Dell OpenManage Server AdministratorVersion 7.3 Command Line Interface Guide
name=value pair 1 name=value pair 2 DescriptionAdministrator Web server environment.attribute=signalgorithm algorithm=MD5 | SHA1 | SHA256 | SHA512MD5:
The event is a power supply failure and the action is to broadcast a message to all Server Administrator users.Available Alert ActionsThe following ta
Event Name Descriptionevent=systempowerfail Sets actions when a power consumption probe detects a failure value.event=powersupply Sets actions when a
Event Name DescriptionNOTE: This event is not available on blade systems.Example Set Alert Action CommandsThe following are examples of valid example
To clear the contents of the command log, type:omconfig system cmdlog action=clearoromconfig servermodule cmdlog action=clearTo clear the contents of
NOTE: Alert settings are mutually exclusive and you can set one at a time only. The action settings are also mutually exclusive and you can set one at
Event Name Descriptionevent=powerwarn Sets action or enables or disables alert generation when a power device probe detects that the power supply, vol
Event Name Descriptionevent=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD card is
name=value pair Descriptiontype=systempower Configures events for system power.type=temps Configures events for temperatures.type=volts Configures eve
oromconfig servermodule events type=fan index=0 severity=criticalAs a result of the example command, Server Administrator sends an SNMP trap only when
1IntroductionDell OpenManage Server Administrator (OMSA) provides a comprehensive, one-to-one systems management solution through either an integrated
oromconfig servermodule recovery timer=120Omconfig System Shutdown Or Omconfig Servermodule ShutdownUse the omconfig system shutdown or omconfig serve
Table 51. Valid Parameters Of Thermal Shutdownname=value pair Descriptionseverity=disabled | warning | failuredisabled: Disable thermal shutdown. An a
112
5Omconfig System Or Servermodule Assetinfo: Editing Cost Of Ownership ValuesThe omconfig system assetinfo or omconfig servermodule assetinfo command h
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptiondevelopment or sales.installdate=<mmddyy> Date the
oromconfig servermodule assetinfo info=acquisition purchasecost=5000 waybill=123456 installdate=120501 purchasedate=050601 ponum=9999 signauth="J
Adding Extended Warranty InformationUse the omconfig system extwarranty or omconfig servermodule extwarranty command to assign values for extended war
Table 56. Valid Parameters Of omconfig system assetinfo info=lease Or omconfig servermodule assetinfo info=leaseCommand Level 1Command Level 2 Command
Table 57. Valid Parameters Of omconfig system assetinfo info=maintenance Or omconfig servermodule assetinfo info=maintenanceCommand Level 1Command Lev
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionproviderfee=<providerfee> Amount of money charged f
– Upgraded to JRE version 1.7 Update 21– Upgraded to Apache Tomcat version 7.0.39• Added support for Google Chrome 21 and 22• Added support for Safari
Example Command For Adding Owner InformationTo provide a value for an owner parameter, type a command of the form omconfig system assetinfo info=owner
Adding Support InformationSupport refers to technical assistance that the system user can seek when the user seeks guidance on the proper use of a sys
Adding System InformationSystem information includes the primary user of the system, the phone number for the primary user, and the location of the sy
Command Level 1Command Level 2Command Level 3Name= Value Pair 1Name= Value Pair 2 Descriptionenddate=<enddate> Date the warranty agreement ends.
