PCI BIOS failed to install
PCI device (option ROM) checksum
failure is detected during shadowing.
Contact the PCI device manufacturer to obtain a suitable
replacement PCI option ROM. Follow the manufacturer's
instructions to install the option ROM.
Plug & Play Configuration Error
Error encountered when initializing the
PCI device, or the system board is
defective.
Install the NVRAM_CLR jumper and reboot the system. If the
problem persists, replace the system board. See "Getting
Help."
Plug & Play Configuration Error PCI_n
Error encountered when initializing the
PCI adapter.
Install the NVRAM_CLR jumper and reboot the system. If the
problem persists, replace the specified expansion-card. See
"Installing Expansion Cards" in "Installing System Options." If
the problem persists, replace the system board. See "Getting
Help."
Primary backplane error
Improperly attached or missing
backplane.
Ensure that the SCSI backplane board is fully seated. See
"Troubleshooting SCSI Hard Drives" in "Troubleshooting Your
System."
Primary IDE device 0 not found
Primary IDE device 1 not found
Improperly connected or missing IDE
device.
Ensure that the device's interface cable is securely connected
to the SCSI backplane board. Replace the device. If the
problem persists, see "Getting Help."
Processor 1 internal error
Processor 2 internal error
Defective microprocessor or system
board (reported by the NMI handler).
Replace the specified microprocessor. See "Installing
Microprocessors" in "Installing System Options." If the
problem persists, replace the system board. See "Getting
Help."
Processor bus error
PCI bus error
IMB bus error
Defective system board (reported by the
NMI handler).
Replace the system board. See "Getting Help."
Processor x is not a 533-MHz system bus
processor
This system bus speed is not supported on
this system board.
This system supports only Intel®
Xeon™533-MHz front-side-bus (system
bus) processors.
Reboot the system. If you receive beep code 4-4-3 (processor
frequency mismatch), replace processor x with a supported
processor. See "Installing Microprocessors" in "Installing
System Options."
If a beep code does not occur at system boot, turn off the
system, install the NVRAM_CLR jumper, and reboot the
system. If the message reappears, see "Getting Help."
Read fault
Requested sector not found
Faulty diskette, diskette-drive
subsystem, or hard-drive subsystem.
Replace the diskette, or reseat all drives and reboot the
system. If the message reappears, see "Getting Help."
Reset failed
Improperly connected diskette/tape
drive, hard drive, or power cable.
Check the drive and cable connections, and reset the system
again. If the message reappears, see "Getting Help."
ROM bad checksum = address
Expansion card improperly installed or
faulty.
Reinstall the expansion card. See "Installing Expansion
Cards" in "Installing System Options."
Sector not found
Seek error
Seek operation failed
Defective sectors on diskette or hard
drive.
Faulty diskette, diskette-drive
subsystem, or hard-drive subsystem.
Replace the diskette, or reseat all drives and reboot the
system. If the message reappears, see "Getting Help."
Shutdown failure
Defective system board.
Replace the system board. See "Getting Help."
System backplane error
Improperly attached or missing SCSI
backplane.
Check that the SCSI backplane board is fully seated. See
"Troubleshooting SCSI Hard Drives" in "Troubleshooting Your
System."
System halted! Must power down.
Wrong password entered too many
times.
Reboot the system and enter the correct password. If the
problem persists, see "Disabling a Forgotten Password" in
"Jumpers and Connectors."
System parity error
Defective expansion card(s) or
improperly seated or faulty memory
modules (reported by the NMI handler).
Replace the expansion cards one at a time until the error is
corrected. See "Installing Expansion Cards" in "Installing
System Options."
Remove and reseat the memory modules. See "Installing
Memory Modules" in "Installing System Options." If the
problem persists, replace the memory modules. If the problem
persists, see "Getting Help."
The following memory DIMMs are unsupported:
DIMM_xx.
This system only supports 266 MHz DIMMs.
One or more of the installed DIMMs has
a frequency less than 266 MHz. System
memorymustberatedfor266MHz.
Replace lower-speed DIMM(s) with modules rated for 266-
MHz operation. See "Installing Memory Modules" in "Installing
System Options."
Time-of-day clock stopped
Defective battery or faulty chip
(defective system board).
Replace the system battery. See "Replacing the System
Battery" in "Installing System Options." If the problem
persists, replace the system board. See "Getting Help."
Time-of-day not set - please run SETUP
program
Incorrect Time or Date settings or
defective system battery.
Check the Time and Date settings. See "Using the System
Setup Program" in the User's Guide. If the problem persists,
replace the system battery. See "Replacing the System
Battery" in "Installing System Options." If the problem
persists, replace the system board. See "Getting Help."
Timer chip counter 2 failed
Defective system board.
Replace the system board. See "Getting Help."
Unsupported CPU combination
Microprocessor combination is not
supported by the system.
Install a supported microprocessor combination. See
"Installing Microprocessors" in "Installing System Options."
Unsupported CPU stepping detected.
Microprocessor is not supported by the
system.
Install the correct version of the microprocessor in the
specified microprocessor socket. See "Installing
Microprocessors" in "Installing System Options."
Utility partition not available
<F10> key was pressed during POST,
Create a utility partition on the boot hard drive. See "Using