Error Code Message Information
PSU0006
Message Power supply <
number
> type mismatch.
LCD Message Power supply <
number
> is incorrectly configured. Check PSU.
Details Power supplies should be of the same input type and power rating.
Action Install matched power supplies and review proper configuration in
this manual.
PSU0016
Message Power supply <
number
> is absent.
LCD Message PSU <
number
> is absent. Check PSU.
Details The power supply has been removed or has failed.
Action
1. Remove and reinstall the power supply.
2. Check cables and subsystem components in the system for
damage.
3. If the issue persists, see Getting Help.
PSU0031
Message Cannot communicate with power supply <
number
>.
LCD Message Cannot communicate with PSU <
number
>. Re-seat PSU.
Details The power supply may operate, however power supply monitoring is
degraded. System performance may be degraded.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
PSU0032
Message The temperature for power supply <
number
> is in a warning range.
Details System performance may be degraded.
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.
PSU0033
Message The temperature for power supply <
number
> is outside of the
allowable range.
LCD Message PSU <
number
> temperature outside of range. Check PSU.
Details System performance may be degraded.
Action Check the system operating environment, including airflow and inlet
temperature. Check system logs for temperature and thermal
component failures.