124
6Using The Storage Management ServiceThe CLI of Storage Management enables you to perform reporting, configuration, and management functions of Storag
In this example, the id in controller=idis the controller number such that controller 1 is specified as controller=1.Syntax Of Command ElementsThe omr
Syntax DescriptionFor example, when creating a virtual disk, the [name=<string>] parameter indicates that you have the option of specifying the
128
7Omreport Storage CommandsThe omreport command allows you to view storage component information for disks, controllers, enclosures, batteries, global
occurs. You can also use the omconfig command to assign specific values to the system's asset information parameters, such as the purchase price
Command Level 1Command Level 2Command Level 3Usefluidcachepool Displays fluid cache pool properties.partition Displays the partition details of the sp
Table 68. omreport Virtual Disk CommandsRequired Command Levels (1, 2, 3) Optional name=value pairs Useomreport storage vdisk Displays property inform
Required Command Levels (1, 2, 3)Optional name=value pairs UseExample for SCSI controllers: controller=0 enclosure=2. Example for SAS controllers: con
Required Command Levels (1, 2, 3) and name=value pairOptional name=value pairs Usenumber. For example: controller=0 enclosure=2NOTE: For SCSI controll
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.Table 74. Omreport EMM CommandsRequired Command
Table 76. Omreport Battery CommandsRequired Command Levels (1, 2, 3) Optional name=value pairs Useomreport storage battery Displays all batteries pres
Required Command Levels (1, 2, 3) Optional name=value pairs UseNOTE: When the connectors are connected to the enclosure in redundant path mode, the Na
Table 82. omreport Fluid Cache Pool CommandRequired Command Levels (1, 2, 3) And name=value pair Useomreport storage fluidcachepoolDisplays the proper
8Omconfig Storage CommandsThe omconfig commands allows you to configure physical disks, virtual disks, controllers, enclosures, batteries, global info
The following are examples of some failure messages:Commandomconfig chassis volts index=3 minwarnthresh=3.3000MessageError! Number with up to 3 digits
Omconfig Physical Disk CommandsThe following sections provide the omconfig command syntax required to execute physical disk tasksTable 87. Omconfig Ph
Example for SCSI, SATA, and ATA controllersomconfig storage pdisk action=blink controller=1 pdisk=0:0Example for SAS controllers omconfig storage pdis
Omconfig Instant Erase Secured Physical DiskDescriptionErases the given encrypted disk.Syntaxomconfig storage pdisk action=instantsecureerase controll
Example for SCSI, SATA, and ATA controllersomconfig storage pdisk action=offline controller=1 pdisk=0:3Example for SAS controllers omconfig storage pd
Omconfig Rebuild Physical DiskDescription Rebuilds a failed physical disk. Rebuilding a disk may take several hours. If you need to cancel the rebuild
Omconfig Cancel Replace MemberDescriptionCancels a replace member operation.Syntaxomconfig storage pdisk action=cancelreplacemember controller=id pdis
Example to Cancel the clear of physical disk 3 on connector 0 of controller 1. On a SAS controller, the physical disk resides in enclosure 2.Example
Omconfig Export Reliability LogDescriptionExports log on a physical disk or the PCIe SSD controller.Syntaxomconfig storage pdisk action=exportreliabil
controller=id pdisk=<PDISKID>, where id is the controller ID. The <PDISKID> variable specifies the physical disk.NOTE: To obtain these val
Required Command Levels (1, 2, 3)Optional name=value pairsaction=format controller=id vdisk=idaction=reconfigure controller=id vdisk=id raid=<c | r
The next level of complexity includes commands that contain command levels 1 and 2. All of the about commands are examples of command level 2 complexi
Example omconfig storage vdisk action=cancelcheckconsistency controller=1 vdisk=4 Omconfig Pause Check ConsistencyDescriptionPauses a check consistenc
Omconfig Unblink Virtual DiskDescriptionUnblinks the physical disks included in a virtual disk.Syntax omconfig storage vdisk action=unblink controller
Omconfig Slow Initialize Virtualize DiskDescription Slow initializes a virtual disk.CAUTION: You may receive a warning message if you attempt to delet
Example omconfig storage vdisk action=cancelbginitialize controller=1 vdisk=4Omconfig Assign Dedicated Hot SpareDescription Assigns one or more physic
