Vue de la page 110
Chassis Information Group 113
NOTE: Chassis identification capabilities allow system administrators to set front
panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning
components. When enabled, the blinking lights help administrators locate the
problem chassis.
Table 5-10. Chassis Identification Control Settings
Variable Name:
DellChassisIdentifyControlSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The chassis identification control’s state is
unknown.
enabled(2) The chassis identification control’s state is
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4)
The chassis identification control’s state
is not ready.
identifyChassis(8)
The chassis identification control’s
LEDs may be returned to (normal) 0,
or (identify chassis) 1.
identifyChassisAndEnable
(10)
The chassis identification control’s
LEDs may be returned to normal
(a binary 0 value), or identify chassis
and enabled (a binary 1 value).
Table 5-9. Chassis Identification Control Capabilities
(continued)
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
book.book Page 113 Wednesday, March 6, 2013 12:37 AM