Battery Next Learn Time
Battery Learn State
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be
replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge
capacity of the battery cannot be determined until the Learn cycle
is complete.
Syntax Integer
Access Read-only
Name batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be
executed.
Syntax Integer
Access Read-only
Name batteryLearnState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12
Description Specifies the learn state activity of the battery.
Possible values:
1: Failed
2: Active
4: Timed out
8: Requested
16: Idle
32: Due
Name batteryPredictedCapacity