Omconfig Format Virtual DiskDescription Formats a virtual disk.Syntax omconfig storage vdisk action=format controller=id vdisk=id, where id is the con
NOTE: To obtain these values, type omreport storage controller to display the controller IDs and then type omreport storage vdisk controller=ID to dis
Omconfig Replace Member Virtual DiskDescription Replaces the member of a given virtual disk with the destination disk.Syntaxomconfig storage vdisk act
Omconfig Disable Fluid Cache on Virtual DiskDescription Disables fluid cache for the specified virtual disk.Syntaxomconfig storage vdisk action=disabl
Required Command Levels (1, 2, 3)Optional name=value pairs16kb | 32kb | 64kb | 128kb | 256kb | 512kb | 1mb >] [cachepolicy=<d | c>] [readpoli
Required Command Levels (1, 2, 3)Optional name=value pairsaction=startpatrolread controller=idaction=stoppatrolread controller=idaction=createcachecad
16
Example omconfig storage controller action=disablealarm controller=1Omconfig Quiet Controller AlarmTable 91. omconfig Quiet Controller AlarmDescriptio
The omconfig syntax for creating a virtual disk has several parameters. You must specify the following parameters:• Controller (controller=id)• RAID l
Parameters Typesize=<number | max | min> Requiredpdisk=<connector:targetID,connector:targetID,...> Required[stripesize=<2k b| 4kb | 8
size=<number | max | min> Parameter Specification Description(megabytes), or g (gigabytes). For example, size=500m indicates that the virtual di
Table 98. Read Policy ParametersRead Policy readpolicy=ra | ara | nra | rc | nrc Parameter SpecificationRead ahead readpolicy=raAdaptive read ahead re
RAID Level or Concatenation raid=n Parameter SpecificationConcatenation raid=csize=<number | max | min> ParameterThe following table displays ho
Diskcachepolicy=<disabled | enabled>Different controllers support different disk cache policies. The following table indicates how to specify th
For RAID 10 on SAS controllers with firmware version 6.1 and later, spanlength is optional. Also, you can now specify the spanlength as an even number
If you set force=enabled, the cache is discarded irrespective of whether the controller detects a foreign or an offline virtual disk.Example to Disca
Omconfig Set Background Initialization RateDescription Sets the background initialization rate.Syntaxomconfig storage controller action=setbgirate con
2Using The omhelp CommandThe omhelp command and its equivalent, <command> -?, accesses the detailed help-text interface of Command Line Interfac
Omconfig Import Secure Foreign ConfigurationDescription Unlocks the encrypted Local Key Management (LKM) foreign configuration drives.Syntaxomconfig s
Omconfig Physical Disk Power ManagementDescription Manages the power of physical disks in a controller by spinning down hot spares, configured drives,
Example to Stop the patrol read task on controller 1.Exampleomconfig storage controller action=stoppatrolread controller=1NOTE: To stop patrol read,
Example to Convert multiple non-RAID to RAID on controller 0.Example omconfig storage controller action=convertnonraidtoraid controller=0 pdisk=0:2:3O
Omconfig Disable Enclosure AlarmTable 108. Omconfig Disable Enclosure AlarmDescription Disables the enclosure alarm.Syntaxomconfig storage enclosure a
Omconfig Set Temperature Probe ThresholdsTable 111. Omconfig Set Temperature Probe ThresholdsDescription Sets the minimum and maximum warning temperat
NOTE: This command is not supported on SCSI RAID controllers.Syntaxomconfig storage enclosure action=setalltempprobes controller=id enclosure=<ENCL
Table 116. Omconfig Battery CommandsRequired Command Levels (1, 2, 3)Optional name=value pairsomconfig storage battery action=startlearn controller=id
Required Command Levels (1, 2, 3)Optional name=value pairsaction=globalrescanaction=setprotectionpolicies type=ghs or dhsOmconfig Global Enable Smart
Example to Do a global rescan of all controllers. The omconfig command syntax for rescanning all controllers on the system does not require a controll
When you type omconfig system assetinfo -?, the help that displays provides information about assigning values for the name and option fields. Partial
Omconfig Cachecade CommandsThe following table displays the omconfig command syntax required to execute cachecade tasks.Table 122. omconfig Cachecade
storage cachecade controller=ID to display the IDs for the cachecades of the controller.In some circumstances, you may receive a warning message. You
