Dell OpenManage Server Administrator Version 6.5 Guide de l'utilisateur Page 209

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 250
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 208
Storage Management Message Reference
209
2384 The Warning
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Warning /
Non-critical
Cause:
The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action:
Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1203
2385 The Critical
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
Critical /
Failure / Error
Cause:
The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action:
Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
1204
2386 The drive
could not be
assigned as a
Dedicated Hot
Spare.
Warning /
Non-critical
Cause:
The assignment
of a Dedicated Hot
Spare fails as the disk is
invalid.
Action:
None
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 249 250

Commentaires sur ces manuels

Pas de commentaire