iDRAC7 MIB 805
Table 28-15. Power Supply Absent Trap
Table 28-16. Power Usage Traps
Table 28-17. Redundancy Traps
TrapID Description Category SubCategory Severity
Power Supply Absent
2465 Power supply is absent. System
Health
PSU Absent Critical
TrapID Description Category SubCategory Severity
Power Usage Information
2275 System performance
restored.
System
Health
Power Usage Informational
Power Usage Warning
2274 System performance
degraded.
System
Health
Power Usage Minor
Power Usage Failure
2273 The system halted
because system power
exceeds capacity; or the
system performance
degraded because power
draw exceeds the power
threshold.
System
Health
Power Usage Critical
TrapID Description Category SubCategory Severity
Redundancy Information
2475 Redundancy
information.
System
Health
Redundancy Informational
Redundancy Degraded
2474 Redundancy is degraded. System
Health
Redundancy Minor
Redundancy Lost
2473 Redundancy is lost. System
Health
Redundancy Critical