Dell OpenManage Server Administrator Version 5.0 Guide de l'utilisateur Page 53

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 52
System Event Log Messages for IPMI Systems 53
Memory Removed
(BANK# DIMM#) presence was
asserted
Information This event is generated when memory is removed from
the system.
Memory Cfg Err
configuration error (BANK#
DIMM#) was asserted
Critical This event is generated when memory configuration is
incorrect for the system.
Mem Redun Gain
redundancy regained
Information This event is generated when memory redundancy is
regained.
Mem ECC Warning
transition to non-critical
from OK
Warning This event is generated when correctable ECC errors
have increased from a normal rate.
Mem ECC Warning
transition to critical from
less severe
Critical This event is generated when correctable ECC errors
reach a critical rate.
Mem CRC Err
transition to non-recoverable
Critical This event is generated when CRC errors enter a
non-recoverable state.
Mem Fatal SB CRC
uncorrectable ECC was
asserted
Critical This event is generated when CRC errors occur while
storing to memory.
Mem Fatal NB CRC
uncorrectable ECC was
asserted
Critical This event is generated when CRC errors occur while
removing from memory.
Mem Overtemp
critical over temperature
was asserted
Critical This event is generated when system memory reaches
critical temperature.
USB Over-current
transition to non-recoverable
Critical This event is generated when the USB exceeds a
predefined current level.
Hdwr version err
hardware incompatibility
(BMC Firmware and CPU
mismatch) was asserted
Critical This event is generated when there is a mismatch
between the BMC firmware and the processor in use
or vice versa.
Table 3-12. BIOS Generated System Events (continued)
Event Message Severity Cause
Vue de la page 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 119 120