Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Guide de l'utilisateur Page 112

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 155
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 111
To use this object property for, you must have Chassis Configuration Administrator privileges.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
The following sections provide information about the objects in the cfgEmailAlert group.
cfgEmailAlertIndex (Read Only)
Description The unique index of an alert instance.
Legal Values 1-4
Default <
instance
>
cfgEmailAlertEnable (Read/Write)
Description Enables or disables the alert instance.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
cfgEmailAlertAddress (Read/Write)
Description Specifies the destination email address for email alerts,
for example, [email protected].
Legal Values E-mail address format, with a maximum length of 64 ASCII
characters.
Default <
blank
>
cfgEmailAlertEmailName
Description Specifies name or other identifier associated with the
destination e-mail address. The e-mail name can refer to
an individual, group, location, department, and so on.
Legal Values A string of up to 32 characters
Default <
blank
>
Example
racadm getconfig -g cfgEmailAlert -i 2
# cfgEmailAlertIndex=1
cfgEmailAlertEnable=1
cfgEmailAlertName=Kevin Fulton
112