122 Troubleshooting
Physical Disk Related Issues
Table 7-4 describes physical disk-related problems you might encounter, with
suggested solutions.
Table 7-4. Physical Disk Issues
Problem Suggested Solution
One of the physical disks in
the disk array is in the
failed state.
Perform the following actions to resolve this problem:
1
Check the backplane for damage.
2
Check the SAS cables.
3
Reseat the physical disk.
4
Contact Dell Technical Support if the problem persists.
Cannot rebuild a fault
tolerant virtual disk.
NOTE: For more
information, see the alert
log for virtual disks.
The replacement disk is too small or not compatible
with the virtual disk. Replace the failed disk with a
compatible good physical disk with equal or greater
capacity.
Fatal error(s) or data
corruption(s) are reported
when accessing virtual
disks.
Contact Dell Technical Support.