Dell OpenManage Server Administrator Version 6.5 Guide de l'utilisateur Page 215

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 776
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 214
Thermal Group 217
Temperature Probe Upper Noncritical Threshold
Temperature Probe Lower Noncritical Threshold
Temperature Probe Lower Critical Threshold
Temperature Probe Lower Nonrecoverable Threshold
Name temperatureProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11
Description Defines the user-assigned value of the temperature probe’s
upper noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name temperatureProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12
Description Defines the user-assigned value of the temperature probe’s
lower noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name temperatureProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.13
Description Defines the value of the temperature probe’s lower critical threshold.
Syntax DellSigned32BitRange
Access Read-only
Name temperatureProbeLowerNonRecoverableThreshold
Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14
Description Defines the value of the temperature probe’s lower
nonrecoverable threshold.
Syntax DellSigned32BitRange
Access Read-only
book.book Page 217 Monday, March 14, 2011 3:01 PM
Vue de la page 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 775 776

Commentaires sur ces manuels

Pas de commentaire