Dell PowerEdge M710 Manuel d'utilisateur Page 110

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 368
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 109
110 About Your System
E2012 Memory
configured
but unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
Blade Memory" on
page 319.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
Blade Memory" on
page 319.
E2014 CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E2015 DMA
Controller
failure.
Power cycle
AC.
DMA controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E2016 Interrupt
Controller
failure.
Power cycle
AC.
Interrupt controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
E2017 Timer refresh
failure.
Power cycle
AC.
Timer refresh failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 361.
Table 1-26. LCD Status Messages
(continued)
Code Text Cause Corrective Actions
Vue de la page 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 367 368

Commentaires sur ces manuels

Pas de commentaire