the data are striped across sets of physical disks. This level provides redundancy through
mirroring.
When a disk fails, the virtual disk still works. The data is read from the surviving mirrored disk.
Improved read performance and write performance.
Redundancy for protection of data.
RAID Level 1-Concatenated (Concatenated Mirror)
RAID 1-concatenated is a RAID 1 disk group that spans across more than a single pair of physical disks. This
configuration combines the advantages of concatenation with the redundancy of RAID 1. No striping is involved in this
RAID type.
NOTE: You cannot create a RAID 1-concatenated virtual disk or reconfigure to RAID 1-concatenated with Storage
Management. You can only monitor a RAID 1- concatenated virtual disk with Storage Management.