580 Traps
Amperage Probe Failure
1204 Current sensor detected a
failure value
Sensor location: <
Location in chassis
>
Chassis location: <
Name of chassis
>
Previous state was: <
State
>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state:
<State>
Error A current sensor on the power
supply for the specified system
exceeded its failure threshold. The
sensor location, chassis location,
previous state, and current sensor
value are provided.
Amperage Probe Nonrecoverable
1205 Current sensor detected a
non-recoverable value
Sensor location: <
Location in chassis
>
Chassis location: <
Name of chassis
>
Previous state was: <
State
>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state:
<State>
Error A current sensor in the specified
system detected an error from
which it cannot recover. The sensor
location, chassis location, previous
state, and current sensor value are
provided.
Table 25-6. Amperage Probe Traps (continued)
Trap ID Description Severity Cause