Vue de la page 662
Dell RAC Out-of-Band Group 663
DRsCMC PSUTableEntry
CMC Power Information
The following MIB tables provide information on the chassis power.
DRsChassisIndex
DRsPotentialPower
Name DrsCMCPSUTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1
Description Defines the CMC PSU table entry.
Syntax DrsCMCPSUTableEntry
Access Not-accessible
Name DrsChassisIndex
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1
Description Defines the index (one-based) of the associated chassis.
Syntax DellCMCPowerIndexRange
Access Read-only
Name DRsPotentialPower
Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2
Description Defines the power (in Watts) required by the chassis infrastructure,
plus the sum of the maximum power requirements for all systems
currently turned on.
Syntax DellPowerReading
Access Read-only