NOTE: The server must be turned off to change the slot state. All servers must be
turned off to change the fabric state. The MAC/WWN addresses must be managed
locally (not by an external console) to use this command.
Synopsis
racadm setflexaddr [-i <slot#> <state>]
[-f <fabricName> <state>]
<
slot#
> = 1 to 4
<
fabricName
> = A
<
state
> = 0 or 1
where 0 is disable and 1 is enable.
Input
-i <
slot#
> <
state
> — Enables or disables FlexAddress for the specified slot.
-f <
fabricName
> <
state
> — Enables or disables FlexAddress for the specified
fabric.
Example
racadm setflexaddr -i 1 0
Slot 1 FlexAddress state set successfully
racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
racadm setflexaddr -f idrac 1
setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator
privilege on CMC. To enable the servers to blink or unblink, you must have the Server
Administrator or Debug Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input
-m <
module
> - Specifies the module whose LED you want to configure.
<
module
> can be one of the following:
— server-n, where
n
=1–4
— switch-n, where n=1
— cmc-active
— chassis
-l <
ledstate
> - Specifies whether the LED should blink.
<
ledstate
> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a
multi-slot server.