16 Event Message Reference
1052 Temperature sensor returned
to a normal value
Sensor location:
<Location in
chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Information A temperature sensor on the backplane
board, system board, or drive carrier in the
specified system returned to a valid range
after crossing a failure threshold. The
sensor location, chassis location, previous
state, and temperature sensor value
are provided.
1053 Temperature sensor detected
a warning value
Sensor location:
<Location in
chassis>
Chassis location:
<Name of
chassis>
Previous state was:
<State>
If sensor type is not discrete:
Temperature sensor value (in
degrees Celsius):
<Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Warning A temperature sensor on the backplane
board, system board, CPU, or drive carrier
in the specified system exceeded its
warning threshold. The sensor location,
chassis location, previous state, and
temperature sensor value are provided.
Table 2-2. Temperature Sensor Messages (continued)
Event ID Description Severity Cause