122 Storage Management Message Reference
2319 Single-bit
ECC error.
The DIMM is
degrading.
Warni ng /
Non-critical
Cause: The DIMM is beginning to
malfunction.
Action: Replace the DIMM to avoid
data loss or data corruption. The
DIMM is a part of the controller
battery pack. See your hardware
documentation for information on
replacing the DIMM.
Clear Alert Number: None.
Related Alert Number: 2320
LRA Number: 2060
753
2320 Single-bit
ECC error.
The DIMM is
critically
degraded.
Critical /
Failure /
Error
Cause: The DIMM is
malfunctioning. Data loss or data
corruption may be imminent.
Action: Replace the DIMM
immediately to avoid data loss or data
corruption. The DIMM is a part of
the controller battery pack. See your
hardware documentation for
information on replacing the DIMM.
Clear Alert Number: None.
Related Alert Number: 2321
LRA Number: 2061
754
2321 Single-bit
ECC error.
The DIMM is
critically
degraded.
There will be
no further
reporting.
Critical /
Failure /
Error
Cause: The DIMM is
malfunctioning. Data loss or data
corruption is imminent. The DIMM
must be replaced immediately. No
further alerts will be generated.
Action: Replace the DIMM
immediately. The DIMM is a part of
the controller battery pack. See your
hardware documentation for
information on replacing the DIMM.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2061
754
2322 The DC power
supply is
switched off.
Critical /
Failure /
Error
Cause: The power supply unit is
switched off. Either a user switched
off the power supply unit or it is
defective.
Action: Check if the power switch is
turned off. If it is turned off, turn it
on. If the problem persists, check if
the power cord is attached and
functional. If the problem is still not
corrected or if the power switch is
already turned on, replace the power
supply unit.
Clear Alert Number: 2323.
Related Alert Number: None.
LRA Number: 2091
1004
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP