106 Storage Management Message Reference
2246 The controller
battery is
degraded.
Warni ng /
Non-critical
Cause: The controller battery charge
is weak.
Action: As the charge weakens, the
charger should automatically
recharge the battery. If the battery
has reached its recharge limit, replace
the battery pack. Monitor the battery
to make sure that it recharges
successfully. If the battery does not
recharge, replace the battery pack.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2100
1153
2247 The controller
battery is
charging.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: 2358.
Related Alert Number: None.
LRA Number: None.
1151
2248 The controller
battery is
executing a
Learn cycle.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2249 The physical
disk Clear
operation has
started.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
2251 The physical
disk blink has
initiated.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
2252 The physical
disk blink has
ceased.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers
Vue de la page 105