Table 123. omconfig PCIe SSD CommandsRequired Command Levels (1, 2, 3)Optional name=value pairsomconfig storage pciessdaction=addtocachepool subsystem
Omconfig Fluid Cache CommandsThe following sections provide the omconfig command syntax required to execute fluid cache tasks.Table 124. Omconfig Flui
Omconfig Fluid Cache Disk CommandThe following section provide the omconfig command syntax required to execute the fluid cache disk task.Table 126. Om
9Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use the command output in various ways. This chapter expl
Writing Command Output To A FileWhen redirecting command results to a file, you can specify a filename (and a directory path if necessary) to which yo
Minimum Failure Threshold : 500RPMMaximum Failure Threshold : 6000RPMYou cannot refer to the previous command results to compare the earlier fan probe
Maximum Failure Threshold: 6000RPMYou can use a text editor to insert the time that each block of data was captured. In comparing the two snapshots fo
--------------Network Interface 0 IP Address : 143.166.152.108Subnet Mask : 255.255.255.0Default Gateway : 143.166.152.1MAC Address : 00-0
3omreport: Viewing System Status Using The Instrumentation ServiceThe omreport command allows you to see detailed information about the system compone
You can also set preferences for the custom delimited format with the omconfig command. The valid values for delimiters are: exclamation, semicolon, a
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
NOTE: When a system includes an external chassis, the displayed results vary by operating system. On SUSE Linux Enterprise Server and Red Hat Enterpri
Command Level 1Command Level 2 Command Level 3User Privilege RequiredUsehwperformance U, P, A Displays the status and cause for the system’s performan
Command Level 1Command Level 2 Command Level 3User Privilege RequiredUsealertaction U, P, A Displays the warning and failure threshold values, as well
Use omreport <command level 2> -? to get help on the level 2 about, chassis, and system commands. The following information on omreport system -
Attribute : Remote Connect InterfaceValue : Launch CMC Web Interface omreport aboutUse the omreport about command to learn the product name and vers
Ok : MemoryOk : Power SuppliesOk : TemperaturesOk : Voltages Omreport Chassis Acswitch Or Omreport Mainsystem AcswitchUse the omreport
Omreport Chassis Batteries Or Omreport Mainsystem BatteriesUse the omreport chassis batteries or omreport mainsystem batteries command to view battery
Table 5. BIOS Setup Parameters On Systems Prior To Dell PowerEdge 12G SystemsParameter DescriptionBootsequence Displays the device used to boot the sy
Parameter DescriptionHT Assist Displays the status of the probe filter chipset option.Internal SD Card Displays whether the internal SD card is enable
Parameter DescriptionConsole Redirection After Boot Displays whether console redirection after system reboot is enabled or disabled.External Serial Co
Contents1 Introduction...
Omreport Chassis Fans Or Omreport Mainsystem FansUse the omreport chassis fans or omreport mainsystem fans command to view the fan probe status and se
Server Administrator displays a summary of the system’s FRU information. This information is available in the Server Administrator GUI, SNMP, and Comm
Express Service Code : 15608862073Chassis Asset Tag : cOmreport Chassis IntrusionUse the omreport chassis intrusion command to find out whether the
The index parameter is optional. If you do not specify the index, Server Administrator displays information for all memory modules on the system as fo
Connector Name : DIMM_A3Type : DDR3 - Synchronous Registered (Buffered)Size : 8192 MBIndex : 3Status : OkConnector Name : DIMM_A4Type : DDR3 -
The index parameter is optional. If you do not specify the index, Server Administrator displays properties of all NICs on the system and the values fo
Field Descriptionconnect a different device type to a system. Examples include DB-9 Male, AT, Access Bus, PS/2, and so on.Maximum SpeedPort speed. Por
Microprocessor Fields• Execute Disable (XD)• Turbo ModeAMD Processor• 64-bit Support• AMD-V• AMD PowerNow!• No Execute (NX)The following fields are de
Field DescriptionIn a write-through policy, the processor writes through the cache to the main memory. The write cycle does not complete until the dat
For each power management profile in the system, values display for the following fields: Maximum Performance, Active Power Controller, OS Control, an
