Vue de la page 649
652 Storage Management Group
Battery Predicted Capacity
Battery Next Learn Time
Name batteryPredictedCapacity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be
replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge
capacity of the battery cannot be determined until the Learn cycle
is complete.
Syntax Integer
Access Read-only
Name batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be
executed
Syntax Integer
Access Read-only
book.book Page 652 Monday, March 14, 2011 3:01 PM