Dell PowerEdge C5220 Comment utiliser Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
55
NOTE: Support for Partial Add SEL is not required when Add SEL is supported.
Get POH Counter Chassis 0Fh O Yes
[1] Optional portion of Get System Reset Cause is not support.
Table 1-43. Event Commands
Command NetFn CMD O/M Supported
Even
Receiver
Event
Generator
Set Event Receiver S/E 00h M M Yes
Get Event Receiver S/E 01h M M Yes
Platform Event S/E 02h M M Yes
Table 1-44. SEL Commands
Command NetFn CMD O/M Supported
Get SEL Info Storage 40h M Yes
Get SEL Allocation Info Storage 41h O Yes
Reserve SEL Storage 42h O Yes
Get SEL Entry Storage 43h M Yes
Add SEL Entry Storage 44h M Yes
Partial Add SEL Entry Storage 45h M Yes
Delete SEL Entry Storage 46h O Yes
Clear SEL Storage 47h M Yes
Get SEL Time Storage 48h M Yes
Set SEL Time Storage 49h M Yes
Get Auxiliary Log Status Storage 5Ah O No
Set Auxiliary Log Status Storage 5Bh O No
Table 1-42. Chassis Commands
Command NetFn CMD O/M Supported