Dell OpenManage Server Administrator Version 6.5 Guide de l'utilisateur Page 89

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 250
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 88
Storage Management Message Reference
89
2094 Predictive
Failure
reported.
Warning /
Non-critical
Cause:
The physical
disk is predicted to fail.
Many physical disks
contain Self Monitoring
Analysis and Reporting
Technology (SMART).
When enabled, SMART
monitors the health of
the disk based on
indications such as the
number of write
operations that have
been performed on the
disk.
Action:
Replace the
physical disk. Even
though the disk may
not have failed yet, it is
strongly recommended
that you replace the
disk.
If this disk is part of a
redundant virtual disk,
perform the
Offline
task on the disk; replace
the disk; and then
assign a hot spare and
the rebuild starts
automatically.
Clear Alert
Number:
None
Related Alert
Number:
None
LRA Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vue de la page 88
1 2 ... 84 85 86 87 88 89 90 91 92 93 94 ... 249 250

Commentaires sur ces manuels

Pas de commentaire