Storage Management Message Reference 67
2104 Controller battery is
reconditioning
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 581
2105 Controller battery
recondition is
completed
Ok / Normal Cause: This alert is provided for
informational purposes.
Action: None
1151 582
2106 Smart FPT exceeded Warning /
Non-critical
Cause: A disk on the specified controller has
received a SMART alert (predictive failure)
indicating that the disk is likely to fail in the
near future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up
the data before replacing the disk. Removing
an array disk that is included in a non-
redundant virtual disk will cause the virtual
disk to fail and may cause data loss.
903 585
2107 Smart configuration
change
Critical /
Failure /
Error
Cause: A disk has received a SMART alert
(predictive failure) after a configuration
change. The disk is likely to fail in the near
future.
Action: Replace the disk that has received the
SMART alert. If the array disk is a member of
a non-redundant virtual disk, then back up
the data before replacing the disk. Removing
an array disk that is included in a non-
redundant virtual disk will cause the virtual
disk to fail and may cause data loss.
904 586
Table 4-1. Storage Management Messages (continued)
Event ID Description Severity Cause and Action SNMP Trap
Numbers
Array
Manager
Event
Number
Vue de la page 66