POST Error Codes
Code Log in BMC Error Message Corrective Action
0000 Yes Timer Error Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 123.
0003 Yes CMOS Battery Low See "Troubleshooting the System Battery"
on page 104.
0004 Yes CMOS Settings
Wrong
Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 123.
0005 Yes CMOS Checksum
Bad
Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 123.
000B Yes CMOS memory size
Wrong
Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 123.
000C Yes RAM R/W test failed Remove AC power to the system for
10 seconds and restart the system.
If the problem persists, see "Getting
Help" on page 123.
000E Yes A: Driver Error See "Troubleshooting a Hard Drive" on
page 109.
000F Yes B: Driver Error See "Troubleshooting a Hard Drive" on
page 109.
0012 Yes CMOS Date/Time
Not Set
Remove AC power to the system for
10 seconds and restart the system. See
"Troubleshooting the System Battery" on
page 104.
If the problem persists, see "Getting
Help" on page 123.