90 Storage Management Message Reference
2145 Controller
battery low
Warni ng /
Non-critical
Cause: The controller battery charge
is low.
Action: Recondition the battery. See
the online help for more information
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2100
1153
2146 Bad block
replacement
error
Warni ng /
Non-critical
Cause: A portion of a physical disk is
damaged.
Action: See the Dell OpenManage
Server Administrator Storage
Management online help or the
Dell OpenManage Server
Administrator Storage Management
User's Guide for more information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2147 Bad block
sense
error
Warni ng /
Non-critical
Cause: A portion of a physical disk is
damaged.
Action: See the Dell OpenManage
Server Administrator Storage
Management online help for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2148 Bad block
medium error
Warni ng /
Non-critical
Cause: A portion of a physical disk is
damaged.
Action: See the Dell OpenManage
Server Administrator Storage
Management online help for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2149 Bad block
extended sense
error
Warni ng /
Non-critical
Cause: A portion of a physical disk is
damaged.
Action: See the Dell OpenManage
Server Administrator Storage
Management online help for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2150 Bad block
extended
medium error
Warni ng /
Non-critical
Cause: A portion of a physical disk is
damaged.
Action: See the Dell OpenManage
Server Administrator Storage
Management online help for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753