584 Traps
Memory Device Traps
Memory device messages provide status and warning information for memory modules present in a
particular system. Memory devices determine health status by counting the number of ECC memory
corrections.
NOTE: A value of failure or non-recoverable does not indicate a system failure or loss of data, but rather
that the specified system exceeded the specified ECC correction threshold. Although the system continues to
function, you should perform system maintenance as described in Table 25-10.
Power Supply Failure
1354 Power supply detected a failure
Sensor location: <
Location in
chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Power Supply type:
<type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type:
<type
of configuration error>
Error A power supply has been disconnected
or has failed. The sensor location,
chassis location, previous state, and
additional information about the power
supply event are provided.
Table 25-10. Memory Device Messages
Trap ID Description Severity Cause
1403 Memory device status is <
status
>
Memory device location:
<
Location in chassis
>
Possible memory module event
cause:
<list of causes>
Warning A memory device correction rate
exceeded an acceptable value. The
memory device status and location are
provided.
Table 25-9. Power Supply Traps (continued)
Trap ID Description Severity Cause