262 Device Group
Table 13-3. Processor Device Status Reading
Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
internalError(1) The processor experienced an internal error
thermalTrip(2) The processor experienced a thermal trip
configurationError(32) The processor experienced a configuration error
processorPresent(128) The processor is present
processorDisabled(256) The processor is disabled
terminatorPresent(512) The terminator is Present
processorThrottled(1024) The processor is throttled
Table 13-4. Processor Device Type
Variable Name: DellProcessorDeviceType
Data Type: Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1) The processor device type is not one of the
following values:
deviceTypeIsUnknown(2) The processor device type is unknown.
deviceTypeIsCPU(3) The processor device type is a central
processing unit.
deviceTypeIsMathProcessor(4) The processor device type is a math processor.
deviceTypeIsDSP(5) The processor device type is a digital
signal processor.
deviceTypeIsAVideoProcessor(6) The processor device is a video processor.