Omreport Chassis Processors Or Omreport Mainsystem Processors...36Omreport Chassis Pwrmanage
• System Peak AmperageNOTE: The omreport chassis pwrmonitoring or omreport mainsystem pwrmonitoring command is applicable from PowerEdge 10G system on
NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, non
name=value pair Descriptionconfig=serialoverlan Reports BMC/iDRAC or remote access information on a serial over LAN connection.config=terminalmode Rep
Omreport Chassis Slots Or Omreport Mainsystem SlotsUse the omreport chassis slots or omreport mainsystem slots command to view properties of the syste
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of status, readings, and thresholds set for
SEVERITY : COMPONENTOk : Main System ChassisCritical : StorageCommands For Viewing LogsUse the omreport system or omreport servermo
The omreport system alertaction or omreport servermodule alertaction command is useful for viewing which alert actions have been specified for compone
• Virtual Disk Warning• Virtual Disk Failure• Enclosure Warning• Enclosure Failure• Storage Controller Battery Warning• Storage Controller Battery Fai
Removable Flash Media---------------------SettingsEnable: Informational, Warning and CriticalDisable: NoneThe full report lists the settings for all c
Fans Group----------SettingsEnable: Informational, Warning, and CriticalDisable: None-----------Individual Objects-----------System Board Fan1 RPM Set
Omconfig Chassis Pwrmanagement Or Omconfig Mainsystem Pwrmanagement...85Omconfig Chassis Pwrmonitoring Or Omcon
Output Attributes Description110.120.130.140: IPv4 address of the second destination.Destination Number: Destination 3destination 3: Displays the thir
Omreport System Shutdown Or Omreport Servermodule ShutdownUse the omreport system shutdown or omreport servermodule shutdown command to view any pendi
: Server Administrator Core files 7.x.x: Storage Management 4.x.x: Sun Java Runtime Environment 1.x.xOperating System Name : Microsoft Windows Server
Total Maximum Capacity :786432 MBMemory Array Count : 1Memory Array 1 Location : System Board or Motherboard Use : System MemoryInstalled Capacity
Default Gateway : 10.94.22.1 MAC Address : 14-FE-B5-FF-AF-D0Network Interface 1 IP Address : [No Value]MAC Address : 14-FE-B5-FF-AF-D1Network Inte
• Maximum Speed• External Clock Speed• VoltageMemory• Total Installed Capacity• Memory Available to the Operating System• Total Maximum Capacity• Memo
The three properties that display for thermal shutdown are disabled, warning, or failure. If the CLI displays the following message, the thermal shutd
Omreport Preferences MessagesUse the omreport preferences messages to view the configured alert message format.The following table lists the available
4Omconfig: Managing Components Using The Instrumentation ServiceThe omconfig command allows you to provide values that define warning events, configur
Adding System Information...
privilege you need to run the command, where U = User, P = Power User, and A = Administrator. Use is a very general statement about the actions that a
Command Level 1Command Level 2Command Level 3User Privilege RequiredUsepedestinations P, A Sets IP addresses for alert destinations.platformevents A D
Command Level 1Command Level 2Command Level 3User Privilege RequiredUseNOTE: You cannot change threshold values on ESM3 and PowerEdge x8xx systems.vol
Omconfig AboutUse the omconfig about command to learn the product name and version number of the systems management application installed on the syste
• Enable or disable power button control features if the system configuration permitsUse the omconfig chassis -? or omconfig mainsystem -? command to
name=value pair 1 attribute= name=value pair 2 setting= DescriptionNOTE: On Linux systems, user or user groups upgraded to administrator or administra
name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=crab setting=enabled | disabled• enabled: Enables BIOS console redirectio
name=value pair 1 attribute= name=value pair 2 setting= Description• disable: Disables DBS on the system.attribute=diskette setting=off | auto | write
name=value pair 1 attribute= name=value pair 2 setting= Description• disabled: Disables the embedded hypervisor.attribute=embvideoctrl setting=enabled
name=value pair 1 attribute= name=value pair 2 setting= Description• auto: Detects and enables the device automatically.attribute=intrusion setting=en
