96 omconfig: Managing Components Using the Instrumentation Service
leds P, A Specifies when to flash a
chassis fault LED or chassis
identification LED, and
allows you to clear the LED
for the system's hard drive.
memorymode A Enables or disables the
spare bank, mirroring, raid,
and Double Device Data
Correction (DDDC)
memory modes, and also
specify which mode to use.
pwrmanagement P, A Allows you to choose
between maximum
performance with minimal
power and optimized
performance of the system.
pwrmonitoring P, A Configures power
consumption information
and thresholds.
remoteaccess A Configures remote access
information.
temps P, A Sets warning threshold
values to default or a
specific value.
NOTE: You cannot change
threshold values on ESM3
and PowerEdge
x
8
xx
systems.
Table 4-2. omconfig Command Level 1, Level 2, and Level 3