Storage Management Message Reference
2180 The controller
battery Learn
cycle will start
in %1 days.
OK / Normal /
Informational
Cause:
This alert is for
informational purposes.
The %1 indicates a
substitution variable.
The text for this
substitution variable is
displayed with the alert
in the alert log and can
vary depending on the
situation.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1151
2181 The controller
battery learn
cycle will start
in %1 hours.
OK / Normal /
Informational
Cause:
The %1
indicates a substitution
variable. The text for
this substitution
variable is displayed
with the alert in the
alert log and can vary
depending on the
situation. This alert is
for informational
purposes.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1151
2182 An invalid SAS
configuration
has been
detected.
Critical /
Failure / Error
Cause:
The controller
and attached enclosures
are not cabled correctly.
Action:
See the
hardware
documentation for
information on correct
cabling configurations.
Clear Alert:
None
Related Alert:
None
LRA Number:
2061
754
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert