Dell PowerEdge Expandable RAID Controller 3 Guide de l'utilisateur Page 117

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 160
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 116
Troubleshooting 117
Invalid SAS topology
detected. Please check your
cable configurations, repair
the problem, and restart your
system.
The SAS cables for your system are
improperly connected. Check the cable
connections and fix problems if any.
Restart the system.
Multibit ECC errors were
detected on the RAID
controller. If you continue,
data corruption can occur.
Contact technical support to
resolve this issue. Press 'X'
to continue or else power off
the system, replace the
controller and reboot.
This error is specific to the PERC 6/i
controller.
Multi-bit ECC errors (MBE) occur in the
memory and can corrupt cached data and
discard it.
CAUTION: MBE errors are serious, as
they cause data corruption and data loss.
In case of MBE errors, contact Dell
Technical Support.
NOTE: A similar message displays when
multiple single-bit ECC errors are detected
on the controller during bootup.
Multibit ECC errors were
detected on the RAID
controller.The DIMM on the
controller needs
replacement. If you continue,
data corruption can occur.
Press 'X' to continue or else
power off the system, replace
the DIMM module, and reboot.
If you have replaced the DIMM
please press 'X' to continue.
This error is specific to the PERC 6/E
controller.
Multi-bit ECC errors (MBE) occur in the
memory and can corrupt cached data and
discard it.
Table 7-1. BIOS Errors and Warnings (continued)
Message Meaning
Dell_PERC6.2_UG.book Page 117 Wednesday, June 24, 2009 6:08 PM
Vue de la page 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 159 160

Commentaires sur ces manuels