Dell OpenManage Server Administrator Version 7.0 Manuel d'utilisateur Page 99

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 302
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 98
omconfig: Managing Components Using the Instrumentation Service 99
attribute=
conredirect
setting=enabled |
disabled
enabled: Redirects the BIOS screen over
Serial Port 1. Keyboard and text output
are redirected over Serial Port 2.
disabled: Turns off the BIOS console
redirection.
attribute=crab setting=enabled |
disabled
enabled: Enables BIOS console
redirection after system reboot.
disabled: Disables BIOS console
redirection.
NOTE: The command crab is valid for Dell
PowerEdge x9xx systems only.
attribute=cpuc1e setting=enabled |
disabled
enabled: Enables processor C1-E after
system reboot.
disabled: Disables processor C1-E after
system reboot.
attribute=cpuht setting=enabled |
disabled
enabled: Enables logical processor
hyperthreading.
disabled: Disables logical processor
hyperthreading.
attribute=cpuvt setting=enabled |
disabled
enabled: Enables virtualization.
disabled: Disables virtualization.
Table 4-3. BIOS Setup Settings on systems prior to PowerEdge
yx2x
systems
name=value pair 1
attribute=
name=value pair 2
setting=
Description
Vue de la page 98
1 2 ... 94 95 96 97 98 99 100 101 102 103 104 ... 301 302

Commentaires sur ces manuels

Pas de commentaire