Server Administrator GUI and CLI Response Time
On Dell PowerEdge x8xx and later systems, the response time for some parts of the Dell
OpenManage Server Administrator GUI and CLI have increased to several seconds because some of
the iDRAC data is no longer cached by Server Administrator. The data must be retrieved from the
iDRAC when requested by you.
The Server Administrator GUI pages whose response time may have increased are as follows:
Server Administrator home page on log in
Remote Access -> Users
Alert Management -> Platform Events
The Server Administrator CLI commands whose response time may have increased are as follows:
omreport chassis remoteaccess config=user
omreport system platformevents
omreport system pedestinations
The amount of time varies depending on the hardware system and operating system.
Notes for Instrumentation Service
When configuring BIOS setup options through server administrator, if conflict BIOS settings exist, the
update attempt may fail at system reboot and possibly none of the BIOS setup option is updated.
For example, when you configure Embedded SATA Controller to RAID and Boot Mode to UEFI
simultaneously (UEFI does not support RAID option), this conflict prevents any BIOS configuration
to be updated (at system reboot).
On certain systems, user-defined thresholds set under Server Administrator become the default thresholds
after uninstalling Server Administrator.
After you change the threshold value of a probe on certain systems running Server Administrator
and then uninstall Server Administrator, the changed threshold value becomes the default threshold
value.
When modifying the warning threshold settings, the values are stored in the firmware as discrete integer
values and scaled for display. If the modified value is not a discrete integer, it may change when saved.
Fan redundancy can have the following states:
Fully Redundant: The sensors display this status if all the fans in the system are present and are in a
non-failure state.
OR
Redundancy Lost: The sensors display this status whenever any system fan fails or is removed from
the chassis.
If a system with memory redundancy enabled enters a "redundancy lost" state, it may not be apparent which
memory module is the cause. If you cannot determine which DIMM to replace, see the "switch to spare
memory detected" log entry in the ESM system log to find the memory module that failed.
If you run Server Administrator while the system is in "OS Install Mode", memory may be reported
incorrectly by Server Administrator.
To avoid this issue, you must disable "OS Install Mode" before running Server Administrator.
If you have to uninstall and reinstall the operating system SNMP service, then reinstall Server Administrator
as well, so that the Server Administrator SNMP agents are registered with the operating system SNMP agent.
Server Administrator Device Drivers for Linux
Server Administrator includes two device drivers for Linux: Dell Systems Management Base Driver
(dcdbas) and Dell BIOS Update Driver (dell_rbu). Server Administrator uses these drivers to
perform its systems management functions. Depending on the system, Server Administrator loads
one or both of these drivers if required. These drivers have been released as open source under the
GNU General Public License v2.0. They are available in Linux kernels from kernel.org starting with
kernel 2.6.14.
Notes for Storage Management Service
Vue de la page 3
1 2 3 4 5 6 7 8 9 ... 14 15

Commentaires sur ces manuels

Pas de commentaire

Electrolux Air-O-Convect AOS102GCD1 manuals

Owner’s manuals and user’s guides for Convection ovens Electrolux Air-O-Convect AOS102GCD1.
We providing 1 pdf manuals Electrolux Air-O-Convect AOS102GCD1 for download free by document types: User Manual






More products and manuals for Convection ovens Electrolux

Models Document Type
922090 User Manual   Electrolux 922090 User Manual, 16 pages
269092 User Manual     Electrolux 269092 User Manual, 38 pages
Air-O-Convect AOS62ECB1 User Manual   Electrolux Air-O-Convect AOS62ECB1 User Manual, 2 pages
269085 User Manual    Electrolux 269085 User Manual, 30 pages
Air-O-Convect AOS102ECA1 User Manual   Electrolux Air-O-Convect AOS102ECA1 User Manual, 4 pages
Convection Microwave Oven PN316902496 User Manual   Electrolux Convection Microwave Oven PN316902496 User Manual, 39 pages
260727 User Manual   Electrolux 260727 User Manual [en] , 2 pages
LPG Gas Hybrid Convection Oven 201 User Manual   Electrolux LPG Gas Hybrid Convection Oven 201 User Manual, 3 pages
Air-O-Convect AOS201ECA1 User Manual   Electrolux Air-O-Convect AOS201ECA1 User Manual, 4 pages
269552 User Manual   Electrolux 269552 User Manual, 32 pages
Convection Oven 81 User Manual   Electrolux Convection Oven 81 User Manual, 3 pages
Air-O-Convect 269504 User Manual   Electrolux Air-O-Convect 269504 User Manual [en] , 4 pages
Air-O-Steam AOS201EAM1 User Manual   Electrolux Air-O-Steam AOS201EAM1 User Manual, 2 pages
Air-O-Convect 269012 User Manual   Electrolux Air-O-Convect 269012 User Manual, 4 pages
Zanussi Professional FCFE043 User Manual   Electrolux Zanussi Professional FCFE043 User Manual, 2 pages
air-o-convect Natrural Gas Hybrid Convection Oven User Manual   Electrolux air-o-convect Natrural Gas Hybrid Convection Oven 102 User Manual, 2 pages
FCG061 User Manual   Electrolux FCG061 User Manual, 2 pages
Air-O-Convect 269000 User Manual   Electrolux Air-O-Convect 269000 User Manual, 4 pages
LW 20 GN User Manual   Electrolux LW 20 GN User Manual, 4 pages
260462 User Manual   Electrolux 260462 User Manual, 32 pages