564 Storage Management Group
Array Disk Smart Alert Indication
Array Disk Manufacture Day
Array Disk Manufacture Week
Name arrayDiskSmartAlertIndication
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31
Description Indicates whether the disk has received a predictive failure.
Possible values:
1: No - disk has not received a predictive failure alert
2: Yes - disk has received a predictive failure alert
Syntax Integer
Access Read-only
Name arrayDiskManufactureDay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.32
Description Indicates the day of the week (1=Sunday through 7=Saturday) on
which this disk was manufactured.
Syntax DisplayString
Access Read-only
Name arrayDiskManufactureWeek
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.33
Description The week (1 through 53) in which this disk was manufactured.
Syntax DisplayString
Access Read-only