Omconfig Cancel Rebuild Physical Disk... 144Omcon
name=value pair 1 attribute= name=value pair 2 setting= Description• enablednonepxe: Enables the second NIC during system boot (with PXE off if the sy
name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=NodeInterleaveNOTE: Use NodeInterleave instead of numa as numa will be de
name=value pair 1 attribute= name=value pair 2 setting= Descriptionattribute=romba setting=raid | scsi force=true• raid: Instructs the BIOS to detect
name=value pair 1 attribute= name=value pair 2 setting= Descriptionconsole redirection through COM1.• com2: Enables serial communication setting with
name=value pair 1 attribute= name=value pair 2 setting= Description• enabled: Enables CPU Turbo Mode.• disabled: Disables CPU Turbo Mode.attribute=uau
Table 22. BIOS Setup Settings On PowerEdge 12G SystemsGroup name=value pair 1 attribute= name=value pair 2 setting=BIOS Boot Settings attribute=BootSe
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=SysMemVolt setting=<string>attribute=VideoMem setting=<string>Misce
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=Proc3NumCores setting=<integer>attribute=Proc4Brand setting=<string>
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=SataPortCDriveType setting=<string>attribute=SataPortCModel setting=<s
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=Slot4 setting=Enabled | Disabled | BootDriverDisabledattribute=Slot5 setting=En
omconfig Change Controller Properties...167Omcon
Group name=value pair 1 attribute= name=value pair 2 setting=attribute=TcmActivation setting=NoChange | Activate | Deactivateattribute=TcmClearCAUTION
oromconfig mainsystem fans index=0 warnthresh=defaultYou cannot default one value and set another. In other words, if you default the minimum warning
Table 24. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanelname=value pair 1 name=value pair 2 Descriptionlcdindex=<
Table 25. Valid Parameters Of Omconfig Chassis Info Or Omconfig Mainsystem Infoname=value pair Descriptionindex=<n> Number of the chassis whose
name=value pair 1 name=value pair 2 Descriptionled=identify flash=off | on time-out=<n> Sets the chassis identification LED to off or on. Set th
name=value pair 1 Descriptionexpense of some memory capacity. The RAID mode supported is RAID level 5 striping with rotational parity.dddc: The dddc m
name=value pair 1 name=value pair 2 DescriptionNOTE: This option is supported on systems prior to PowerEdge 12G systems.apc: Active Power Control (apc
Table 29. Valid Parameters Of Omconfig Chassis Pwrmonitoring Or Omconfig Mainsystem Pwrmonitoringname=value pair 1 name=value pair 2 Descriptionindex=
• Remote access on a local area network (LAN).• The serial port for BMC or RAC, whichever is installed.• The BMC or RAC on a serial over LAN connectio
name=value pair 1 config=name=value pair 2 Descriptionteamednic1nic2: Enables NIC teaming functionality.dracnic: Enables DRAC NIC if DRAC 5 is install
Omconfig Cachecade Commands... 18
name=value pair 1 config=name=value pair 2 Descriptiongateway=GatewaySets a gateway address if you have selected static as the IP address source for t
name=value pair 1 config=name=value pair 2 DescriptionNOTE: Baud rates of 9600 and 19200 are supported on PowerEdge 1800, 1850, 2800, and 2850 systems
name=value pair 1 config=name=value pair 2 DescriptionNOTE: Baud rates of 9600 and 19200 are supported on PowerEdge 1800, 1850, 2800, and 2850 systems
name=value pair 1 config=name=value pair 2 Descriptionlfcr: BMC uses <LF-CR> as a new line sequence when the BMC writes a new line to the consol
name=value pair 1 config=name=value pair 2 Descriptiondracusergroup=poweruser: Enables the Power User privileges.dracusergroup=guest: Enables the Gues
name=value pair 1name=value pair 2 name=value pair 3 Descriptionaccessvirtualmedia=true | false true or false: Enables or disables access to virtual m
You cannot default one value and set another. In other words, if you set the minimum warning threshold value to the default value, you are also select
Omconfig PreferencesUse the omconfig preferences command to set system preferences. Use the command line to set the SNMP root password and specify the
Table 36. Valid Parameters Of Configuring Preferences Messagesname=value pair 1 name=value pair 2 Descriptionattribute=format setting=traditional | en
Table 38. SNMP Set Operations Parametersname=value pair Descriptionsetting=snmpset Requiredenable=true Allows SNMP set operationsenable=false Disallow